To develop and internally validate a preoperative clinical prediction model for acute adjacent vertebral fracture (AVF) after vertebral augmentation to support preoperative decision-making, named the after vertebral augmentation (AVA) score. In this prognostic study, a multicentre, retrospective single-level vertebral augmentation cohort of 377 patients from six Japanese hospitals was used to derive an AVF prediction model. Backward stepwise selection (p < 0.05) was used to select preoperative clinical and imaging predictors for acute AVF after vertebral augmentation for up to one month, from 14 predictors. We assigned a score to each selected variable based on the regression coefficient and developed the AVA scoring system. We evaluated sensitivity and specificity for each cut-off, area under the curve (AUC), and calibration as diagnostic performance. Internal validation was conducted using bootstrapping to correct the optimism.Aims
Methods
Objectives. Although
The widespread use of MRI has revolutionised
the diagnostic process for spinal disorders. A typical protocol
for spinal MRI includes T1 and T2 weighted sequences in both axial
and sagittal planes. While such an imaging protocol is appropriate
to detect pathological processes in the vast majority of patients,
a number of additional sequences and advanced techniques are emerging.
The purpose of the article is to discuss both established techniques
that are gaining popularity in the field of spinal imaging and to
introduce some of the more novel ‘advanced’ MRI sequences with examples
to highlight their potential uses. Cite this article:
Percutaneous placement of pedicle screws is a
well-established technique, however, no studies have compared percutaneous
and open placement of screws in the thoracic spine. The aim of this
cadaveric study was to compare the accuracy and safety of these
techniques at the thoracic spinal level. A total of 288 screws were
inserted in 16 (eight cadavers, 144 screws in percutaneous and eight
cadavers, 144 screws in open). Pedicle perforations and fractures
were documented subsequent to wide laminectomy followed by skeletalisation
of the vertebrae. The perforations were classified as grade 0: no
perforation, grade 1: <
2 mm perforation, grade 2: 2 mm to 4
mm perforation and grade 3: >
4 mm perforation. In the percutaneous
group, the perforation rate was 11.1% with 15 (10.4%) grade 1 and
one (0.7%) grade 2 perforations. In the open group, the perforation
rate was 8.3% (12 screws) and all were grade 1. This difference
was not significant (p = 0.45). There were 19 (13.2%) pedicle fractures
in the percutaneous group and 21 (14.6%) in the open group (p =
0.73). In summary, the safety of percutaneous fluoroscopy-guided
pedicle screw placement in the thoracic spine between T4 and T12
is similar to that of the conventional open technique. Cite this article:
We undertook a retrospective study investigating
the accuracy and safety of percutaneous pedicle screws placed under
fluoroscopic guidance in the lumbosacral junction and lumbar spine.
The CT scans of patients were chosen from two centres: European
patients from University Medical Center Hamburg-Eppendorf, Germany,
and Asian patients from the University of Malaya, Malaysia. Screw
perforations were classified into grades 0, 1, 2 and 3. A total
of 880 percutaneous pedicle screws from 203 patients were analysed:
614 screws from 144 European patients and 266 screws from 59 Asian
patients. The mean age of the patients was 58.8 years (16 to 91)
and there were 103 men and 100 women. The total rate of perforation
was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade
3 perforations. The rate of perforation in Europeans was 10.4% and
in Asians was 8.6%, with no significant difference between the two
(p = 0.42). The rate of perforation was the highest in S1 (19.4%)
followed by L5 (14.9%). The accuracy and safety of percutaneous
pedicle screw placement are comparable to those cited in the literature
for the open method of pedicle screw placement. Greater caution
must be taken during the insertion of L5 and S1 percutaneous pedicle
screws owing to their more angulated pedicles, the anatomical variations
in their vertebral bodies and the morphology of the spinal canal
at this location. Cite this article:
We investigated the spinopelvic morphology and
global sagittal balance of patients with a degenerative retrolisthesis
or anterolisthesis. A total of 269 consecutive patients with a degenerative
spondylolisthesis were included in this study. There were 95 men
and 174 women with a mean age of 64.3 years ( A backward slip was found in the upper lumbar levels (mostly
L2 or L3) with an almost equal gender distribution in both the R
and R+A groups. The pelvic incidence and sacral slope of the R group
were significantly lower than those of the A (both p <
0.001)
and R+A groups (both p <
0.001). The lumbar lordosis of the R+A
group was significantly greater than that of the R (p = 0.025) and
A groups (p = 0.014). The C7 plumb line of the R group was located
more posteriorly than that of the A group (p = 0.023), but was no
different from than that of the R+A group (p = 0.422). The location
of C7 plumb line did not differ between the three groups (p = 0.068).
