Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 944 - 952
25 Oct 2024
Deveza L El Amine MA Becker AS Nolan J Hwang S Hameed M Vaynrub M

Aims

Treatment of high-grade limb bone sarcoma that invades a joint requires en bloc extra-articular excision. MRI can demonstrate joint invasion but is frequently inconclusive, and its predictive value is unknown. We evaluated the diagnostic accuracy of direct and indirect radiological signs of intra-articular tumour extension and the performance characteristics of MRI findings of intra-articular tumour extension.

Methods

We performed a retrospective case-control study of patients who underwent extra-articular excision for sarcoma of the knee, hip, or shoulder from 1 June 2000 to 1 November 2020. Radiologists blinded to the pathology results evaluated preoperative MRI for three direct signs of joint invasion (capsular disruption, cortical breach, cartilage invasion) and indirect signs (e.g. joint effusion, synovial thickening). The discriminatory ability of MRI to detect intra-articular tumour extension was determined by receiver operating characteristic analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims

The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach.

Methods

A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 559 - 567
1 May 2023
Aoude A Nikomarov D Perera JR Ibe IK Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims

Giant cell tumour of bone (GCTB) is a locally aggressive lesion that is difficult to treat as salvaging the joint can be associated with a high rate of local recurrence (LR). We evaluated the risk factors for tumour relapse after treatment of a GCTB of the limbs.

Methods

A total of 354 consecutive patients with a GCTB underwent joint salvage by curettage and reconstruction with bone graft and/or cement or en bloc resection. Patient, tumour, and treatment factors were analyzed for their impact on LR. Patients treated with denosumab were excluded.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims

The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition.

Methods

The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs.


Aims

This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for bone tumour resection.

Methods

We retrospectively reviewed 29 bone tumour resections that used 3DP-PSRGs based on 3D CT and 3D MRI. We evaluated the resection amount errors and resection margin errors relative to the preoperative plans. Guide-fitting errors and guide distortion were evaluated intraoperatively and one month postoperatively, respectively. We categorized each of these error types into three grades (grade 1, < 1 mm; grade 2, 1 to 3 mm; and grade 3, > 3 mm) to evaluate the overall accuracy.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1421 - 1427
1 Aug 2021
Li J Lu Y Chen G Li M Xiao X Ji C Wang Z Guo Z

Aims

We have previously reported cryoablation-assisted joint-sparing surgery for osteosarcoma with epiphyseal involvement. However, it is not clear whether this is a comparable alternative to conventional joint arthroplasty in terms of oncological and functional outcomes.

Methods

A total of 22 patients who had localized osteosarcoma with epiphyseal involvement around the knee and underwent limb salvage surgery were allocated to joint preservation (JP) group and joint arthroplasty (JA) group. Subjects were followed with radiographs, Musculoskeletal Tumor Society (MSTS) score, and clinical evaluations at one, three, and five years postoperatively.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 184 - 191
1 Jan 2021
Perrin DL Visgauss JD Wilson DA Griffin AM Abdul Razak AR Ferguson PC Wunder JS

Aims

Local recurrence remains a challenging and common problem following curettage and joint-sparing surgery for giant cell tumour of bone (GCTB). We previously reported a 15% local recurrence rate at a median follow-up of 30 months in 20 patients with high-risk GCTB treated with neoadjuvant Denosumab. The aim of this study was to determine if this initial favourable outcome following the use of Denosumab was maintained with longer follow-up.

Methods

Patients with GCTB of the limb considered high-risk for unsuccessful joint salvage, due to minimal periarticular and subchondral bone, large soft tissue mass, or pathological fracture, were treated with Denosumab followed by extended intralesional curettage with the goal of preserving the joint surface. Patients were followed for local recurrence, metastasis, and secondary sarcoma.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 732 - 738
1 Jun 2019
Liu Q He H Zeng H Yuan Y Long F Tian J Luo W

Aims

The aim of this study was to evaluate the efficacy of the surgical dislocation approach and modified trapdoor procedure for the treatment of chondroblastoma of the femoral head.

