We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function. All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted.Aims
Methods
This study compares the cost-effectiveness of
treating dorsally displaced distal radial fractures with a volar
locking plate and percutaneous fixation. It was performed from the
perspective of the National Health Service (NHS) using data from
a single-centre randomised controlled trial. In total 130 patients
(18 to 73 years of age) with a dorsally displaced distal radial
fracture were randomised to treatment with either a volar locking
plate (n = 66) or percutaneous fixation (n = 64). The methodology
was according to National Institute for Health and Care Excellence guidance
for technology appraisals. . There were no significant differences in quality of life scores
between groups at any time point in the study. Both groups returned
to baseline one year post-operatively. NHS costs for the plate group were significantly higher (p <
0.001, 95% confidence interval 497 to 930). For an additional £713,
fixation with a volar locking plate offered 0.0178 additional quality-adjusted
life years in the year after surgery. The incremental cost-effectiveness
ratio (ICER) for plate fixation relative to percutaneous fixation
at list price was £40 068. When adjusting the prices of the implants
for a 20% hospital discount, the ICER was £31 898. Patients who
underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from
the perspective of the NHS, of fixation using a volar locking plate
over percutaneous fixation for the operative treatment of a dorsally
displaced radial fracture. Cite this article:
We investigated the response of chronic neck and shoulder pain to decompression of the carpal tunnel in 38 patients with whiplash injury. We also determined the plasma levels of substance P (SP) and calcitonin gene-related peptide (CGRP), which are inflammatory peptides that sensitise nociceptors. Compared with normal control subjects, the mean concentrations of SP (220 v 28 ng/l; p <
0.0001) and CGRP (400 v 85 ng/l; p <
0.0005) were high in patients with chronic shoulder and neck pain before surgery. After operation their levels fell to normal. There was resolution of neurological symptoms with improvement of pain in 90% of patients. Only two of the 30 with chronic neck and shoulder pain who had been treated conservatively showed improvement when followed up at two years. In spite of having neuropathic pain arising from the median nerve, all these patients had normal electromyographic and nerve-conduction studies. Chronic pain in whiplash injury may be caused by ‘atypical’ carpal tunnel syndrome and responds favourably to surgery which is indicated in patients with neck, shoulder and arm pain but not in those with mild symptoms in the hand. Previously, the presence of persistent neurological symptoms has been accepted as a sign of a poor outcome after a whiplash injury, but our study suggests that it may be possible to treat chronic pain by