We performed a systematic review and meta-analysis
to compare the efficacy of intermittent mechanical compression combined
with pharmacological thromboprophylaxis, against either mechanical
compression or pharmacological prophylaxis in preventing deep-vein
thrombosis (DVT) and pulmonary embolism in patients undergoing hip
or knee replacement. A total of six randomised controlled trials,
evaluating a total of 1399 patients, were identified. In knee arthroplasty,
the rate of DVT was reduced from 18.7% with anticoagulation alone
to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03;
number needed to treat: seven). There was moderate, albeit non-significant,
heterogeneity (I2 = 42%). In hip replacement, there was
a non-significant reduction in DVT from 8.7% with mechanical compression
alone to 7.2% with additional pharmacological prophylaxis (RR 0.84)
and a significant reduction in DVT from 9.7% with anticoagulation
alone to 0.9% with additional mechanical compression (RR 0.17, p
<
0.001; number needed to treat: 12), with no heterogeneity (I2 =
0%). The included studies had insufficient power to demonstrate
an effect on pulmonary embolism. We conclude that the addition of intermittent mechanical leg
compression augments the efficacy of anticoagulation in preventing
DVT in patients undergoing both knee and hip replacement. Further
research on the role of combined modalities in thromboprophylaxis
in joint replacement and in other high-risk situations, such as fracture
of the hip, is warranted.
This study was undertaken to evaluate the safety and efficacy of retrievable inferior vena cava filters in high-risk orthopaedic patients. A total of 58 patients had a retrievable inferior vena cava filter placed as an adjunct to chemical and mechanical prophylaxis, most commonly for a history of previous
Clinical, haematological or economic benefits of post-operative blood salvage with autologous blood re-transfusion have yet to be clearly demonstrated for primary total hip replacement. We performed a prospective randomised study to analyse differences in postoperative haemoglobin levels and homologous blood requirements in two groups of patients undergoing primary total hip replacement. A series of 158 patients was studied. In one group two vacuum drains were used and in the other the ABTrans autologous retransfusion system. A total of 58 patients (76%) in the re-transfusion group received autologous blood. There was no significant difference in the mean post-operative haemoglobin levels in the two groups. There were, however, significantly fewer patients with post-operative haemoglobin values less than 9.0 g/dl and significantly fewer patients who required transfusion of homologous blood in the re-transfusion group. There was also a small overall cost saving in this group.
Over a two-year period, 265 Norwegian orthopaedic surgeons working at 71 institutions performed 63 484 operations under a tourniquet. Their replies to a questionnaire revealed that they mostly followed modern guidelines in their use of the tourniquet. Most felt that the tourniquet could be left on for two hours, and that it could be re-applied after 15 minutes. A total of 26 complications (one in 2442 operations) that might have been due to the tourniquet were reported, of which 15 were neurological. Three were in the upper limb (one in 6155 operations) and 12 in the lower limb (one in 3752 operations). Two were permanent (one in 31742 operations), but the remainder resolved within six months. One permanent and one transient complication occurred after tourniquet times of three hours. The incidence of tourniquet complications is still at least as high as that estimated in the 1970s.
Using a computer-based quality assurance program, we analysed peri-operative data on 160 patients undergoing one-stage bilateral hip or knee arthroplasties under regional anaesthesia with routine anaesthetic monitoring and only using peripheral intravenous access for peri-operative safety. We monitored defined intra-operative adverse events such as hypotension, myocardial ischaemia, arrhythmias, hypovolaemia, hypertension and early post-operative complications. We also determined post-operative hip and knee function, and patient satisfaction with different aspects of the anaesthetic management. Those patients undergoing one-stage bilateral arthroplasties were matched according to a cross-stratification which used three variables (American Society of Anesthesiologists’ physical status scoring system, age and joint replaced) to patients undergoing unilateral hip or knee arthroplasties. Serious intra-operative adverse events were, with the exception of intra-operative hypotension, very infrequent in patients undergoing bilateral (nine adverse events) as well as unilateral arthroplasties (five adverse events). Early post-operative complications were also infrequent in both groups. However, the risks of receiving a heterologous blood transfusion (odds ratio 2.5; 95% confidence interval (CI) 1.3 to 5.0, estimated by exact conditional logistic regression) or vasoactive drugs (odds ratio 3.9; 95% CI 2.0 to 7.8) were significantly greater for patients undergoing bilateral operations. Patient satisfaction with anaesthesia was high; all patients who underwent the one-stage bilateral operation would choose the same anaesthetic technique again.