Patients and Methods

A total of 17 patients (ten boys, seven girls; mean age 16.4 years (11 to 26)) diagnosed with chondroblastoma of the femoral head who underwent surgical dislocation of the hip joint, modified trapdoor procedure, curettage, and bone grafting were enrolled in this study and were followed-up for a mean of 35.9 months (12 to 76). Healing and any local recurrence were assessed via clinical and radiological tests. Functional outcome was evaluated using the Musculoskeletal Tumour Society scoring system (MSTS). Patterns of bone destruction were evaluated using the Lodwick classification. Secondary osteoarthritis was classified via radiological analysis following the Kellgren–Lawrence grading system. Steinberg classification was used to evaluate osteonecrosis of the femoral head.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 101 - 108
1 Jan 2018
Stevenson JD Kumar VS Cribb GL Cool P

Aims. Dislocation rates are reportedly lower in patients requiring proximal femoral hemiarthroplasty than for patients undergoing hip arthroplasty for neoplasia. Without acetabular replacement, pain due to acetabular wear necessitating revision surgery has been described. We aimed to determine whether wear of the native acetabulum following hemiarthroplasty necessitates revision surgery with secondary replacement of the acetabulum after proximal femoral replacement (PFR) for tumour reconstruction. Patients and Methods. We reviewed 100 consecutive PFRs performed between January 2003 and January 2013 without acetabular resurfacing. The procedure was undertaken in 74 patients with metastases, for a primary bone tumour in 20 and for myeloma in six. There were 48 male and 52 female patients, with a mean age of 61.4 years (19 to 85) and median follow-up of two years (interquartile range (IQR) 0.5 to 3.7 years). In total, 52 patients presented with a pathological fracture and six presented with failed fixation of a previously instrumented pathological fracture. Results. All patients underwent reconstruction with either a unipolar (n = 64) or bipolar (n = 36) articulation. There were no dislocations and no acetabular resurfacings. Articular wear was graded using the criteria of Baker et al from 0 to 3, where by 0 is normal; grade 1 represents a narrowing of articular cartilage and no bone erosion; grade 2 represents acetabular bone erosion and early migration; and grade 3 represents protrusio acetabuli. Of the 49 patients with radiological follow-up greater than one year, six demonstrated grade 1 acetabular wear and two demonstrated grade 2 acetabular wear. The remainder demonstrated no radiographic evidence of wear. Median medial migration was 0.3 mm (IQR -0.2 to 0.7) and superior migration was 0.3 mm (IQR -0.2 to 0.6). No relationship between unipolar versus bipolar articulations and wear was evident. Conclusion. Hemiarthroplasty PFRs for tumour reconstruction eliminate joint instability and, in the short to medium term, do not lead to native acetabular wear necessitating later acetabular resurfacing. Cite this article: Bone Joint J 2018;100B:101–8


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 555 - 561
1 Apr 2014
Igarashi K Yamamoto N Shirai T Hayashi K Nishida H Kimura H Takeuchi A Tsuchiya H

In 1999, we developed a technique for biological reconstruction after excision of a bone tumour, which involved using autografts of the bone containing the tumour treated with liquid nitrogen. We have previously reported the use of this technique in 28 patients at a mean follow up of 27 months (10 to 54).

In this study, we included 72 patients who underwent reconstruction using this technique. A total of 33 patients died and three were lost to follow-up, at a mean of 23 months (2 to 56) post-operatively, leaving 36 patients available for a assessment at a mean of 101 months 16 to 163) post-operatively. The methods of reconstruction included an osteo-articular graft in 16, an intercalary in 13 and, a composite graft with prosthesis in seven.

Post-operative function was excellent in 26 patients (72.2%), good in seven (19.4%), and fair in three (8.3%) according to the functional evaluation system of Enneking. No recurrent tumour occurred within the grafts. The autografts survived in 29 patients (80.6%), and the rates of survival at five and ten years were 86.1% and 80.6 %, respectively. Seven of 16 osteo-articular grafts (44%) failed because of fracture or infection, but all the composite and intercalary grafts survived.

The long-term outcomes of frozen autografting, particularly using composite and intercalary grafts, are satisfactory and thus represent a good method of treatment for patients with a sarcoma of bone or soft tissue.

Cite this article: Bone Joint J 2014;96-B:555–61.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 127 - 131
1 Jan 2014
Wijsbek AE Vazquez-Garcia BL Grimer RJ Carter SR Abudu AA Tillman RM Jeys L

The purpose of this study was to assess whether the use of a joint-sparing technique such as curettage and grafting was successful in eradicating giant cell tumours of the proximal femur, or whether an alternative strategy was more appropriate.

