Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential.Aims
Methods
Aims. Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Methods. Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown
Latissimus dorsi tendon transfer (LDTT) is technically
challenging. In order to clarify the local structural anatomy, we undertook
a morphometric study using six complete cadavers (12 shoulders).
Measurements were made from the tendon to the nearby neurovascular
structures with the arm in two positions: flexed and internally
rotated, and adducted in neutral rotation. The tendon was then transferred
and measurements were taken from the edge of the tendon to a reference
point on the humeral head in order to assess the effect of a novel
two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances
between the superior tendon edge and the radial nerve, brachial
artery, axillary nerve and posterior circumflex artery were 30 mm
(26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to
21), respectively. The mean distance between the inferior tendon
edge and the radial nerve, brachial artery and profunda brachii
artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively.
Moving the arm to a neutral position reduced these distances. A
mean of 15 mm (8 to 21) was gained from a standard soft-tissue release,
and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of
this region and the potential for transfer of the latissimus dorsi
tendon. Cite this article:
A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid. The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture. The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.
We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and massive tears were measured using FTIR and compared with 11 uninjured control tendons. All the spectra were classified using standard techniques of multivariate analysis. FTIR readily differentiates between normal and torn tendons, and different sizes of tear. We identified the key discriminating molecules and spectra altered in torn tendons to be carbohydrates/phospholipids (1030 cm−1 to 1200 cm−1), collagen (1300 cm−1 to 1700 cm−1 and 3000 cm−1 to 3350 cm−1) and lipids (2800 cm−1 to 3000 cm−1). Our study has shown that FTIR spectroscopy can identify tears of the rotator cuff of varying size based upon distinguishable chemical and structural features. The onset of a tear is mainly associated with altered structural arrangements of collagen, with changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used peri-operatively to determine the quality of the tendon and the extent of the disease, thus guiding surgical repair.
We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46). The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex. All the patients remained free from pain (p <
0.001) with improvement in function (p <
0.001) and range of movement (p <
0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p <
0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients. This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.
We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery. Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids.
We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the rotator cuff were detected in 32 subjects (7.6%). The prevalence increased with age as follows: 50 to 59 years, 2.1%; 60 to 69 years, 5.7%; and 70 to 79 years, 15%. The mean size of the tear was less than 3 cm and tear localisation was limited to the supraspinatus tendon in most cases (78%). The strength of flexion was reduced significantly in the group with tears (p = 0.01). Asymptomatic tears of the rotator cuff should be regarded as part of the normal ageing process in the elderly but may be less common than hitherto believed.
The lateral ligament complex is the primary constraint to posterolateral rotatory laxity of the elbow, and if it is disrupted during surgery, posterolateral instability may ensue. The Wrightington approach to the head of the radius involves osteotomising the ulnar insertion of this ligament, rather than incising through it as in the classic posterolateral (Kocher) approach. In this biomechanical study of 17 human cadaver elbows, we demonstrate that the surgical approach to the head can influence posterolateral laxity, with the Wrightington approach producing less posterolateral rotatory laxity than the posterolateral approach.
Disorders of the pisotriquetral joint are well recognised as the cause of pain on the ulnar side of the wrist. The joint is not usually examined during routine arthroscopy because it is assumed to have a separate joint cavity to the radiocarpal joint, although there is often a connection between the two. We explored this connection during arthroscopy and in fresh-frozen cadaver wrists and found that in about half of the cases the pisotriquetral joint could be visualised through standard wrist portals. Four different types of connection were observed between the radiocarpal joint and the pisotriquetral joint. They ranged from a complete membrane separating the two, to no membrane at all, with various other types of connection in between. We recommend that inspection of the pisotriquetral joint should be a part of the protocol for routine arthroscopy of the wrist.
This study reviews the predisposing features, the clinical, and laboratory findings at the time of diagnosis and the results of single-stage revision of prosthetic replacement of the elbow for infection. Deep infection occurred in six of 305 (1.9%) primary total elbow replacements. The mean follow-up after revision was 6.8 years (6 months to 16 years) and the mean age at the time of revision was 62.7 years (56 to 74). All six cases with infection had rheumatoid arthritis and had received steroid therapy. The infective organism was