Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1021 - 1030
1 Sep 2024
Oto J Herranz R Fuertes M Plana E Verger P Baixauli F Amaya JV Medina P

Aims. Bacterial infection activates neutrophils to release neutrophil extracellular traps (NETs) in bacterial biofilms of periprosthetic joint infections (PJIs). The aim of this study was to evaluate the increase in NET activation and release (NETosis) and haemostasis markers in the plasma of patients with PJI, to evaluate whether such plasma induces the activation of neutrophils, to ascertain whether increased NETosis is also mediated by reduced DNaseI activity, to explore novel therapeutic interventions for NETosis in PJI in vitro, and to evaluate the potential diagnostic use of these markers. Methods. We prospectively recruited 107 patients in the preoperative period of prosthetic surgery, 71 with a suspicion of PJI and 36 who underwent arthroplasty for non-septic indications as controls, and obtained citrated plasma. PJI was confirmed in 50 patients. We measured NET markers, inflammation markers, DNaseI activity, haemostatic markers, and the thrombin generation test (TGT). We analyzed the ability of plasma from confirmed PJI and controls to induce NETosis and to degrade in vitro-generated NETs, and explored the therapeutic restoration of the impairment to degrade NETs of PJI plasma with recombinant human DNaseI. Finally, we assessed the contribution of these markers to the diagnosis of PJI. Results. Patients with confirmed PJI had significantly increased levels of NET markers (cfDNA (p < 0.001), calprotectin (p < 0.001), and neutrophil elastase (p = 0.022)) and inflammation markers (IL-6; p < 0.001) in plasma. Moreover, the plasma of patients with PJI induced significantly more neutrophil activation than the plasma of the controls (p < 0.001) independently of tumour necrosis factor alpha. Patients with PJI also had a reduced DNaseI activity in plasma (p < 0.001), leading to a significantly impaired degradation of NETs (p < 0.001). This could be therapeutically restored with recombinant human DNaseI to the level in the controls. We developed a model to improve the diagnosis of PJI with cfDNA, calprotectin, and the start tail of TGT as predictors, though cfDNA alone achieved a good prediction and is simpler to measure. Conclusion. We confirmed that patients with PJI have an increased level of NETosis in plasma. Their plasma both induced NET release and had an impaired ability to degrade NETs mediated by a reduced DNaseI activity. This can be therapeutically restored in vitro with the approved Dornase alfa, Pulmozyme, which may allow novel methods of treatment. A combination of NETs and haemostatic biomarkers could improve the diagnosis of PJI, especially those patients in whom this diagnosis is uncertain. Cite this article: Bone Joint J 2024;106-B(9):1021–1030


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims. Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods. The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results. Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion. Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively. Cite this article: Bone Joint J 2024;106-B(5 Supple B):118–124


Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims

To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA).

Methods

The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test.


Bone & Joint Research
Vol. 12, Issue 2 | Pages 113 - 120
1 Feb 2023
Cai Y Liang J Chen X Zhang G Jing Z Zhang R Lv L Zhang W Dang X

Aims

This study aimed to explore the diagnostic value of synovial fluid neutrophil extracellular traps (SF-NETs) in periprosthetic joint infection (PJI) diagnosis, and compare it with that of microbial culture, serum ESR and CRP, synovial white blood cell (WBC) count, and polymorphonuclear neutrophil percentage (PMN%).

Methods

In a single health centre, patients with suspected PJI were enrolled from January 2013 to December 2021. The inclusion criteria were: 1) patients who were suspected to have PJI; 2) patients with complete medical records; and 3) patients from whom sufficient synovial fluid was obtained for microbial culture and NET test. Patients who received revision surgeries due to aseptic failure (AF) were selected as controls. Synovial fluid was collected for microbial culture and SF-WBC, SF-PNM%, and SF-NET detection. The receiver operating characteristic curve (ROC) of synovial NET, WBC, PMN%, and area under the curve (AUC) were obtained; the diagnostic efficacies of these diagnostic indexes were calculated and compared.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1193 - 1195
1 Nov 2022
Rajput V Meek RMD Haddad FS

Periprosthetic joint infection (PJI) remains an extremely challenging complication. We have focused on this issue more over the last decade than previously, but there are still many unanswered questions. We now have a workable definition that everyone should align to, but we need to continue to focus on identifying the organisms involved. Surgical strategies are evolving and care is becoming more patient-centred. There are some good studies under way. There are, however, still numerous problems to resolve, and the challenge of PJI remains a major one for the orthopaedic community. This annotation provides some up-to-date thoughts about where we are, and the way forward. There is still scope for plenty of research in this area.

Cite this article: Bone Joint J 2022;104-B(11):1193–1195.


Bone & Joint Research
Vol. 11, Issue 6 | Pages 398 - 408
22 Jun 2022
Xu T Zeng Y Yang X Liu G Lv T Yang H Jiang F Chen Y

Aims

We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan.

