Advertisement for orthosearch.org.uk
Results 1 - 24 of 24
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 294 - 300
1 Mar 2023
Sangaletti R Zanna L Akkaya M Sandiford N Ekhtiari S Gehrke T Citak M

Aims

Despite numerous studies focusing on periprosthetic joint infections (PJIs), there are no robust data on the risk factors and timing of metachronous infections. Metachronous PJIs are PJIs that can arise in the same or other artificial joints after a period of time, in patients who have previously had PJI.

Methods

Between January 2010 and December 2018, 661 patients with multiple joint prostheses in situ were treated for PJI at our institution. Of these, 73 patients (11%) developed a metachronous PJI (periprosthetic infection in patients who have previously had PJI in another joint, after a lag period) after a mean time interval of 49.5 months (SD 30.24; 7 to 82.9). To identify patient-related risk factors for a metachronous PJI, the following parameters were analyzed: sex; age; BMI; and pre-existing comorbidity. Metachronous infections were divided into three groups: Group 1, metachronous infections in ipsilateral joints; Group 2, metachronous infections of the contralateral lower limb; and Group 3, metachronous infections of the lower and upper limb.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal. Results. The mean MEPS significantly improved from 47 (15 to 70) points preoperatively to 95 (70 to 100) points at final follow-up (p < 0.001). Complications were noted in six elbows (23%) in six patients, and of these, four with an ulnar neuropathy and one elbow with postoperative traumatic fracture required additional surgeries. There was no revision with implant removal, and there was no radiological evidence of loosening around the components. With any revision surgery as the endpoint, the survival rates up to 25 years were 78.1% (95% confidence interval 52.8 to 90.6) as determined by Kaplan-Meier analysis. Conclusion. The clinical outcome of primary unlinked TEA for young patients with RA was satisfactory and comparable with that for elderly patients. A favourable survival rate without implant removal might support the use of unlinked devices for young patients with this disease entity, with a caution of a relatively high complication rate regarding ulnar neuropathy. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Jt Open 2023;4(1):19–26


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims

The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome.

Methods

We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims. We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA). Materials and Methods. We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203). Results. Aseptic loosening of the ulnar component occurred in 11 elbows. There was no radiolucency around any humeral component. There was one deep infection. The survival rate according to Kaplan-Meier survivorship analysis was 87.8% after five years and 70.7% after ten years. The range of extension/flexion was a mean -38° (-80° to 0°)/105° (30° to 150°) before surgery and -40° (-70° to -20°)/132° (100° to 150°) at the final follow-up, while the mean Mayo elbow performance score was 43 before surgery and 80 at final follow-up. Disease duration of RA up to the TEA of < 15 years and a pre-operative range of movement (ROM) of > 85° were significant risk factors for revision or aseptic loosening. Conclusion. Although Kudo type-5 prostheses gave satisfactory results in the short-term, aseptic loosening increased after five years. In most cases, elbow function was maintained in the long-term without loosening of the implant. A short duration from the onset of RA to TEA and a large pre-operative ROM were significant risk factors for revision or aseptic loosening. Cite this article: Bone Joint J 2017;99-B:818–23


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 66 - 72
1 Jan 2017
Sigmund IK Holinka J Gamper J Staats K Böhler C Kubista B Windhager R

Aims

The diagnosis of periprosthetic joint infection (PJI) remains demanding due to limitations of all the available diagnostic tests. The synovial fluid marker, α-defensin, is a promising adjunct for the assessment of potential PJI. The purpose of this study was to investigate the qualitative assessment of α-defensin, using Synovasure to detect or exclude periprosthetic infection in total joint arthroplasty.

Patients and Methods

We studied 50 patients (28 women, 22 men, mean age 65 years; 20 to 89) with a clinical indication for revision arthroplasty who met the inclusion criteria of this prospective diagnostic study. The presence of α-defensin was determined using the qualitative Synovasure test and compared with standard diagnostic methods for PJI. Based on modified Musculoskeletal Infection Society (MSIS) criteria, 13 cases were categorised as septic and 36 as aseptic revisions. One test was inconclusive.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1539 - 1545
1 Nov 2015
Lenoir H Chammas M Micallef JP Lazerges C Waitzenegger T Coulet B

Determining and accurately restoring the flexion-extension axis of the elbow is essential for functional recovery after total elbow arthroplasty (TEA). We evaluated the effect of morphological features of the elbow on variations of alignment of the components at TEA. Morphological and positioning variables were compared by systematic CT scans of 22 elbows in 21 patients after TEA.

There were five men and 16 women, and the mean age was 63 years (38 to 80). The mean follow-up was 22 months (11 to 44).

The anterior offset and version of the humeral components were significantly affected by the anterior angulation of the humerus (p = 0.052 and p = 0.004, respectively). The anterior offset and version of the ulnar components were strongly significantly affected by the anterior angulation of the ulna (p < 0.001 and p < 0.001).

