The primary aim of this study was to assess whether patients waiting six months or more for a total hip (THA) or knee (KA) arthroplasty had a deterioration in their health-related quality of life (HRQoL). Secondary aims were to assess changes in frailty and the number of patients living in a state considered to be worse than death (WTD), and factors associated with changes in HRQoL and frailty. This cross-sectional study included 326 patients, 150 males (46.0%) and 176 females (54.0%), with a mean age of 68.6 years (SD 9.8) who were randomly selected from waiting lists at four centres and had been waiting for six months or more (median 13 months, interquartile range 10 to 21) for a primary THA (n = 161) or KA (n = 165). The EuroQol five-dimension questionnaire (EQ-5D) and visual analogue scores (EQ-VAS), Rockwood Clinical Frailty Scale (CFS), and 36-Item Short Form Survey subjective change in HRQoL were assessed at the time and recalled for six months earlier. A state that was WTD was defined as an EQ-5D of less than zero.Aims
Methods
Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed.Aims
Methods
Aims. The aim of this study was to determine the prevalence and characteristics of C-reactive protein (CRP)-negative prosthetic joint infection (PJI) and evaluate the influence of the type of infecting organism on the CRP level. Patients and Methods. A retrospective analysis of all PJIs affecting the hip or knee that were diagnosed in our institution between March 2013 and December 2016 was performed. A total of 215 patients were included. Their mean age was 71 years (. sd. 11) and there were 118 women (55%). The median serum CRP levels were calculated for various species of organism and for patients with acute postoperative, acute haematogenous, and chronic infections. These were compared using the Kruskal–Wallis test, adjusting for multiple comparisons with Dunn’s test. The correlation between the number of positive cultures and serum CRP levels was estimated using
Wear debris released from bearing surfaces has been shown to
provoke negative immune responses in the recipient. Excessive wear
has been linked to early failure of prostheses. Analysis using coordinate
measuring machines (CMMs) can provide estimates of total volumetric
material loss of explanted prostheses and can help to understand
device failure. The accuracy of volumetric testing has been debated,
with some investigators stating that only protocols involving hundreds
of thousands of measurement points are sufficient. We looked to
examine this assumption and to apply the findings to the clinical
arena. We examined the effects on the calculated material loss from
a ceramic femoral head when different CMM scanning parameters were
used. Calculated wear volumes were compared with gold standard gravimetric
tests in a blinded study. Objectives
Methods
Although the Western Ontario and McMaster Universities
(WOMAC) osteoarthritis index was originally developed for the assessment
of non-operative treatment, it is commonly used to evaluate patients
undergoing either total hip (THR) or total knee replacement (TKR).
We assessed the importance of the 17 WOMAC function items from the perspective
of 1198 patients who underwent either THR (n = 704) or TKR (n =
494) in order to develop joint-specific short forms. After these
patients were administered the WOMAC pre-operatively and at three,
six, 12 and 24 months’ follow-up, they were asked to nominate an
item of the function scale that was most important to them. The
items chosen were significantly different between patients undergoing
THR and those undergoing TKR (p <
0.001), and there was a shift
in the priorities after surgery in both groups. Setting a threshold
for prioritised items of ≥ 5% across all follow-up, eight items
were selected for THR and seven for TKR, of which six items were
common to both. The items comprising specific WOMAC-THR and TKR
function short forms were found to be equally responsive compared
with the original WOMAC function form. Cite this article:
Obtaining a balanced flexion gap with correct
femoral component rotation is one of the prerequisites for a successful
outcome after total knee replacement (TKR). Different techniques
for achieving this have been described. In this study we prospectively
compared gap-balancing Both groups systematically reproduced a similar external rotation
of the femoral component relative to the surgical transepicondylar
axis: 2.4°
Patient expectations and their fulfilment are
an important factor in determining patient-reported outcome and satisfaction
of hip (THR) and knee replacement (TKR). The aim of this prospective
cohort study was to examine the expectations of patients undergoing
THR and TKR, and to identify differences in expectations, predictors
of high expectations and the relationship between the fulfilment
of expectations and patient-reported outcome measures. During the
study period, patients who underwent 346 THRs and 323 TKRs completed
an expectation questionnaire, Oxford score and Short-Form 12 (SF-12)
score pre-operatively. At one year post-operatively, the Oxford
score, SF-12, patient satisfaction and expectation fulfilment were
assessed. Univariable and multivariable analysis were performed.
Improvements in mobility and daytime pain were the most important
expectations in both groups. Expectation level did not differ between
THR and TKR. Poor Oxford score, younger age and male gender significantly
predicted high pre-operative expectations (p <
0.001). The level
of pre-operative expectation was not significantly associated with
the fulfilment of expectations or outcome. THR better met the expectations
identified as important by patients. TKR failed to meet expectations
of kneeling, squatting and stair climbing. High fulfilment of expectation
in both THR and TKR was significantly predicted by young age, greater
improvements in Oxford score and high pre-operative mental health
scores. The fulfilment of expectations was highly correlated with satisfaction.
We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value. Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p <
0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.