Methods

We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims. The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI. Methods. We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified. Results. Overall, 31 studies were identified: 20 described PCR, six described IL6, and five calprotectin. The sensitivity and specificity were 0.78 (95% confidence interval (CI) 0.67 to 0.86) and 0.97 (95% CI 0.94 to 0.99), respectively, for synovial PCR;, 0.86 (95% CI 0.74 to 0.92), and 0.94 (95% CI 0.90 to 0.96), respectively, for synovial IL6; and 0.94 (95% CI 0.82 to 0.98) and 0.93 (95% CI 0.85 to 0.97), respectively, for synovial calprotectin. Likelihood ratio scattergram analyses recommended clinical utility of synovial fluid PCR and IL6 as a confirmatory test only. Synovial calprotectin had utility in the exclusion and confirmation of PJI. Conclusion. Synovial fluid PCR and IL6 had low sensitivity and high specificity in the diagnosis of PJI, and is recommended to be used as confirmatory test. In contrast, synovial fluid calprotectin had both high sensitivity and specificity with utility in both the exclusion and confirmation of PJI. We recommend use of synovial fluid calprotectin studies in the preoperative workup of PJI. Cite this article: Bone Joint J 2022;104-B(3):311–320


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1745 - 1753
1 Dec 2021
Walinga AB Stornebrink T Langerhuizen DWG Struijs PAA Kerkhoffs GMMJ Janssen SJ

Aims

This study aimed to answer two questions: what are the best diagnostic methods for diagnosing bacterial arthritis of a native joint?; and what are the most commonly used definitions for bacterial arthritis of a native joint?

Methods

We performed a search of PubMed, Embase, and Cochrane libraries for relevant studies published between January 1980 and April 2020. Of 3,209 identified studies, we included 27 after full screening. Sensitivity, specificity, area under the curve, and Youden index of diagnostic tests were extracted from included studies. We grouped test characteristics per diagnostic modality. We extracted the definitions used to establish a definitive diagnosis of bacterial arthritis of a native joint per study.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 46 - 55
1 Jan 2021
Grzelecki D Walczak P Szostek M Grajek A Rak S Kowalczewski J

Aims. Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Methods. Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. Results. Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive predictive value, and negative predictive value of 93.3%, 87.5%, 89.4%, and 92.1%, respectively. For synovial fluid with a cut-off value of 1.5 mg/l, these were 95.6%, 95%, 95.5%, and 95%, respectively. Conclusion. This small study suggests that synovial and blood CLP are useful markers in chronic PJI diagnosis with similar or higher sensitivity and specificity than routinely used markers such as CRP, ESR, IL-6, and LE. CLP was not useful to differentiate patients with PJI from those with rheumatoid arthritis. Cite this article: Bone Joint J 2021;103-B(1):46–55


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 18 - 25
1 Jan 2021
McNally M Sousa R Wouthuyzen-Bakker M Chen AF Soriano A Vogely HC Clauss M Higuera CA Trebše R

Aims

The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and interpretation of results. Many new tests have been proposed, but there is no consensus on the place of many of these in the diagnostic pathway. Previous attempts to develop a definition of PJI have not been universally accepted and there remains no reference standard definition.

Methods

This paper reports the outcome of a project developed by the European Bone and Joint Infection Society (EBJIS), and supported by the Musculoskeletal Infection Society (MSIS) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Implant-Associated Infections (ESGIAI). It comprised a comprehensive review of the literature, open discussion with Society members and conference delegates, and an expert panel assessment of the results to produce the final guidance.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 5 - 11
1 Dec 2020
Sharma V Turmezei T Wain J McNamara I


Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims. This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) . Methods. A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy. Results. The median calprotectin level was 776 μg/ml (interquartile range (IQR) 536.5 to 1132) in the PJI group and 54.5 μg/ml (IQR, 38.75 to 78.25) in the aseptic failure (AF) group (p < 0.05). Using a threshold of 173 ug/ml, the sensitivity was 95.2%, with a 97.6% specificity, and the AUC was 0.993. The sensitivity of calprotectin of the antibiotic-treated PJI group was 100% versus 90.9% of the non-antibiotic-treated PJI group. Although 47.6% (ten cases) of the patients in the PJI group received antibiotics before aspiration, the diagnostic efficacy of calprotectin was not affected. The sensitivity and specificity of ESR, CRP, SF-WBCs, and SF-PMNs ranged from 76.2% to 90.5% and 64.3% to 85.7%, respectively. Conclusion. Calprotectin in synovial fluid has great diagnostic efficacy for PJI diagnosisand outperformed ESR, CRP, SF-WBCs, and SF-PMNs. Cite this article: Bone Joint Res 2020;9(8):450–456


