The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Aims
Methods
This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures. A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.Aims
Methods
To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC).Aims
Methods
This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons? A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.Aims
Methods
The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.Aims
Methods
The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow. We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.Aims
Methods
To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.Aims
Methods
Aims. The purpose of this study was to evaluate the relationships between the degree of injury to the medial and lateral collateral ligaments (MCL and LCL) and associated fractures in patients with a posterolateral dislocation of the elbow, using CT and MRI. Methods. We retrospectively reviewed 64 patients who presented between March 2009 and March 2018 with a posterolateral dislocation of the elbow and who underwent CT and MRI. CT revealed fractures of the radial head,
The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (Aims
Patients and Methods
The aim of this study was to report the mid-term clinical outcome
of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties
when used in patients with rheumatoid arthritis (RA). We retrospectively reviewed 87 elbows, in 75 patients with RA,
which was replaced using a cemented JACE total elbow arthroplasty
(TEA) between August 2003 and December 2012, with a follow-up of
96%. There were 72 women and three men, with a mean age of 62 years
(35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition
of each elbow before and after surgery was assessed using the Mayo
Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening
was defined as a progressive radiolucent line of >1 mm that was
completely circumferential around the prosthesis.Aims
Patients and Methods
The aim of this retrospective multicentre study was to evaluate
mid-term results of the operative treatment of Monteggia-like lesions
and to determine the prognostic factors that influence the clinical
and radiological outcome. A total of 46 patients (27 women and 19 men), with a mean age
of 57.7 years (18 to 84) who had sustained a Monteggia-like lesion
were followed up clinically and radiologically after surgical treatment.
The Mayo Modified Wrist Score (MMWS), Mayo Elbow Performance Score
(MEPS), Broberg and Morrey Score, and Disabilities of the Arm, Shoulder
and Hand (DASH) score were used for evaluation at a mean of 65 months
(27 to 111) postoperatively. All ulnar fractures were stabilized
using a proximally contoured or precontoured locking compression
plate. Mason type I fractures of the radial head were treated conservatively, type
II fractures were treated with reconstruction, and type III fractures
with arthroplasty. All Morrey type II and III fractures of the coronoid
process was stabilized using lag screws.Aims
Patients and Methods
Radial head arthroplasty (RHA) may be used in the treatment of
non-reconstructable radial head fractures. The aim of this study
was to evaluate the mid-term clinical and radiographic results of
RHA. Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23
women with either acute injuries (54) or with traumatic sequelae
(23) of a fracture of the radial head. Four designs of RHA were
used, including the Guepar (Small Bone Innovations (SBi)/Stryker;
36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten)
or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up
was 74.0 months (standard deviation (Aims
Patients and Methods
The June 2014 Trauma Roundup360 looks at: BMP use increasing wound complication rates in trauma surgery; can we predict re-admission in trauma?; humeral bundle nailing; how best to treat high-angle femoral neck fractures?; hyperglycaemia and infection; simultaneous soft-tissue and bony repair in terrible triad injuries; metaphyseal malunion in the forearm leading to function restrictions; delayed fixation of the distal radius: not a bad option; and fasciotomies better with shoelaces
We retrospectively assessed the value of identifying
impinging osteophytes using dynamic computer simulation of CT scans
of the elbow in assisting their arthroscopic removal in patients
with osteoarthritis of the elbow. A total of 20 patients were treated
(19 men and one woman, mean age 38 years (19 to 55)) and followed
for a mean of 25 months (24 to 29). We located the impinging osteophytes
dynamically using computerised three-dimensional models of the elbow
based on CT data in three positions of flexion of the elbow. These
were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively
to 9° (0° to 25°) post-operatively, and the mean flexion improved
from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively.
The mean Mayo Elbow Performance Score improved from 62 (30 to 85)
to 95 (70 to 100) post-operatively. All patients had pain in the
elbow pre-operatively which disappeared or decreased post-operatively.
According to their Mayo scores, 14 patients had an excellent clinical
outcome and six a good outcome; 15 were very satisfied and five
were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients
with osteoarthritis of the elbow. Cite this article:
Most patients with a nightstick fracture of the
ulna are treated conservatively. Various techniques of immobilisation or
early mobilisation have been studied. We performed a systematic
review of all published randomised controlled trials and observational
studies that have assessed the outcome of these fractures following
above- or below-elbow immobilisation, bracing and early mobilisation.
We searched multiple electronic databases, related bibliographies and
other studies. We included 27 studies comprising 1629 fractures
in the final analysis. The data relating to the time to radiological
union and the rates of delayed union and nonunion could be pooled
and analysed statistically. We found that early mobilisation produced the shortest radiological
time to union (mean 8.0 weeks) and the lowest mean rate of nonunion
(0.6%). Fractures treated with above- or below-elbow immobilisation
and braces had longer mean radiological times to union (9.2 weeks,
9.2 weeks and 8.7 weeks, respectively) and higher mean rates of
nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically
significant difference in the rate of non- or delayed union between
those treated by early mobilisation and the three forms of immobilisation
(p = 0.142 to p = 1.000, respectively). All the studies had significant
biases, but until a robust randomised controlled trial is undertaken
the best advice for the treatment of undisplaced or partially displaced
nightstick fractures appears to be early mobilisation, with a removable
forearm support for comfort as required. Cite this article:
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
The August 2012 Shoulder &
Elbow Roundup360 looks at: platelet-rich fibrin matrix and the torn rotator cuff; ultrasound, trainees, and ducks out of water; the torn rotator cuff and conservative treatment; Bankart repair and subsequent degenerative change; proprioception after shoulder replacement; surgery for a terrible triad, with reasonable short-term results; and the WORC Index.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The April 2012 Trauma Roundup360 looks at fibula-pro-tibia plating, galeazzi fractures, distal radial fractures in the over 65s, transverse sacral fractures, acute dislocation of the knee, posterior malleolar fractures, immobilising the broken scaphoid, the terrible triad, lower limb amputation after trauma, and whiplash injuries
The use of passive stretching of the elbow after
arthrolysis is controversial. We report the results of open arthrolysis in
81 patients. Prospectively collected outcome data with a minimum
follow-up of one year were analysed. All patients had sustained
an intra-articular fracture initially and all procedures were performed
by the same surgeon under continuous brachial plexus block anaesthesia
and with continuous passive movement (CPM) used post-operatively
for two to three days. CPM was used to maintain the movement achieved
during surgery and passive stretching was not used at any time.
A senior physiotherapist assessed all the patients at regular intervals.
The mean range of movement (ROM) improved from 69° to 109° and the
function and pain of the upper limb improved from 32 to 16 and from
20 to 10, as assessed by the Disabilities of the Arm Shoulder and
Hand score and a visual analogue scale, respectively. The greatest
improvement was obtained in the stiffest elbows: nine patients with
a pre-operative ROM <
30° achieved a mean post-operative ROM
of 92° (55° to 125°). This study demonstrates that in patients with
a stiff elbow after injury, good results may be obtained after open
elbow arthrolysis without using passive stretching during rehabilitation.