The closer the anterior angulation of the ulna was to the joint, the lower the ulnar anterior offset (p = 0.030) and version of the ulnar component (p = 0.010). The distance from the joint to the varus angulation also affected the lateral offset of the ulnar component (p = 0.046).

Anatomical variations at the distal humerus and proximal ulna affect the alignment of the components at TEA. This is explained by abutment of the stems of the components and is particularly severe when there are substantial deformities or the deformities are close to the joint.

Cite this article: Bone Joint J 2015;97-B:1539–45.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients.

A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation.

The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients.

Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty.

Cite this article: Bone Joint J 2015;97-B:1377–84.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1382 - 1388
1 Oct 2011
Amirfeyz R Stanley D

We studied, ten patients (11 elbows) who had undergone 14 allograft-prosthesis composite reconstructions following failure of a previous total elbow replacement with massive structural bone loss. There were nine women and one man with a mean age of 64 years (40 to 84), who were reviewed at a mean of 75 months (24 to 213). One patient developed a deep infection after 26 months and had the allograft-prosthesis composite removed, and two patients had mild pain. The median flexion-extension arc was 100° (95% confidence interval (CI) 76° to 124°). With the exception of the patient who had the infected failure, all the patients could use their elbows comfortably without splints or braces for activities of daily living. The mean Mayo Elbow Performance Index improved from 9.5 (95% CI 4.4 to 14.7) pre-operatively to 74 (95% CI 62.4 to 84.9) at final review.

Radiologically, the rate of partial resorption was similar in the humeral and ulnar allografts (three of six and four of eight, respectively; p > 0.999). The patterns of resorption, however, were different. Union at the host-bone-allograft junction was also different between the humeral and ulnar allografts (one of six and seven of eight showing union, respectively; p = 0.03).

At medium-term follow-up, allograft-prosthesis composite reconstruction appears to be a useful salvage technique for failed elbow replacements with massive bone loss. The effects of allograft resorption and host-bone-allograft junctional union on the longevity of allograft-prosthesis composite reconstruction, however, remain unknown, and it is our view that these patients should remain under long-term regular review.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 235 - 241
1 Feb 2010
van der Lugt JCT Valstar ER Witvoet-Braam SW Nelissen RGHH

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs.

All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (sd 1.0) and in the non-revised 0.7 mm (sd 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows.

Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically.

A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful.

Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 78 - 83
1 Jan 2008
Schwab JH Healey JH Athanasian EA

We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide extra-articular en bloc excision. All had a pedicled myocutaneous latissimus dorsi rotation flap for soft-tissue cover and reconstruction of the triceps. Wide negative surgical margins were obtained in all five patients. No local wound complications or infections were seen. There were no local recurrences at a mean follow-up of 60 months (20 to 105). The functional results were excellent in four patients and good in one. Longer term follow-up is necessary to confirm the durability of the elbow reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1225 - 1228
1 Sep 2007
van de Pol GJ Sturm PDJ van Loon CJ Verhagen C Schreurs BW

Allografts of bone from the femoral head are often used in orthopaedic procedures. Although the donated heads are thoroughly tested microscopically before release by the bone bank, some surgeons take additional cultures in the operating theatre before implantation. There is no consensus about the need to take these cultures. We retrospectively assessed the clinical significance of the implantation of positive-cultured bone allografts. The contamination rate at retrieval of the allografts was 6.4% in our bone bank. Intra-operative cultures were taken from 426 femoral head allografts before implantation; 48 (11.3%) had a positive culture. The most frequently encountered micro-organism was coagulase-negative staphylococcus. Deep infection occurred in two of the 48 patients (4.2%). In only one was it likely that the same micro-organism caused the contamination and the subsequent infection.

In our study, the rate of infection in patients receiving positive-cultured allografts at implantation was not higher than the overall rate of infection in allograft surgery suggesting that the positive cultures at implantation probably represent contamination and that the taking of additional cultures is not useful.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up.

We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1460 - 1463
1 Nov 2006
Landor I Vavrik P Jahoda D Guttler K Sosna A

We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instability, one (1.7%) for secondary loosening after fracture, and one elbow (1.7%) was removed because of deep infection. The Kaplan-Meier survival rate was 70% and 53% at ten and 16 years, respectively. Failure of the ulnar component was found to be the main problem in relation to the loosening. Anterior transposition of the ulnar nerve had no influence on ulnar nerve paresthaesiae in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 191 - 195
1 Feb 2005
Mighell MA Dunham RC Rommel EA Frankle MA

We present six patients with chronic dislocation of the elbow who were treated by primary semiconstrained total elbow arthroplasty. All were women with a mean age of 65 years (51 to 76), the mean interval between dislocation and surgery was 17 weeks (5 to 52) and the mean follow-up 58 months (24 to 123).

The most dramatic improvement was in function. The mean American Shoulder and Elbow Surgeon score was 5.2 times better (p < 0.001) and the mean total range of movement increased from 33° to 121° (p < 0.001) after operation. Three patients developed wear of polyethylene. One required revision for a periprosthetic fracture, and another required a bushing exchange.

Primary semiconstrained elbow arthroplasty provides significant, predictable functional improvement. Potential solutions for wear of polyethylene include a different operative technique or design of implant. Despite the high incidence of such wear, total elbow arthroplasty should be considered as a viable treatment option for chronic dislocation of the elbow in elderly patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1129 - 1134
1 Nov 2000
Rozing P

We have reviewed 66 consecutive Souter-Strathclyde arthroplasties of the elbow implanted in 59 patients between 1982 and 1993. Thirteen patients (15 elbows) (19.6%) died. Sixteen elbows (24.2%) were revised, six for aseptic loosening (9%), four (6%) because of fracture or loosening after a fracture, three (4.5%) for infection and three (4.5%) for dislocation. Four patients refused to attend for review. In 33 elbows with a follow-up of 93 months (60 to 167) complete relief of pain was achieved in 22 (67%) when seen at one year. After ten years or more 36% of the elbows were painfree and 64% had occasional slight pain especially under loading or stress. The mean gain in the arc of movement was 16°, but a mean flexion contracture of 33° remained. The main early complications were intraoperative fractures of the epicondyles (9%), postoperative dislocation (4.5%) and ulnar neuropathy. The incidence of ulnar neuropathy before operation was 19%. After operation 20 patients (33%) had an ulnar neuropathy, in seven of which it had been present before operation, and of these weakness of the hypothenar muscle occurred in two. The probability of survival of the Souter-Strathclyde elbow prosthesis based on the Kaplan-Meier calculation is 69% at ten years


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1005 - 1012
1 Nov 1999
Gschwend N Scheier NH Baehler AR

Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed. The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA. There were three cases of aseptic loosening and three of deep infection. The main complication was disassembly of the prosthetic component in nine elbows (13.8%). This last group included two patients with postoperative fractures unrelated to the operative technique and one with neuropathic arthritis. Ulnar neuritis occurred in two patients. Since 87.7% of all the GSB III prostheses implanted in this period remained in situ, our results are comparable with those for hip and knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 394 - 402
1 May 1997
Risung F

The Norway elbow prosthesis is a non-constrained cemented total replacement. It depends on intact collateral ligaments for stability, and allows a full range of movement. The system includes several sizes of components, all freely interchangeable, and semi-constraint can be provided by a locking ring if damaged collateral ligaments make dislocation possible. The prosthesis has been used in more than 350 elbows in Norway and the detailed results for 118 elbows studied prospectively since 1987 are reported. It is inserted through a posterolateral triceps-splitting incision with minimal muscle disruption and bone resection, preserving the collateral ligaments. The results as regards pain relief and range of movement were comparable with those of other elbow prostheses, but there were fewer serious complications. At a mean follow-up of 4.3 years, the failure rate was 3.4%


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 297 - 299
1 Mar 1992
O'Driscoll S An K Korinek S Morrey B

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 248 - 253
1 Mar 1984
Soni R Cavendish M

Eighty elbows in 65 patients with an average age of 57 years have had two-part non-constrained Liverpool elbow arthroplasties performed since 1974. Fifty-five had rheumatoid arthritis, eight osteoarthritis or ankylosis secondary to injury, one osteochondritis dissecans and one pyknodysostosis. The average preoperative range of movement was 42 degrees to 112 degrees with 47 degrees of pronation and 42 degrees of supination. There was significant gain in the arc of movements at follow-up: 32 degrees in the extension-flexion range (average range 32 degrees to 134 degrees of flexion) and 42 degrees in forearm rotation (average pronation 69 degrees and supination 62 degrees). Before operation severe pain was the predominating symptom in 43 elbows (53.8%) but after replacement there was only moderate pain in five elbows (6.2%). The results were excellent in 42 (52.5%), good in 15 (18.7%), fair in 9 (11.3%) and unsatisfactory or poor in 14 (17.5%). Eight elbows required revision of the arthroplasty: three were post-traumatic, disorganised or osteoarthritic joints, three rheumatoid and both elbows in the patient with pyknodysostosis. Loosening of the prosthesis (particularly the humeral component) was the common factor necessitating revision. Of six rheumatoid elbows needing removal of the implant, four had deep infection, one had a dislodged humeral component as a result of injury and in one a divided olecranon had developed non-union. Rheumatoid elbows benefited more than post-traumatic arthritic elbows from the operation. (ABSTRACT TRUNCATED AT 250 WORDS)