The aim of this study was to determine the prevalence of depressive and anxiety disorders prior to total hip (THA) and total knee arthroplasty (TKA) and to assess their impact on the rates of any infection, revision, or reoperation. Between January 2000 and March 2019, 21,469 primary and revision arthroplasties (10,011 THAs; 11,458 TKAs), which were undertaken in 15,504 patients at a single academic medical centre, were identified from a 27-county linked electronic medical record (EMR) system. Depressive and anxiety disorders were identified by diagnoses in the EMR or by using a natural language processing program with subsequent validation from review of the medical records. Patients with mental health diagnoses other than anxiety or depression were excluded.Aims
Methods
Data of high quality are critical for the meaningful interpretation of registry information. The National Joint Registry (NJR) was established in 2002 as the result of an unexpectedly high failure rate of a cemented total hip arthroplasty. The NJR began data collection in 2003. In this study we report on the outcomes following the establishment of a formal data quality (DQ) audit process within the NJR, within which each patient episode entry is validated against the hospital unit’s Patient Administration System and vice-versa. This process enables bidirectional validation of every NJR entry and retrospective correction of any errors in the dataset. In 2014/15 baseline average compliance was 92.6% and this increased year-on-year with repeated audit cycles to 96.0% in 2018/19, with 76.4% of units achieving > 95% compliance. Following the closure of the audit cycle, an overall compliance rate of 97.9% was achieved for the 2018/19 period. An automated system was initiated in 2018 to reduce administrative burden and to integrate the DQ process into standard workflows. Our processes and quality improvement results demonstrate that DQ may be implemented successfully at national level, while minimizing the burden on hospitals. Cite this article:
Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT. TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.Aims
Methods
Although readmission has historically been of primary interest, emergency department (ED) visits are increasingly a point of focus and can serve as a potentially unnecessary gateway to readmission. This study aims to analyze the difference between primary and revision total joint arthroplasty (TJA) cases in terms of the rate and reasons associated with 90-day ED visits. We retrospectively reviewed all patients who underwent TJA from 2011 to 2021 at a single, large, tertiary urban institution. Patients were separated into two cohorts based on whether they underwent primary or revision TJA (rTJA). Outcomes of interest included ED visit within 90-days of surgery, as well as reasons for ED visit and readmission rate. Multivariable logistic regressions were performed to compare the two groups while accounting for all statistically significant demographic variables.Aims
Methods
The aim of this study is to assess the impact of a pilot enhanced recovery after surgery (ERAS) programme on length of stay (LOS) and post-discharge resource usage via service evaluation and cost analysis. Between May and December 2019, 100 patients requiring hip or knee arthroplasty were enrolled with the intention that each would have a preadmission discharge plan, a preoperative education class with nominated helper, a day of surgery admission and mobilization, a day one discharge, and access to a 24/7 dedicated helpline. Each was matched with a patient under the pre-existing pathway from the previous year.Aims
Methods
Day-case arthroplasty is gaining popularity in Europe. We report outcomes from the first 12 months following implementation of a day-case pathway for unicompartmental knee arthroplasty (UKA) and total hip arthroplasty (THA) in an NHS hospital. A total of 47 total hip arthroplasty (THA) and 24 unicompartmental knee arthroplasty (UKA) patients were selected for the day-case arthroplasty pathway, based on preoperative fitness and agreement to participate. Data were likewise collected for a matched control group (n = 58) who followed the standard pathway three months prior to the implementation of the day-case pathway. We report same-day discharge (SDD) success, reasons for delayed discharge, and patient-reported outcomes. Overall length of stay (LOS) for all lower limb arthroplasty was recorded to determine the wider impact of implementing a day-case pathway.Aims
Methods
Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm. We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model.Aims
Methods
Aims. Surgical costs are a major component of healthcare expenditures in the USA. Intraoperative
Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed.Aims
Methods
α-defensin is a biomarker which has been described as having
a high degree of accuracy in the diagnosis of periprosthetic joint
infection (PJI). Current meta-analyses are based on the α-defensin
laboratory-based immunoassay rather than the quick on-table lateral
flow test kit. This study is the first meta-analysis to compare the
accuracy of the α-defensin laboratory-based immunoassay and the
lateral flow test kit for the diagnosis of PJI. A systematic review was performed according to the Preferred
Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
Inclusion criteria were all clinical studies where the diagnosis
of PJI was uncertain. All studies selected used the Musculoskeletal
Infection Society (MSIS) or modified MSIS criteria. Two independent
reviewers reviewed the studies and extracted data. A meta-analysis
of results was carried out: pooled sensitivity, specificity, positive
and negative likelihood ratio, heterogeneity and areas under curves
are reported.Aims
Materials and Methods
The purpose of this study is to determine if higher volume hospitals
have lower costs in revision hip and knee arthroplasty. We questioned the Centres for Medicare and Medicaid Services
