Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1301 - 1308
1 Jul 2021
Sugiura K Morimoto M Higashino K Takeuchi M Manabe A Takao S Maeda T Sairyo K

Aims

Although lumbosacral transitional vertebrae (LSTV) are well-documented, few large-scale studies have investigated thoracolumbar transitional vertebrae (TLTV) and spinal numerical variants. This study sought to establish the prevalence of numerical variants and to evaluate their relationship with clinical problems.

Methods

A total of 1,179 patients who had undergone thoracic, abdominal, and pelvic CT scanning were divided into groups according to the number of thoracic and lumbar vertebrae, and the presence or absence of TLTV or LSTV. The prevalence of spinal anomalies was noted. The relationship of spinal anomalies to clinical symptoms (low back pain, Japanese Orthopaedic Association score, Roland-Morris Disability Questionnaire) and degenerative spondylolisthesis (DS) was also investigated.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location.

Cite this article: Bone Joint J 2015; 97-B:1111–17.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1546 - 1550
1 Nov 2012
Longo UG Loppini M Romeo G Maffulli N Denaro V

Wrong-level surgery is a unique pitfall in spinal surgery and is part of the wider field of wrong-site surgery. Wrong-site surgery affects both patients and surgeons and has received much media attention. We performed this systematic review to determine the incidence and prevalence of wrong-level procedures in spinal surgery and to identify effective prevention strategies. We retrieved 12 studies reporting the incidence or prevalence of wrong-site surgery and that provided information about prevention strategies. Of these, ten studies were performed on patients undergoing lumbar spine surgery and two on patients undergoing lumbar, thoracic or cervical spine procedures. A higher frequency of wrong-level surgery in lumbar procedures than in cervical procedures was found. Only one study assessed preventative strategies for wrong-site surgery, demonstrating that current site-verification protocols did not prevent about one-third of the cases. The current literature does not provide a definitive estimate of the occurrence of wrong-site spinal surgery, and there is no published evidence to support the effectiveness of site-verification protocols. Further prevention strategies need to be developed to reduce the risk of wrong-site surgery.