Advertisement for orthosearch.org.uk
Results 1 - 20 of 29
Results per page:
Bone & Joint Research
Vol. 13, Issue 10 | Pages 588 - 595
17 Oct 2024
Breu R Avelar C Bertalan Z Grillari J Redl H Ljuhar R Quadlbauer S Hausner T

Aims. The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support. Methods. The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared. Results. At the time of the study, the CNN model showed an area under the receiver operating curve of 0.97. AI assistance improved the physician’s sensitivity (correct fracture detection) from 80% to 87%, and the specificity (correct fracture exclusion) from 91% to 95%. The overall error rate (combined false positive and false negative) was reduced from 14% without AI to 9% with AI. Conclusion. The use of a CNN model as a second opinion can improve the diagnostic accuracy of DRF detection in the study setting. Cite this article: Bone Joint Res 2024;13(10):588–595


Bone & Joint Research
Vol. 12, Issue 3 | Pages 165 - 177
1 Mar 2023
Boyer P Burns D Whyne C

Aims. An objective technological solution for tracking adherence to at-home shoulder physiotherapy is important for improving patient engagement and rehabilitation outcomes, but remains a significant challenge. The aim of this research was to evaluate performance of machine-learning (ML) methodologies for detecting and classifying inertial data collected during in-clinic and at-home shoulder physiotherapy exercise. Methods. A smartwatch was used to collect inertial data from 42 patients performing shoulder physiotherapy exercises for rotator cuff injuries in both in-clinic and at-home settings. A two-stage ML approach was used to detect out-of-distribution (OOD) data (to remove non-exercise data) and subsequently for classification of exercises. We evaluated the performance impact of grouping exercises by motion type, inclusion of non-exercise data for algorithm training, and a patient-specific approach to exercise classification. Algorithm performance was evaluated using both in-clinic and at-home data. Results. The patient-specific approach with engineered features achieved the highest in-clinic performance for differentiating physiotherapy exercise from non-exercise activity (area under the receiver operating characteristic (AUROC) = 0.924). Including non-exercise data in algorithm training further improved classifier performance (random forest, AUROC = 0.985). The highest accuracy achieved for classifying individual in-clinic exercises was 0.903, using a patient-specific method with deep neural network model extracted features. Grouping exercises by motion type improved exercise classification. For at-home data, OOD detection yielded similar performance with the non-exercise data in the algorithm training (fully convolutional network AUROC = 0.919). Conclusion. Including non-exercise data in algorithm training improves detection of exercises. A patient-specific approach leveraging data from earlier patient-supervised sessions should be considered but is highly dependent on per-patient data quality. Cite this article: Bone Joint Res 2023;12(3):165–177


Bone & Joint Research
Vol. 12, Issue 2 | Pages 103 - 112
1 Feb 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau E Rupp M

Aims

The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate?

Methods

PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments.


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims

To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound.

Methods

Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 952 - 959
1 Jul 2013
Cai X Yan S Giddins G

Most patients with a nightstick fracture of the ulna are treated conservatively. Various techniques of immobilisation or early mobilisation have been studied. We performed a systematic review of all published randomised controlled trials and observational studies that have assessed the outcome of these fractures following above- or below-elbow immobilisation, bracing and early mobilisation. We searched multiple electronic databases, related bibliographies and other studies. We included 27 studies comprising 1629 fractures in the final analysis. The data relating to the time to radiological union and the rates of delayed union and nonunion could be pooled and analysed statistically.

We found that early mobilisation produced the shortest radiological time to union (mean 8.0 weeks) and the lowest mean rate of nonunion (0.6%). Fractures treated with above- or below-elbow immobilisation and braces had longer mean radiological times to union (9.2 weeks, 9.2 weeks and 8.7 weeks, respectively) and higher mean rates of nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically significant difference in the rate of non- or delayed union between those treated by early mobilisation and the three forms of immobilisation (p = 0.142 to p = 1.000, respectively). All the studies had significant biases, but until a robust randomised controlled trial is undertaken the best advice for the treatment of undisplaced or partially displaced nightstick fractures appears to be early mobilisation, with a removable forearm support for comfort as required.

Cite this article: Bone Joint J 2013;95-B:952–9.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA).

A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere.

Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Cite this article: Bone Joint J 2013;95-B:530–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


Bone & Joint Research
Vol. 1, Issue 5 | Pages 78 - 85
1 May 2012
Entezari V Della Croce U DeAngelis JP Ramappa AJ Nazarian A Trechsel BL Dow WA Stanton SK Rosso C Müller A McKenzie B Vartanians V Cereatti A

Objectives. Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras. Methods. In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector. Results. The testing system demonstrated high precision and accuracy based on the expected versus observed displacements of individual axes. The maximum coefficient of variation for displacement of unloaded axes was less than 0.5% for all axes. The expected and observed actual displacements had a high level of correlation with coefficients of determination of 1.0 for all axes. Conclusions. Given that this system can accurately simulate and track simple and complex motion, there is a new opportunity to study kinematics of the shoulder under normal and pathological conditions in a cadaveric shoulder model


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 364 - 369
1 Mar 2011
Suzuki O Sunagawa T Yokota K Nakashima Y Shinomiya R Nakanishi K Ochi M

The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been used. In the remaining six patients, however, all fascicles of the ulnar nerve were separated and electrodiagnosis was performed after stimulation with a commercially available electromyographic system. In these procedures, recording electrodes were placed in flexor carpi ulnaris and the first dorsal interosseous. A single fascicle in the flexor carpi ulnaris in which a high amplitude had been recorded was selected as a donor and transferred to the musculocutaneous nerve. In the two patients who had not undergone electrodiagnosis, the recovery of biceps proved insufficient for normal use. Conversely, in the six patients in whom quantitative electrodiagnosis was used, elbow flexion recovered to an M4 level.

