header advert
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims

Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue.

Methods

Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 606 - 610
1 May 2020
Nicholson JA Slader B Martindale A Mckie S Robinson CM

Aims

The primary aim of this study was to evaluate the efficacy of distension arthrography in the treatment of adhesive capsulitis of the shoulder. The secondary aim was to assess which patient and procedural factors predicted the recurrence of symptoms after the procedure.

Methods

All patients referred to our shoulder clinic over a ten-year period, between 2008 and 2018, with a clinical diagnosis of capsulitis and symptoms persisting for more than six months, were offered treatment with a distension arthrogram. All procedures were performed by one of five musculoskeletal radiologists, with a combination of steroid, local anaesthetic, and a distention volume of 10 ml, 30 ml, or 50 ml. Patient demographics, procedural details, recurrence of symptoms, and the need for further intervention were evaluated.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 346 - 351
1 Mar 2018
Goodall R Claireaux H Hill J Wilson E Monsell F BOAST 11 Collaborative Tarassoli P

Aims

Supracondylar fractures are the most frequently occurring paediatric fractures about the elbow and may be associated with a neurovascular injury. The British Orthopaedic Association Standards for Trauma 11 (BOAST 11) guidelines describe best practice for supracondylar fracture management. This study aimed to assess whether emergency departments in the United Kingdom adhere to BOAST 11 standard 1: a documented assessment, performed on presentation, must include the status of the radial pulse, digital capillary refill time, and the individual function of the radial, median (including the anterior interosseous), and ulnar nerves.

Materials and Methods

Stage 1: We conducted a multicentre, retrospective audit of adherence to BOAST 11 standard 1. Data were collected from eight hospitals in the United Kingdom. A total of 433 children with Gartland type 2 or 3 supracondylar fractures were eligible for inclusion. A centrally created data collection sheet was used to guide objective analysis of whether BOAST 11 standard 1 was adhered to. Stage 2: We created a quality improvement proforma for use in emergency departments. This was piloted in one of the hospitals used in the primary audit and was re-audited using equivalent methodology. In all, 102 patients presenting between January 2016 and July 2017 were eligible for inclusion in the re-audit.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1515 - 1519
1 Nov 2017
Saltzman BM Mayo BC Bohl DD Frank RM Cole BJ Verma NN Nicholson GP Romeo AA

Aims

To determine the incidence and timing of post-operative fevers following shoulder arthroplasty and the resulting investigations performed.

Patients and Methods

A retrospective review was conducted of all patients undergoing shoulder arthroplasty over a nine-year period. The charts of all patients with a post-operative fever (≥ 38.6°C) were reviewed and the results of all investigations were analysed.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1073 - 1079
1 Aug 2017
Pauzenberger L Domej MA Heuberer PR Hexel M Grieb A Laky B Blasl J Anderl W

Aims. The purpose of the present study was to evaluate the impact of intravenous tranexamic acid on the reduction of blood loss, transfusion rate, and early post-operative clinical outcome in total shoulder arthroplasty. Patients and Methods. A randomised, placebo-controlled trial which included 54 patients undergoing unilateral primary stemless anatomical or stemmed reverse total shoulder arthroplasty was undertaken. Patients received either 100 ml saline (placebo, n = 27), or 100 ml saline together with 1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to skin incision and during wound closure. Peri-operative blood loss via an intra-articular drain was recorded and total blood loss was calculated. The post-operative transfusion rate was documented. Assessment of early clinical parameters included the visual analogue scale for pain (VAS), documentation of haematoma formation and adverse events. Results. Mean peri-operative blood drainage (placebo: 170 ml versus TXA: 50 ml, p = 0.001) and calculated mean total blood loss (placebo: 1248.2 ml versus TXA: 871.0 ml, p = 0.009) were significantly lower in the TXA group. No transfusions were necessary during the study period in either group. Mean VAS for pain significantly decreased from pre-operative (VAS 7) to the early post-operative period (VAS 1.7, p < 0.001). Significant differences regarding mean post-operative pain between placebo (VAS 2.0) and TXA (VAS 1.3) were detected (p = 0.05). The occurrence of haematomas was significantly more frequent in the placebo (59.3%, n = 16) than in the TXA group (25.9%, n = 6, p = 0.027). Whereas only mild haematomas developed in the TXA group, in the placebo group a total of 22.2% (n = 6) developed either moderate or severe haematomas. No adverse events associated with administration of TXA occurred. Conclusion. Intravenous administration of TXA successfully reduced mean peri-operative blood drainage, total estimated blood loss, pain during the first post-operative days, and haematoma formation in total shoulder arthroplasty. Cite this article: Bone Joint J 2017;99-B:1073–9


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1208 - 1214
1 Sep 2016
Cowling PD Akhtar MA Liow RYL

Objectives

A variety of operative techniques have been described as under the term ‘Bristow-Latarjet’ procedure. This review aims to define the original procedure, and compare the variation in techniques described in the literature, assessing any effect on clinical outcomes.

Materials and Methods

A systematic review of 24 studies was performed to compare specific steps of the technique (coracoid osteotomy site, subscapularis approach, orientation and position of coracoid graft fixation and fixation method, additional labral and capsular repair) and detect any effect this variability had on outcomes.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.