Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1419 - 1427
3 Oct 2020
Wood D French SR Munir S Kaila R

Aims

Despite the increase in the surgical repair of proximal hamstring tears, there exists a lack of consensus in the optimal timing for surgery. There is also disagreement on how partial tears managed surgically compare with complete tears repaired surgically. This study aims to compare the mid-term functional outcomes in, and operating time required for, complete and partial proximal hamstring avulsions, that are repaired both acutely and chronically.

Methods

This is a prospective series of 156 proximal hamstring surgical repairs, with a mean age of 48.9 years (21.5 to 78). Functional outcomes were assessed preinjury, preoperatively, and postoperatively (six months and minimum three years) using the Sydney Hamstring Origin Rupture Evaluation (SHORE) score. Operating time was recorded for every patient.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 569 - 573
1 May 2014
Sullivan MP McHale KJ Parvizi J Mehta S

Nanotechnology is the study, production and controlled manipulation of materials with a grain size < 100 nm. At this level, the laws of classical mechanics fall away and those of quantum mechanics take over, resulting in unique behaviour of matter in terms of melting point, conductivity and reactivity. Additionally, and likely more significant, as grain size decreases, the ratio of surface area to volume drastically increases, allowing for greater interaction between implants and the surrounding cellular environment. This favourable increase in surface area plays an important role in mesenchymal cell differentiation and ultimately bone–implant interactions.

Basic science and translational research have revealed important potential applications for nanotechnology in orthopaedic surgery, particularly with regard to improving the interaction between implants and host bone. Nanophase materials more closely match the architecture of native trabecular bone, thereby greatly improving the osseo-integration of orthopaedic implants. Nanophase-coated prostheses can also reduce bacterial adhesion more than conventionally surfaced prostheses. Nanophase selenium has shown great promise when used for tumour reconstructions, as has nanophase silver in the management of traumatic wounds. Nanophase silver may significantly improve healing of peripheral nerve injuries, and nanophase gold has powerful anti-inflammatory effects on tendon inflammation.

Considerable advances must be made in our understanding of the potential health risks of production, implantation and wear patterns of nanophase devices before they are approved for clinical use. Their potential, however, is considerable, and is likely to benefit us all in the future.

Cite this article: Bone Joint J 2014; 96-B: 569–73.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 408 - 409
1 Mar 2005
Thomas S Theologis T Wainwright AM

We present simple but effective retractors used in pairs to expose the sciatic notch during Salter innominate osteotomy. We have found them to be useful for a wide range of procedures requiring similar exposure. We present them here in tribute to the memory of the designer Mercer Rang.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 401 - 407
1 Mar 2005
Giannoudis PV Da Costa AA Raman R Mohamed AK Smith RM

Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries. Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome. At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years