The spinosacral angle of the R group was significantly smaller than
that of the A group (p <
0.001) and R+A group (p <
0.001). Our findings imply that there are two types of degenerative retrolisthesis:
one occurs primarily as a result of degeneration in patients with
low pelvic incidence, and the other occurs secondarily as a compensatory
mechanism in patients with an anterolisthesis and high pelvic incidence. Cite this article:
The purpose of this study was to determine whether
patients with a burst fracture of the thoracolumbar spine treated
by short segment pedicle screw fixation fared better clinically
and radiologically if the affected segment was fused at the same
time. A total of 50 patients were enrolled in a prospective study
and assigned to one of two groups. After the exclusion of three
patients, there were 23 patients in the fusion group and 24 in the
non-fusion group. Follow-up was at a mean of 23.9 months (18 to
30). Functional outcome was evaluated using the Greenough Low Back
Outcome Score. Neurological function was graded using the American
Spinal Injury Association Impairment Scale. Peri-operative blood transfusion requirements and duration of
surgery were significantly higher in the fusion group (p = 0.029
and p <
0.001, respectively). There were no clinical or radiological
differences in outcome between the groups (all outcomes p >
0.05).
The results of this study suggest that adjunctive fusion is unnecessary
when managing patients with a burst fracture of the thoracolumbar
spine with short segment pedicle screw fixation.
The optimal timing of percutaneous vertebroplasty
as treatment for painful osteoporotic vertebral compression fractures
(OVCFs) is still unclear. With the position of
Osteoporotic vertebral compression fractures
(VCFs) are an increasing public health problem. Recently, randomised
controlled trials on the use of kyphoplasty and
Vertebral compression fractures are the most prevalent complication of osteoporosis and percutaneous
We investigated the safety and efficacy of treating osteoporotic vertebral compression fractures with an intravertebral cleft by balloon kyphoplasty. Our study included 27 patients who were treated in this way. The mean follow-up was 38.2 months (24 to 54). The anterior and middle heights of the vertebral body and the kyphotic angle were measured on standing lateral radiographs before surgery, one day after surgery, and at final follow-up. Leakage of cement was determined by CT scans. A visual analogue scale and the Oswestry disability index were chosen to evaluate pain and functional activity. Statistically significant improvements were found between the pre- and post-operative assessments (p <
0.05) but not between the post-operative and final follow-up assessments (p >
0.05). Asymptomatic leakage of cement into the paravertebral vein occurred in one patient, as did leakage into the intervertebral disc in another patient. We suggest that balloon kyphoplasty is a safe and effective minimally invasive procedure for the treatment of osteoporotic vertebral compression fractures with an intravertebral cleft.
This study prospectively compared the efficacy of kyphoplasty using a Jack vertebral dilator and balloon kyphoplasty to treat osteoporotic compression fractures between T10 and L5. Between 2004 and 2009, two groups of 55 patients each underwent vertebral dilator kyphoplasty and balloon kyphoplasty, respectively. Pain, function, the Cobb angle, and the anterior and middle height of the vertebral body were assessed before and after operation. Leakage of bone cement was recorded. The post-operative change in the Cobb angle was significantly greater in the dilator kyphoplasty group than in the balloon kyphoplasty group (−9.51° ( These findings suggest that vertebral dilator kyphoplasty can facilitate better correction of kyphotic deformity and may ultimately be a safer procedure in reducing leakage of bone cement.
Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by
In a prospective study between August 2002 and August 2005, we studied the quantitative clinical and radiological outcome 36 months after percutaneous
Vertebral haemangiomas are usually asymptomatic and discovered fortuitously during imaging. A small proportion may develop variable degrees of pain and neurological deficit. We prospectively studied six patients who underwent eight surgical procedures on 11 vertebral bodies. There were 11 balloon kyphoplasties, six lumbar and five thoracic. The mean follow-up was 22.3 months (12 to 36). The indications for operation were pain in four patients, severe back pain with Frankel grade C paraplegia from cord compression caused by soft-tissue extension from a thoracic vertebral haemangioma in one patient, and acute bleeding causing Frankel grade B paraplegia from an asymptomatic vascular haemangioma in one patient. In four patients the exhibited aggressive vascular features, and two showed lipomatous, non-aggressive, characteristics. One patient who underwent a unilateral balloon kyphoplasty developed a recurrence of symptoms from the non-treated side of the vertebral body which was managed by a further similar procedure. Balloon kyphoplasty was carried out successfully and safely in all patients; four became asymptomatic and two showed considerable improvement. Neurological recovery occurred in all cases but bleeding was greater than normal. To avoid recurrence, complete obliteration of the lesion with bone cement is indicated. For acute bleeding balloon kyphoplasty should be combined with emergency decompressive laminectomy. For intraspinal extension with serious neurological deficit, a combination of balloon kyphoplasty with intralesional alcohol injection is effective.
We present the clinical and radiological results of percutaneous
We have studied 58 patients with pain from osteoporotic vertebral fractures which did not respond to conservative treatment. These were 53 women and five men with a mean age of 72.5 years. They received a nerve-root injection with lidocaine, bupivicaine and DepoMedrol. The mean follow-up period was 13.5 months. The mean pain scores before treatment, at one and six months after treatment and at the final follow-up were 85, 24.9, 14.1, and 17.4, respectively. According to our modified criteria for grading results, six patients were considered to have an excellent result, 42 good and ten fair. A newly developed compression fracture was noted in three patients. There were no complications related to the injection. Our study suggests that nerve-root injections are effective in reducing pain in patients with osteoporotic vertebral fractures and that these patients should be considered for this treatment before percutaneous
We analysed the CT scans and radiographs of 76 vertebrae in 49 patients who underwent