The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
Deep surgical site infection (SSI) is common after lower limb fracture. We compared the diagnosis of deep SSI using alternative methods of data collection and examined the agreement of clinical photography and in-person clinical assessment by the Centers for Disease Control and Prevention (CDC) criteria after lower limb fracture surgery. Data from two large, UK-based multicentre randomized controlled major trauma trials investigating SSI and wound healing after surgical repair of open lower limb fractures that could not be primarily closed (UK WOLLF), and surgical incisions for fractures that were primarily closed (UK WHiST), were examined. Trial interventions were standard wound care management and negative pressure wound therapy after initial surgical debridement. Wound outcomes were collected from 30 days to six weeks. We compared the level of agreement between wound photography and clinical assessment of CDC-defined SSI. We are also assessed the level of agreement between blinded independent assessors of the photographs.Aims
Methods
It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open wounds. There has been a recent shift in this paradigm towards negative pressure wound therapy (NPWT). The aim of this study was to compare the clinical outcomes in patients with open tibial fractures receiving standard dressing versus NPWT. This multicentre randomized controlled trial was approved by the ethical review board of a public sector tertiary care institute. Wounds were graded using Gustilo-Anderson (GA) classification, and patients with GA-II to III-C were included in the study. To be eligible, the patient had to present within 72 hours of the injury. The primary outcome of the study was patient-reported Disability Rating Index (DRI) at 12 months. Secondary outcomes included quality of life assessment using 12-Item Short-Form Health Survey questionnaire (SF-12), wound infection rates at six weeks and nonunion rates at 12 months. Logistic regression analysis and independent-samples Aims
Methods
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
The best time for definitive orthopaedic care is often unclear
in patients with multiple injuries. The objective of this study
was make a prospective assessment of the safety of our early appropriate
care (EAC) strategy and to evaluate the potential benefit of additional
laboratory data to determine readiness for surgery. A cohort of 335 patients with fractures of the pelvis, acetabulum,
femur, or spine were included. Patients underwent definitive fixation
within 36 hours if one of the following three parameters were met:
lactate <
4.0 mmol/L; pH ≥ 7.25; or base excess (BE) ≥ -5.5 mmol/L.
If all three parameters were met, resuscitation was designated full
protocol resuscitation (FPR). If less than all three parameters
were met, it was designated an incomplete protocol resuscitation
(IPR). Complications were assessed by an independent adjudication
committee and included infection; sepsis; PE/DVT; organ failure;
pneumonia, and acute respiratory distress syndrome (ARDS). Aims
Patients and Methods
This article presents a unified clinical theory
that links established facts about the physiology of bone and homeostasis,
with those involved in the healing of fractures and the development
of nonunion. The key to this theory is the concept that the tissue
that forms in and around a fracture should be considered a specific
functional entity. This ‘bone-healing unit’ produces a physiological
response to its biological and mechanical environment, which leads
to the normal healing of bone. This tissue responds to mechanical
forces and functions according to Wolff’s law, Perren’s strain theory
and Frost’s concept of the “mechanostat”. In response to the local
mechanical environment, the bone-healing unit normally changes with
time, producing different tissues that can tolerate various levels
of strain. The normal result is the formation of bone that bridges
the fracture – healing by callus. Nonunion occurs when the bone-healing
unit fails either due to mechanical or biological problems or a
combination of both. In clinical practice, the majority of nonunions
are due to mechanical problems with instability, resulting in too
much strain at the fracture site. In most nonunions, there is an
intact bone-healing unit. We suggest that this maintains its biological
potential to heal, but fails to function due to the mechanical conditions.
The theory predicts the healing pattern of multifragmentary fractures
and the observed morphological characteristics of different nonunions.
It suggests that the majority of nonunions will heal if the correct
mechanical environment is produced by surgery, without the need
for biological adjuncts such as autologous bone graft. Cite this article:
Aims. Although infrequent, a fracture of the cuboid can lead to significant
disruption of the integrity of the midfoot and its function. The
purpose of this study was to classify the pattern of fractures of
the cuboid, relate them to the mechanism of injury and suggest methods
of managing them. Patients and Methods. We performed a retrospective review of patients with radiologically
reported cuboid fractures. Fractures were grouped according to commonly
occurring patterns of injury. A total of 192 fractures in 188 patients
were included. They were classified into five patterns of injury. Results. Type 1 fractures (93 fractures, 48.4%) are simple avulsion injuries
involving the capsule of the calcaneo-cuboid joint. Type 2 fractures
(25 fractures, 13%) are isolated extra-articular injuries involving
the body of the cuboid. Type 3 injuries (13 factures, 6.8%) are
intra-articular fractures solely within the body of the cuboid.
