Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 396 - 403
1 Mar 2018
Messner J Johnson L Taylor DM Harwood P Britten S Foster P

Aims

The aim of this study was to report the clinical, functional and radiological outcomes of children and adolescents with tibial fractures treated using the Ilizarov method.

Patients and Methods

Between 2013 and 2016 a total of 74 children with 75 tibial fractures underwent treatment at our major trauma centre using an Ilizarov frame. Demographic and clinical information from a prospective database was supplemented by routine functional and psychological assessment and a retrospective review of the notes and radiographs.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 544 - 553
1 Apr 2017
Nandra RS Wu F Gaffey A Bache CE

Aims

Following the introduction of national standards in 2009, most major paediatric trauma is now triaged to specialist units offering combined orthopaedic and plastic surgical expertise. We investigated the management of open tibia fractures at a paediatric trauma centre, primarily reporting the risk of infection and rate of union.

Patients and Methods

A retrospective review was performed on 61 children who between 2007 and 2015 presented with an open tibia fracture. Their mean age was nine years (2 to 16) and the median follow-up was ten months (interquartile range 5 to 18). Management involved IV antibiotics, early debridement and combined treatment of the skeletal and soft-tissue injuries in line with standards proposed by the British Orthopaedic Association.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1283 - 1288
1 Sep 2016
Abdelazeem AH Beder FK Abdel Karim MM Abdelazeem H Abdel-Ghani H

Aims

This study analysed the clinical and radiological outcome of anatomical reduction of a moderate or severe stable slipped capital femoral epiphysis (SCFE) treated by subcapital osteotomy (a modified Dunn osteotomy) through the surgical approach described by Ganz.

Patients and Methods

We prospectively studied 31 patients (32 hips; 16 females and five males; mean age 14.3 years) with SCFE. On the Southwick classification, ten were of moderate severity (head-shaft angle > 30° to 60°) and 22 were severe (head-shaft angle > 60°). Each underwent open reduction and internal fixation using an intracapsular osteotomy through the physeal growth plate after safe surgical hip dislocation. Unlike the conventional procedure, 25 hips did not need an osteotomy of the apophysis of the great trochanter and were managed using an extended retinacular posterior flap.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 855 - 860
1 Jun 2013
Gottliebsen M Møller-Madsen B Stødkilde-Jørgensen H Rahbek O

Permanent growth arrest of the longer bone is an option in the treatment of minor leg-length discrepancies. The use of a tension band plating technique to produce a temporary epiphysiodesis is appealing as it avoids the need for accurate timing of the procedure in relation to remaining growth. We performed an animal study to establish if control of growth in a long bone is possible with tension band plating. Animals (pigs) were randomised to temporary epiphysiodesis on either the right or left tibia. Implants were removed after ten weeks. Both tibiae were examined using MRI at baseline, and after ten and 15 weeks. The median interphyseal distance was significantly shorter on the treated tibiae after both ten weeks (p = 0.04) and 15 weeks (p = 0.04). On T1-weighted images the metaphyseal water content was significantly reduced after ten weeks on the treated side (p = 0.04) but returned to values comparable with the untreated side at 15 weeks (p = 0.14). Return of growth was observed in all animals after removal of implants.

Temporary epiphysiodesis can be obtained using tension band plating. The technique is not yet in common clinical practice but might avoid the need for the accurate timing of epiphysiodesis.

Cite this article: Bone Joint J 2013;95-B:855–60.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 833 - 838
1 Jun 2011
Huber H Dora C Ramseier LE Buck F Dierauer S

Between June 2001 and November 2008 a modified Dunn osteotomy with a surgical hip dislocation was performed in 30 hips in 28 patients with slipped capital femoral epiphysis. Complications and clinical and radiological outcomes after a mean follow-up of 3.8 years (1.0 to 8.5) were documented. Subjective outcome was assessed using the Harris hip score and the Western Ontario and McMaster Universities osteoarthritis index questionnaire.

Anatomical or near-anatomical reduction was achieved in all cases. The epiphysis in one hip showed no perfusion intra-operatively and developed avascular necrosis. There was an excellent outcome in 28 hips. Failure of the implants with a need for revision surgery occurred in four hips.