Between 1974 and 2012, 24 patients with a giant cell tumour of the proximal femur were treated primarily at our hospital. Treatment was either joint sparing or joint replacing. Joint-sparing treatment was undertaken in ten patients by curettage with or without adjunctive bone graft. Joint replacement was by total hip replacement in nine patients and endoprosthetic replacement in five. All 11 patients who presented with a pathological fracture were treated by replacement.

Local recurrence occurred in five patients (21%): two were treated by hip replacement, three by curettage and none with an endoprosthesis. Of the ten patients treated initially by curettage, six had a successful outcome without local recurrence and required no further surgery. Three eventually needed a hip replacement for local recurrence and one an endoprosthetic replacement for mechanical failure. Thus 18 patients had the affected joint replaced and only six (25%) retained their native joint. Overall, 60% of patients without a pathological fracture who were treated with curettage had a successful outcome.

Cite this article: Bone Joint J 2014;96-B:127–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 707 - 712
1 May 2010
Siegel HJ Lopez-Ben R Mann JP Ponce BA

Bone loss secondary to primary or metastatic lesions of the proximal humerus remains a challenging surgical problem. Options include preservation of the joint with stabilisation using internal fixation or resection of the tumour with prosthetic replacement. Resection of the proximal humerus often includes the greater tuberosity and adjacent diaphysis, which may result in poor function secondary to loss of the rotator cuff and/or deltoid function. Preservation of the joint with internal fixation may reduce the time in hospital and peri-operative morbidity compared with joint replacement, and result in a better functional outcome. We included 32 patients with pathological fractures of the proximal humerus in this study. Functional and radiological assessments were performed. At a mean follow-up of 17.6 months (8 to 61) there was no radiological evidence of failure of fixation. The mean revised musculoskeletal Tumour Society functional score was 94.6% (86% to 99%). There was recurrent tumour requiring further surgery in four patients (12.5%). Of the 22 patients who were employed prior to presentation all returned to work without restrictions.

The use of a locking plate combined with augmentation with cement extends the indications for salvage of the proximal humerus with good function in patients with pathological and impending pathological fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 401 - 404
1 Mar 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Jeys LM

We undertook a cemental unipolar proximal femoral endoprosthetic replacement in 131 patients with a mean age of 50 years (2 to 84). Primary malignant tumours were present in 54 patients and 67 had metastatic disease. In addition, eight patients had either lymphoma or myeloma and two had non-oncological disorders. The mean follow-up was 27 months (0 to 180). An acetabular revision was required later in 14 patients, 12 of whom had been under the age of 21 years at the time of insertion of their original prosthesis. The risk of acetabular revision in patients over 21 years of age was 8% at five years compared with 36% in those aged under 21 years. All the unipolar hips in this younger age group required revision within 11 years of the initial operation.

We conclude that unipolar replacement should not be used in younger patients and should be avoided in patients with a life expectancy of more than five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated.

The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221).

The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°).

At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 361 - 365
1 Mar 2007
von Steyern FV Kristiansson I Jonsson K Mannfolk P Heineg̊rd D Rydholm A

We reviewed nine patients at a mean period of 11 years (6 to 16) after curettage and cementing of a giant-cell tumour around the knee to determine if there were any long-term adverse effects on the cartilage. Plain radiography, MRI, delayed gadolinium-enhanced MRI of the cartilage and measurement of the serum level of cartilage oligomeric matrix protein were carried out. The functional outcome was evaluated using the Lysholm knee score.

Each patient was physically active and had returned to their previous occupation. Most participated in recreational sports or exercise.

The mean Lysholm knee score was 92 (83 to 100). Only one patient was found to have cartilage damage adjacent to the cement. This patient had a history of intra-articular fracture and local recurrence, leading to degenerative changes.

Interpretation of the data obtained from delayed gadolinium-enhanced MRI of the cartilage was difficult, with variation in the T1 values which did not correlate with the clinical or radiological findings. We did not find it helpful in the early diagnosis of degeneration of cartilage. We also found no obvious correlation between the serum cartilage oligomeric matrix protein level and the radiological and MR findings, function, time after surgery and the age of the patient.

