Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 890 - 898
1 Jul 2020
Cheung PWH Wong CKH Cheung JPY

Aims

The health-related quality of life (HRQoL) of paediatric patients with orthopaedic conditions and spinal deformity is important, but existing generic tools have their shortcomings. We aim to evaluate the use of Paediatric Quality of Life Inventory (PedsQL) 4.0 generic core scales in the paediatric population with specific comparisons between those with spinal and limb pathologies, and to explore the feasibility of using PedsQL for studying scoliosis patients’ HRQoL.

Methods

Paediatric patients attending a speciality outpatient clinic were recruited through consecutive sampling. Two groups of patients were included: idiopathic scoliosis, and paediatric orthopaedic upper and lower limb condition without scoliosis. Patients were asked to complete PedsQL 4.0 generic core scales, Youth version of 5-level EuroQol-5-dimension questionnaire, and Refined Scoliosis Research Society 22-item (SRS-22r) questionnaire. Statistical analyses included scores comparison between scoliosis and limb pathology patients using independent-samples t-test, and correlation tests of PedsQL and SRS-22r.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 254 - 260
1 Feb 2020
Cheung JPY Cheung PWH

Aims

The aim of this study was to assess whether supine flexibility predicts the likelihood of curve progression in patients with adolescent idiopathic scoliosis (AIS) undergoing brace treatment.

Methods

This was a retrospective analysis of patients with AIS prescribed with an underarm brace between September 2008 to April 2013 and followed up until 18 years of age or required surgery. Patients with structural proximal curves that preclude underarm bracing, those who were lost to follow-up, and those who had poor compliance to bracing (<16 hours a day) were excluded. The major curve Cobb angle, curve type, and location were measured on the pre-brace standing posteroanterior (PA) radiograph, supine whole spine radiograph, initial in-brace standing PA radiograph, and the post-brace weaning standing PA radiograph. Validation of the previous in-brace Cobb angle regression model was performed. The outcome of curve progression post-bracing was tested using a logistic regression model. The supine flexibility cut-off for curve progression was analyzed with receiver operating characteristic curve.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1228 - 1233
1 Sep 2008
Ramachandran M Skaggs DL Crawford HA Eastwood DM Lalonde FD Vitale MG Do TT Kay RM

The aim of this retrospective multicentre study was to report the continued occurrence of compartment syndrome secondary to paediatric supracondylar humeral fractures in the period 1995 to 2005. The inclusion criteria were children with a closed, low-energy supracondylar fracture with no associated fractures or vascular compromise, who subsequently developed compartment syndrome. There were 11 patients (seven girls and four boys) identified from eight hospitals in three countries. Ten patients with severe elbow swelling documented at presentation had a mean delay before surgery of 22 hours (6 to 64). One patient without severe swelling documented at presentation suffered arterial entrapment following reduction, with a subsequent compartment syndrome requiring fasciotomy 25 hours after the index procedure.

This series is noteworthy, as all patients had low-energy injuries and presented with an intact radial pulse. Significant swelling at presentation and delay in fracture reduction may be important warning signs for the development of a compartment syndrome in children with supracondylar fractures of the humerus.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 892 - 897
1 Aug 2004
Pizà G Caja VL González-Viejo MA Navarro A

Pin loosening and infection are inherent complications of external fixation. This study deals with their effects of using either hydroxyapatite (HA)-coated or uncoated external fixation pins in leg-lengthening procedures on patients of short stature. We used HA-coated pins on one side and uncoated pins on the other (randomly determined) in 28 bilateral lengthenings undertaken in 23 patients. A total of 322 pins was used. The mean implantation time was 530 days and the mean lengthening achieved was 78% of initial bone length. Mean extraction torque was 7611.6 Nmm degree. −1. for HA-coated and 85.4 Nmm degree. −1. for uncoated pins (p < 0.001). The rate of pin loosening was 4% (7/ 161) for HA-coated and 80% (129/161) for uncoated pins (p < 0.001). There was no statistically significant difference in the incidence of pin-track infection between the two groups. The use of HA coating appears to be an effective method of reducing the incidence of pin loosening in external fixation with a long implantation time and for mechanically highly stressed procedures such as leg lengthening for short stature


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 307 - 313
1 Mar 1996
Ransford AO Crockard HA Stevens JM Modaghegh S

In 17 patients (eleven males, six females) with Morquio-Brailsford syndrome (mucopolysaccharidosis IV) we have used onlay femoral and tibial autografts placed posteriorly and secured to the laminae of C1 and C2 to obtain satisfactory occipito-C1/C2 posterior fusion. They were immobilised postoperatively in a halo-plaster body jacket for four months. The age at operation varied between three and 28 years. Those with myelopathic symptoms of recent onset made some recovery, but severely myelopathic patients showed little or no recovery.

We advise prophylactic occipitocervical fusion in these patients since the cartilaginous dens is not strong enough to ensure atlanto-axial mechanical stability.