Objectives. To study the measurement properties of a joint specific patient
reported outcome measure, a measure of capability and a general
health-related quality of life (HRQOL) tool in a large cohort of
patients with a hip fracture. Methods. Responsiveness and associations between the Oxford Hip Score
(a hip specific measure: OHS), ICEpop CAPability (a measure of capability
in older people: ICECAP-O) and EuroQol EQ-5D (general health-related
quality of life measure: EQ-5D) were assessed using data available
from two large prospective studies. The three outcome measures were assessed
concurrently at a number of fixed follow-up time-points in a consecutive
sequence of patients, allowing direct assessment of change from
baseline, inter-measure associations and validity using a range
of statistical methods. Results. ICECAP-O was not responsive to change. EQ-5D was responsive to
change from baseline, with an estimated standardised effect size
for the two datasets of 0.676 and 0.644 at six weeks and four weeks
respectively; this was almost as responsive to change as OHS (1.14 at
four weeks). EQ-5D correlated strongly with OHS; Pearson correlation
coefficients were 0.74, 0.77 and 0.70 at baseline, four weeks and
four months. EQ-5D is a moderately good predictor of death at 12
months following hip fracture. Furthermore, EQ-5D reported by proxies
(relatives and carers) behaves similarly to self-reported scores. Conclusions. Our findings suggest that a general
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design