Type 4 fractures (35 fractures, 18.2%) are associated with disruption
of the midfoot and tarsometatarsal injuries. Type 5 fractures (26 fractures,
13.5%) occur in conjunction with disruption of the mid-tarsal joint
and either crushing of the lateral column alone or of both medial
and lateral columns. Fractures with significant articular disruption or with loss
of length of the lateral column underwent fixation. This involved
either internal fixation to restore the anatomy of the cuboid and/or
restoration of the length of the columns with bridging constructs
using
We compared early post-operative rates of wound
infection in HIV-positive and -negative patients presenting with open
tibial fractures managed with surgical fixation. The wounds of 84 patients (85 fractures), 28 of whom were HIV
positive and 56 were HIV negative, were assessed for signs of infection
using the ASEPIS wound score. There were 19 women and 65 men with
a mean age of 34.8 years. A total of 57 fractures (17 HIV-positive The study does not support the hypothesis that HIV significantly
increases the rate of early wound or pin-site infection in open
tibial fractures. We would therefore suggest that a patient’s HIV
status should not alter the management of open tibial fractures
in patients who have a CD4 count >
350 cells/μl. Cite this article:
We report a prospective single-blind controlled
study of the incidence of early wound infection after internal fixation for
trauma in 609 patients, of whom 132 were HIV-positive. Wounds were
assessed for healing using the ASEPSIS score. There was no significant
difference in the rate of infection between HIV-positive and HIV-negative
patients undergoing clean surgery (4.2% We conclude that clean implant surgery in HIV-positive patients
is safe, with no need for additional prophylaxis.
There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.
Between June 1999 and May 2003 we undertook direct primary closure of the skin wounds of 173 patients with Gustilo and Anderson grade-IIIA and grade-IIIB open fractures. These patients were selected from a consecutive group of 557 with type-III injuries presenting during this time. Strict criteria for inclusion in the study included debridement within 12 hours of injury, no sewage or organic contamination, no skin loss either primarily or secondarily during debridement, a Ganga Hospital open injury skin score of 1 or 2 with a total score of ten or less, the presence of bleeding skin margins, the ability to approximate wound edges without tension and the absence of peripheral vascular disease. In addition, patients with polytrauma were excluded. At a mean follow-up of 6.2 years (5 to 7), the outcome was excellent in 150 (86.7%), good in 11 (6.4%) and poor in 12 (6.9%). A total of 33 complications occurred in 23 patients including superficial infection in 11, deep infection in five and the requirement for a secondary skin flap in three. Six patients developed nonunion requiring further surgery, one of whom declined additional measures to treat an established infected nonunion. Immediate skin closure when performed selectively with the above indications proved to be a safe procedure.
We reviewed the clinical details and radiographs of 52 patients with ballistic fractures of the femur admitted to the International Committee of the Red Cross Hospital in Kenya (Lopiding), who had sustained injuries in neighbouring Sudan. In all cases there had been a significant delay in the initial surgery (>
24 hours), and all patients were managed without stabilisation of the fracture by
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.
We reviewed 78 femoral and tibial nonunions treated between January 1992 and December 2003. Of these, we classified 41 in 40 patients as complex cases because of infection (22), bone loss (6) or failed previous surgery (13). The complex cases were all treated with Ilizarov frames. At a mean time of 14.1 months (4 to 38), 39 had healed successfully. Using the Association for the Study and Application of the Methods of Ilizarov scoring system we obtained 17 excellent, 14 good, four fair and six poor bone results. The functional results were excellent in 14 patients, good in 14, fair in two and poor in two. A total of six patients were lost to follow-up and two had amputations so were not evaluated for final functional assessment. All but two patients were very satisfied with the results. The average cost of treatment to the treating hospital was approximately £30 000 per patient. We suggest that early referral to a tertiary centre could reduce the morbidity and prolonged time off work for these patients. The results justify the expense, but the National Health Service needs to make financial provision for the reconstruction of this type of complex nonunion.
We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight. The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation.
We report the incidence and location of deep-vein thrombosis in 312 patients who had sustained high-energy, skeletal trauma. They were investigated using magnetic resonance venography and Duplex ultrasound. Despite thromboprophylaxis, 36 (11.5%) developed venous thromboembolic disease with an incidence of 10% in those with non-pelvic trauma and 12.2% in the group with pelvic trauma. Of patients who developed deep-vein thrombosis, 13 of 27 in the pelvic group (48%) and only one of nine in the non-pelvic group (11%) had a definite pelvic deep-vein thrombosis. When compared with magnetic resonance venography, ultrasound had a false-negative rate of 77% in diagnosing pelvic deep-vein thrombosis. Its value in the pelvis was limited, although it was more accurate than magnetic resonance venography in diagnosing clots in the lower limbs. Additional screening may be needed to detect pelvic deep-vein thrombosis in patients with pelvic or acetabular fractures.