Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1013 - 1015
1 Sep 2004
Kim JS Baek GH Chung MS Yoon PW

We performed nine metatarsal and three proximal phalangeal lengthenings in five patients with congenital brachymetatarsia of the first and one or two other metatarsal bones, by a one-stage combined shortening and lengthening procedure using intercalcary autogenous bone grafts from adjacent shortened metatarsal bones. Instead of the isolated lengthening of the first and the other metatarsal bones, we shortened the adjacent normal metatarsal and used the excised bone to lengthen the short toes, except for the great toe, to restore the normal parabola. One skin incision was used. All the operations were performed bilaterally and the patients were followed up for a mean period of 69.5 months (29 to 107). They all regained a nearly normal parabola and were satisfied with the cosmetic results. Our technique is straightforward and produces good cosmetic results. Satisfactory, bony union is achieved, morbidity is low, and no additional surgery is required for the removal of metal implants