In summary, we found no evidence that the long-term presence of cement close to the knee joint was associated with the development of degenerative osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 531 - 535
1 Apr 2006
von Steyern FV Bauer HCF Trovik C Kivioja A Bergh P Jörgensen PH Foller̊s G Rydholm A

We retrospectively studied local recurrence of giant cell tumour in long bones following treatment with curettage and cementing in 137 patients. The median follow-up time was 60 months (3 to 166). A total of 19 patients (14%) had at least one local recurrence, the first was diagnosed at a median of 17 months (3 to 29) after treatment of the primary tumour. There were 13 patients with a total of 15 local recurrences who were successfully treated by further curettage and cementing. Two patients with a second local recurrence were consequently treated twice. At the last follow-up, at a median of 53 months (3 to 128) after the most recent operation, all patients were free from disease and had good function.

We concluded that local recurrence of giant cell tumour after curettage and cementing in long bones can generally be successfully treated with further curettage and cementing, with only a minor risk of increased morbidity. This suggests that more extensive surgery for the primary tumour in an attempt to obtain wide margins is not the method of choice, since it leaves the patient with higher morbidity with no significant gain with respect to cure of the disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 974 - 978
1 Jul 2005
Suneja R Grimer RJ Belthur M Jeys L Carter SR Tillman RM Davies AM

We undertook this retrospective study to determine the rate of recurrence and functional outcome after intralesional curettage for chondroblastoma of bone. The factors associated with aggressive behaviour of the tumour were also analysed. We reviewed 53 patients with histologically-proven chondroblastoma who were treated by intralesional curettage in our unit between 1974 and 2000. They were followed up for at least two years to a maximum of 27 years.

Seven (13.2%) had a histologically-proven local recurrence. Three underwent a second intralesional curettage and had no further recurrence. Two had endoprosthetic replacement of the proximal humerus and two underwent below-knee amputation after aggressive local recurrence. One patient had the rare malignant metastatic chondroblastoma and eventually died. The mean Musculoskeletal Tumour Society functional score of the survivors was 94.2%.

We conclude that meticulous intralesional curettage alone can achieve low rates of local recurrence and excellent long-term function.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 218 - 225
1 Feb 2005
Tsuchiya H Wan SL Sakayama K Yamamoto N Nishida H Tomita K

We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or composite use of prosthetic replacement. Bone graft or cement was used to augment bone strength when necessary.

The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1162 - 1166
1 Nov 2002
Tsuchiya H Abdel-Wanis ME Sakurakichi K Yamashiro T Tomita K

In 11 patients juxta-articular osteosarcoma around the knee was treated by intraepiphyseal excision of the tumour and reconstruction of the bone defect by distraction osteogenesis. Preoperative and postoperative chemotherapy was given to eight patients with high-grade tumours. The articular cartilage of the epiphysis and a maximum of healthy soft tissues were preserved. Distraction osteogenesis was then carried out. The mean gain in length was 9.7 cm. Full function of the limb was preserved in all except one patient, with a mean follow-up of 53.8 months. Treatment of juxta-articular osteosarcomas around the knee with joint preservation and biological reconstruction using distraction osteogenesis can give excellent functional results


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1156 - 1161
1 Nov 2002
Chen WM Chen TH Huang CK Chiang CC Lo WH

Autogenous bone graft which has been either autoclaved or irradiated is commonly used in oriental countries as an alternative to allograft. We started to use the technique of extracorporeal irradiation of the resected specimen and reimplantation (ECIR) in 1991. There was, however, a high incidence of fracture of the irradiated bone and loss of articular cartilage. In an attempt to reduce these complications, we combined the irradiated autograft with a conventional arthroplasty. Between 1995 and 1998, 14 patients underwent limb salvage by this method. Seven had an osteosarcoma, two bony metastases, three a chondrosarcoma, one a malignant fibrous histiocytoma, and one a leiomyosarcoma. Ten tumours were located in the proximal femur, two in the proximal humerus, and two in the distal femur. One patient who had a solitary metastasis in the proximal part of the left femur died from lung metastases 13 months after operation. The remaining 13 patients were alive and without evidence of local recurrence or distant metastases at a mean follow-up of 43 months (28 to 72). Postoperative palsy of the sciatic nerve occurred in one patient, but no complications such as wound infection, fracture, or nonunion were seen. All host-irradiated bone junctions healed uneventfully within eight months. Using the Enneking functional evaluation system, the mean postoperative score for all 14 patients was 80% (57 to 93). The use of irradiated autograft prosthesis composites reduces the complications of ECIR and gives good functional results. It may be a good alternative in limb-salvage surgery, especially in countries where it is difficult to obtain allografts