Anatomical reduction can be achieved by this technique, with a low risk of avascular necrosis. Cautious follow-up is necessary in order to avoid implant failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 273 - 276
1 Feb 2010
Ballal MS Bruce CE Nayagam S

A total of 25 children (37 legs and 51 segments) with coronal plane deformities around the knee were treated with the extraperiosteal application of a flexible two-hole plate and screws. The mean age was 11.6 years (5.5 to 14.9), the median angle of deformity treated was 8.3° and mean time for correction was 16.1 months (7 to 37.3). There was a mean rate of correction of 0.7° per month in the femur (0.3° to 1.5°), 0.5° per month in the tibia (0.1° to 0.9°) and 1.2° per month (0.1° to 2.2°) if femur and tibia were treated concurrently. Correction was faster if the child was under 10 years of age (p = 0.05). The patients were reviewed between six and 32 months after plate removal. One child had a rebound deformity but no permanent physeal tethers were encountered.

The guided growth technique, as performed using a flexible titanium plate, is simple and safe for treating periarticular deformities of the leg.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1228 - 1233
1 Sep 2008
Ramachandran M Skaggs DL Crawford HA Eastwood DM Lalonde FD Vitale MG Do TT Kay RM

The aim of this retrospective multicentre study was to report the continued occurrence of compartment syndrome secondary to paediatric supracondylar humeral fractures in the period 1995 to 2005. The inclusion criteria were children with a closed, low-energy supracondylar fracture with no associated fractures or vascular compromise, who subsequently developed compartment syndrome. There were 11 patients (seven girls and four boys) identified from eight hospitals in three countries. Ten patients with severe elbow swelling documented at presentation had a mean delay before surgery of 22 hours (6 to 64). One patient without severe swelling documented at presentation suffered arterial entrapment following reduction, with a subsequent compartment syndrome requiring fasciotomy 25 hours after the index procedure.

This series is noteworthy, as all patients had low-energy injuries and presented with an intact radial pulse. Significant swelling at presentation and delay in fracture reduction may be important warning signs for the development of a compartment syndrome in children with supracondylar fractures of the humerus.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 377 - 381
1 Mar 2008
Canavese F Gupta S Krajbich JI Emara KM

Our aim was to review the efficacy of the wound vacuum-assisted closure (VAC) system in the treatment of deep infection after extensive instrumentation and fusion for spinal deformity in children and adolescents. A total of 14 patients with early deep spinal infection were treated using this technique. Of these, 12 had neuromuscular or syndromic problems. Clinical and laboratory data were reviewed. The mean follow-up was 44 months (24 to 72). All wounds healed. Two patients required plastic surgery to speed up the process. In no patient was the hardware removed and there was no loss of correction or recurrent infection. We believe that the wound VAC system is a useful tool in the armamentarium of the spinal surgeon dealing with patients susceptible to wound infections, especially those with neuromuscular diseases. It allows for the retention of the instrumentation and the maintenance of spinal correction. It is reliable and easy to use


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 231 - 235
1 Feb 2005
Kirkos JM Kyrkos MJ Kapetanos GA Haritidis JH

We describe the long-term results in ten patients with obstetric brachial plexus palsy of anterior shoulder release combined with transfer of teres major and latissimus dorsi posteriorly and laterally to allow them to act as external rotators. Eight patients had a lesion of the superior trunk and two some involvement of the entire brachial plexus. The mean age at operation was six years, and the mean follow-up was 30 years.

Before operation, the patients were unable actively to rotate the arm externally beyond neutral, although this movement was passively normal. All showed decreased strength of the external rotator, but had normal strength of the internal rotator muscles. Radiologically, no severe bony changes were seen in the glenohumeral joint.

No clinically detectable improvement of active abduction was noted in any patient. The mean active external rotation after operation was 36.5°. This was maintained for a mean of ten years, and then deteriorated in eight patients. At the latest follow-up the mean active external rotation was 10.5°.

The early satisfactory results of the procedure were not maintained. In the long term there was loss of active external rotation, possibly because of gradual degeneration of the transferred muscles, contracture of the surrounding soft tissues and degenerative changes in the glenohumeral joint.