Bone & Joint Research
Vol. 9, Issue 5 | Pages 202 - 210
1 May 2020
Trotter AJ Dean R Whitehouse CE Mikalsen J Hill C Brunton-Sim R Kay GL Shakokani M Durst AZE Wain J McNamara I O’Grady J

Aims. This pilot study tested the performance of a rapid assay for diagnosing prosthetic joint infection (PJI), which measures synovial fluid calprotectin from total hip and knee revision patients. Methods. A convenience series of 69 synovial fluid samples from revision patients at the Norfolk and Norwich University Hospital were collected intraoperatively (52 hips, 17 knees) and frozen. Synovial fluid calprotectin was measured retrospectively using a new commercially available lateral flow assay for PJI diagnosis (Lyfstone AS) and compared to International Consensus Meeting (ICM) 2018 criteria and clinical case review (ICM-CR) gold standards. Results. According to ICM, 24 patients were defined as PJI positive and the remaining 45 were negative. The overall accuracy of the lateral flow test compared to ICM was 75.36% (52/69, 95% CI 63.51% to 84.95%), sensitivity and specificity were 75.00% (18/24, 95% CI 53.29% to 90.23%) and 75.56% (34/45, 95% CI 60.46% to 87.12%), respectively, positive predictive value (PPV) was 62.07% (18/29, 95% CI 48.23% to 74.19%) and negative predictive value (NPV) was 85.00% (34/40, 95% CI 73.54% to 92.04%), and area under the receiver operating characteristic (ROC) curve (AUC) was 0.78 (95% CI 0.66 to 0.87). Patient data from discordant cases were reviewed by the clinical team to develop the ICM-CR gold standard. The lateral flow test performance improved significantly when compared to ICM-CR, with accuracy increasing to 82.61% (57/69, 95% CI 71.59% to 90.68%), sensitivity increasing to 94.74% (18/19, 95% CI 73.97% to 99.87%), NPV increasing to 97.50% (39/40, 95% CI 85.20% to 99.62%), and AUC increasing to 0.91 (95% CI 0.81 to 0.96). Test performance was better in knees (100.00% accurate (17/17, 95% CI 80.49% to 100.00%)) compared to hips (76.92% accurate (40/52, 95% CI 63.16% to 87.47%)). Conclusion. This study demonstrates that the calprotectin lateral flow assay could be an effective diagnostic test for PJI, however additional prospective studies testing fresh samples are required. Cite this article:Bone Joint Res. 2020;9(5):202–210


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1345 - 1351
1 Oct 2018
Kuo F Lu Y Wu C You H Lee G Lee MS

Aims

The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI).

Patients and Methods

Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 749 - 754
1 Jun 2018
Partridge DG Winnard C Townsend R Cooper R Stockley I

Aims

The aim of this study was to establish the diagnostic accuracy of culture of joint aspirate with and without saline injection-reaspiration.

Patients and Methods

This is a retrospective analysis of 580 hip and knee aspirations in patients who were deemed to have a moderate to high risk of infection, and who subsequently proceeded to revision arthroplasty over a period of 12 years. It was carried out at a large quaternary referral centre where preoperative aspiration is routine.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 660 - 665
1 May 2017
Wouthuyzen-Bakker M Ploegmakers JJW Kampinga GA Wagenmakers-Huizenga L Jutte PC Muller Kobold AC

Aims . Recently, several synovial biomarkers have been introduced into the algorithm for the diagnosis of a prosthetic joint infection (PJI). Alpha defensin is a promising biomarker, with a high sensitivity and specificity, but it is expensive. Calprotectin is a protein that is present in the cytoplasm of neutrophils, is released upon neutrophil activation and exhibits anti-microbial activity. Our aim, in this study, was to determine the diagnostic potential of synovial calprotectin in the diagnosis of a PJI. Patients and Methods. In this pilot study, we prospectively collected synovial fluid from the hip, knee, shoulder and elbow of 19 patients with a proven PJI and from a control group of 42 patients who underwent revision surgery without a PJI. PJI was diagnosed according to the current diagnostic criteria of the Musculoskeletal Infection Society. Synovial fluid was centrifuged and the supernatant was used to measure the level of calprotectin after applying a lateral flow immunoassay. . Results. The median synovial calprotectin level was 991 mg/L (interquartile range (IQR) 154 to 1787) in those with a PJI and 11 mg/L (IQR 3 to 29) in the control group (p < 0.0001). Using a cut-off value of 50 mg/L, this level showed an excellent diagnostic accuracy, with an area under the curve of 0.94. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was 89%, 90%, 81% and 95% respectively. The NPV was 97% in the nine patients with a chronic PJI. . Conclusion . Synovial calprotectin may be a valuable biomarker in the diagnosis of a PJI, especially in the exclusion of an infection. With a lateral flow immunoassay, a relatively rapid quantitative diagnosis can be made. The measurement is cheap and is easy to use. . Cite this article: Bone Joint J 2017;99-B:660–5