(CMS) Inpatient Charge Data and identified 789 hospitals performing
a total of 29 580 revision arthroplasties in 2014. Centres were
dichotomised into high-volume (performing over 50 revision cases
per year) and low-volume. Mean total hospital-specific charges and
inpatient payments were obtained from the database and stratified
based on Diagnosis Related Group (DRG) codes. Patient satisfaction
scores were obtained from the multiyear CMS Hospital Compare database.Aims
Materials and Methods
The aim of this study was to present data on 11 459 patients
who underwent total hip (THA), total knee (TKA) or unicompartmental
knee arthroplasty (UKA) between November 2002 and April 2014 with
aspirin as the primary agent for pharmacological thromboprophylaxis. We analysed the incidence of deep vein thrombosis (DVT) and pulmonary
embolism (PE) then compared the 90-day all-cause mortality with
the corresponding data in the National Joint Registry for England
and Wales (NJR). Aims
Patients and Methods
The Unified Classification System (UCS) was introduced
because of a growing need to have a standardised universal classification
system of periprosthetic fractures. It combines and simplifies many
existing classification systems, and can be applied to any fracture
around any partial or total joint replacement occurring during or
after operation. Our goal was to assess the inter- and intra-observer
reliability of the UCS in association with knee replacement when
classifying fractures affecting one or more of the femur, tibia
or patella. We used an international panel of ten orthopaedic surgeons with
subspecialty fellowship training and expertise in adult hip and
knee reconstruction (‘experts’) and ten residents of orthopaedic
surgery in the last two years of training (‘pre-experts’). They
each received 15 radiographs for evaluation. After six weeks they
evaluated the same radiographs again but in a different order. The reliability was assessed using the Kappa and weighted Kappa
values. The Kappa values for inter-observer reliability for the experts
and the pre-experts were 0.741 (95% confidence interval (CI) 0.707
to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted
Kappa values for intra-observer reliability for the experts and
pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI
0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near
perfect’ intra-observer reliability when used for periprosthetic
fractures in association with knee replacement in the hands of experienced
and inexperienced users. Cite this article:
Obtaining a balanced flexion gap with correct
femoral component rotation is one of the prerequisites for a successful
outcome after total knee replacement (TKR). Different techniques
for achieving this have been described. In this study we prospectively
compared gap-balancing Both groups systematically reproduced a similar external rotation
of the femoral component relative to the surgical transepicondylar
axis: 2.4°
Using general practitioner records and hospital
notes and through direct telephone conversation with patients, we investigated
the accuracy of nine patient-reported complications gathered from
a self-completed questionnaire after elective joint replacement
surgery of the hip and knee. A total of 402 post-discharge complications
were reported after 8546 elective operations that were undertaken
within a three-year period. These were reported by 136 men and 240
women with a mean age of 71.8 years (34 to 93). A total of 319 reported
complications (79.4%; 95% confidence interval 75.4 to 83.3) were
confirmed to be correct. High rates of correct reporting were demonstrated
for infection (94.5%) and the need for further surgery (100%), whereas
the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism,
myocardial infarction and stroke were lower (75% to 84.2%). Dislocation,
peri-prosthetic fractures and nerve palsy had modest rates of correct
reporting (36% to 57.1%). More patients who had knee surgery delivered
incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations, it appears that post-operative complications
may form part of a larger patient-reported outcome programme after
elective joint replacement surgery.
We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value. Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p <
0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.
We have developed a novel method of calculating the radiological magnification of the hip using two separate radio-opaque markers. We recruited 74 patients undergoing radiological assessment following total hip replacement. Both the new double marker and a conventional single marker were used by the radiographer at the time of x-ray. The predicted magnification according to each marker was calculated, as was the true radiological magnification of the components. The correlation between true and predicted magnification was good using the double marker (r = 0.90, n = 74, p <
0.001), but only moderate for the single marker (r = 0.50, n = 63, p <
0.001). The median error was significantly less for the double marker than for the single (1.1% The double marker method appears to be superior to the single marker method when used in the clinical environment.
As part of the government’s initiative to reduce waiting times for major joint surgery in Wales, the Cardiff and Vale NHS Trust sent 224 patients (258 knees) to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement. The Kinemax total knee replacement system was used in all cases. The cumulative survival rate at three years was 79.2% (95% confidence interval (CI) 69.2 to 86.8) using re-operation for any cause as an endpoint and 85.3% (95% CI 75.9 to 91.8) using aseptic revision as an endpoint. This is significantly worse than that recorded in the published literature. These poor results have resulted in a significant impact on our service.
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs.