Biopsy of the periprosthetic tissue is an important diagnostic tool for prosthetic joint infection (PJI) as it enables the detection of the responsible microorganism with its sensitivity to antibiotics. We aimed to investigate how often the bacteria identified in the tissue analysis differed between samples obtained from preoperative biopsy and intraoperative revision surgery in cases of late PJI; and whether there was a therapeutic consequence. A total of 508 patients who required revision surgery of total hip arthroplasty (THA) (n = 231) or total knee arthroplasty (TKA) (n = 277) because of component loosening underwent biopsy before revision surgery. The tissue samples collected at biopsy and during revision surgery were analyzed according to the criteria of the Musculoskeletal Infection Society (MSIS).Aims
Methods
Increasing innovation in rapid prototyping (RP)
and additive manufacturing (AM), also known as 3D printing, is bringing
about major changes in translational surgical research. This review describes the current position in the use of additive
manufacturing in orthopaedic surgery. Cite this article:
The diagnosis of periprosthetic joint infection (PJI) remains
demanding due to limitations of all the available diagnostic tests.
The synovial fluid marker, α-defensin, is a promising adjunct for
the assessment of potential PJI. The purpose of this study was to
investigate the qualitative assessment of α-defensin, using Synovasure
to detect or exclude periprosthetic infection in total joint arthroplasty. We studied 50 patients (28 women, 22 men, mean age 65 years;
20 to 89) with a clinical indication for revision arthroplasty who
met the inclusion criteria of this prospective diagnostic study.
The presence of α-defensin was determined using the qualitative
Synovasure test and compared with standard diagnostic methods for
PJI. Based on modified Musculoskeletal Infection Society (MSIS)
criteria, 13 cases were categorised as septic and 36 as aseptic revisions.
One test was inconclusive.Aims
Patients and Methods
Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV.Objectives
Materials and Methods
We wanted to investigate regional variations in the organisms
reported to be causing peri-prosthetic infections and to report
on prophylaxis regimens currently in use across England. Analysis of data routinely collected by Public Health England’s
(PHE) national surgical site infection database on elective primary
hip and knee arthroplasty procedures between April 2010 and March
2013 to investigate regional variations in causative organisms.
A separate national survey of 145 hospital Trusts (groups of hospitals
under local management) in England routinely performing primary
hip and/or knee arthroplasty was carried out by standard email questionnaire.Objectives
Methods
We evaluated the duration of hospitalisation,
occurrence of infections, hip dislocations, revisions, and mortality following
primary hip and knee replacement in 857 patients with Parkinson’s
disease and compared them with 2571 matched control patients. The
data were collected from comprehensive nationwide Finnish health
registers. The mean follow-up was six years (1 to 13). The patients
with Parkinson’s disease had a longer mean length of stay (21 days
[1 to 365] Cite this article:
We performed a meta-analysis of modern total
joint replacement (TJR) to determine the post-operative mortality and
the cause of death using different thromboprophylactic regimens
as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent
anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran,
fondaparinux or rivaroxaban); 3) Potent anticoagulation combined
(PAC) with regional anaesthesia and/or pneumatic compression devices
(PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia
and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional
anaesthesia, PCDs and aspirin in low-risk patients. Cause of death
was classified as autopsy proven, clinically certain or unknown.
Deaths were grouped into cardiopulmonary excluding pulmonary embolism
(PE), PE, bleeding-related, gastrointestinal, central nervous system,
and others (miscellaneous). Meta-analysis based on fixed effects
or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths).
The mortality was lowest in the MM (0.2%) and WC (0.2%) groups.
The most frequent cause of death was cardiopulmonary (47.9%), followed
by PE (25.4%) and bleeding (8.9%). The proportion of deaths due
to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%;
PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher
in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%;
PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce
the overall mortality or the proportion of deaths due to PE.
Survival analysis is an important tool for assessing the outcome of total joint replacement. The Kaplan-Meier method is used to estimate the incidence of revision of a prosthesis over time, but does not account appropriately for competing events which preclude revision. In the presence of competing death, this method will lead to statistical bias and the curve will lose its interpretability. A valid comparison of survival results between studies using the method is impossible without accounting for different rates of competing events. An alternative and easily applicable approach, the cumulative incidence of competing risk, is proposed. Using three simulated data sets and realistic data from a cohort of 406 consecutive cementless total hip prostheses, followed up for a minimum of ten years, both approaches were compared and the magnitude of potential bias was highlighted. The Kaplan-Meier method overestimated the incidence of revision by almost 4% (60% relative difference) in the simulations and more than 1% (31.3% relative difference) in the realistic data set. The cumulative incidence of competing risk approach allows for appropriate accounting of competing risk and, as such, offers an improved ability to compare survival results across studies.
A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems. Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear. We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis.