Total elbow replacement can be a valuable option for the treatment of the elbow in haemophilia where there are associated arthropathic changes. We describe the outcome of seven elbow replacements in five consecutive patients with severe haemophilia A (native factor levels <
1%) at a mean of 42 months (25 to 65) after operation. All the patients had excellent relief of pain and improvement in function. One failure was due to infection in an immunocompromised patient with both HIV and Hepatitis C antibodies who was on anti-retroviral chemotherapy. The implant was revised at 30 months in a one-stage procedure and showed no
We operated on 16 patients for ulnar neuropathy associated with osteoarthritis of the elbow. They were all male manual workers, with an average age of 51 years at the time of surgery. The severity of the symptoms was McGowan grade 1 in five patients, grade 2 in nine and grade 3 in two. The mean follow-up was 36 months. The operation consists of resecting the osteophytes around the postcondylar groove. The shallow and narrow cubital tunnel is made deep and wide and the ulnar nerve is replaced with its surrounding soft tissues in the enlarged groove. All patients were relieved of discomfort and all showed some improvement or full recovery of motor and sensory function. The ulnar nerve showed no