Quantitative intra-operative electrodiagnosis is an effective method of selecting a favourable donor fascicle during the Oberlin procedure. Moreover, fascicles showing a high-amplitude in reading flexor carpi ulnaris are donor nerves that can restore normal elbow flexion without intrinsic loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 540 - 544
1 Apr 2010
Dickson JK Biant LC

Restoration of hand function is rarely achieved after a complete closed traction lesion of the supraclavicular brachial plexus. We describe the injury, treatment, rehabilitation and long-term results of two patients who regained good function of the upper limb and useful function in the hand after such an injury. Successful repairs were performed within six days of injury. Tinel’s sign proved accurate in predicting the ruptures and the distribution of pain was accurate in predicting avulsion. The severe pain that began on the day of injury resolved with the onset of muscle function.

Recovery of muscle function preceded recovery of sensation. Recovery of the function of C and Aδ fibres was the slowest of all.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 235 - 241
1 Feb 2010
van der Lugt JCT Valstar ER Witvoet-Braam SW Nelissen RGHH

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs.

All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (sd 1.0) and in the non-revised 0.7 mm (sd 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1478 - 1481
1 Nov 2009
Lee YH Kim JY Chung MS Baek GH Gong HS Lee SK

We treated 32 displaced mallet finger fractures by a two extension block Kirschner-wire technique. The clinical and radiological outcomes were evaluated at a mean follow-up of 49 months (25 to 84). The mean joint surface involvement was 38.4% (33% to 50%) and 18 patients (56%) had accompanying joint subluxation.

All 32 fractures united with a mean time to union of 6.2 weeks (5.1 to 8.2). Congruent joint surfaces and anatomical reduction were seen in all cases. The mean flexion of the distal interphalangeal joints was 83.1° (75° to 90°) and the mean extension loss was 0.9° (0° to 7°). No digit had a prominent dorsal bump or a recurrent mallet deformity.

We believe that this technique, when properly applied, produces satisfactory results both clinically and radiologically.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1341 - 1346
1 Oct 2009
Rosenblatt Y Young C MacDermid JC King GJW

Between 1995 and 2006, five intra-articular osteotomies of the head of the radius were performed in patients with symptomatic healed displaced articular fractures. Pre-operatively, all patients complained of persistent painful clicking on movement. Only patients with mild or no degenerative changes of the radial head and capitellum were considered for osteotomy. The operations were performed at a mean of 8.2 months (4 to 13) after injury and the patients were reviewed at a mean of 5.5 years (15 months to 12 years) after the osteotomy.

The average Mayo Elbow Performance Index Score improved significantly from 74 before to 88 after operation, with four patients rated as good or excellent (p < 0.05). The subjective patient satisfaction score was 8.4 on a ten-point scale. All osteotomies healed and there were no complications.

In this small series intra-articular osteotomy of the head of the radius was a safe and effective treatment for symptomatic intra-articular malunion without advanced degenerative changes.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1049 - 1053
1 Aug 2009
Braunstein V Kirchhoff C Ockert B Sprecher CM Korner M Mutschler W Wiedemann E Biberthaler P

In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 367 - 373
1 Mar 2009
Allom R Colegate-Stone T Gee M Ismail M Sinha J

A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand score, the Oxford shoulder score and the Constant-Murley score, which was used as a reference. All scores were standardised to a scale of 0 to 100 for comparison. Statistical analysis compared the post-operative course and the mean score for the subjective Disabilities to the Arm, Shoulder and Hand score and Oxford shoulder score, with the objective Constant score at each interval. A strong correlation was evident between both subjective scores and the Constant score. We concluded that both the subjective scores would be useful substitutes for the Constant score, obviating the need for a trained investigator and the specialist equipment required to perform the Constant score.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1341 - 1347
1 Oct 2008
Levy O Venkateswaran B Even T Ravenscroft M Copeland S

We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans.

Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six massive (> 5 cm in diameter) tears. There was a statistically significant increase in the size of the tear with increasing age (p = 0.0048).

The mean pre-operative Constant score was 41.4 points (95% confidence interval, 37.9 to 44.9), which improved to 84.5 (95% confidence interval, 82.2 to 86.9). A significant inverse association (p = 0.0074), was observed between the size of the tear and the post-operative Constant score, with patients having smaller tears attaining higher Constant scores after repair. Post-operatively, 80 patients (78.4%) were able to resume their occupations and 84 (82.4%) returned to their pre-injury leisure activities. Only eight (7.8%) of 102 patients were not satisfied with the outcome.

Recurrent tears were detected by ultrasound in 19 (18.6%) patients, and were generally smaller than the original ones. Patients with recurrent tears experienced a mean improvement of 31.6 points (95% confidence interval, 23.6 to 39.6) in their post-operative Constant scores. Those with intact repairs had significantly improved (p < 0.0001) Constant scores (mean improvement 46.3 points, 95% confidence interval, 41.9 to 50.6). Patient satisfaction was high in 94 cases (92%), irrespective of the outcome of the Constant score. Recurrent tears appear to be linked to age-related degeneration.

Arthroscopic repair of the rotator cuff leads to high rates of satisfaction (92%) and good functional results, albeit with a recurrence rate of 18.6% (19 of 102).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows.

Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically.

A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful.

Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations.