The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision hip arthroplasty, and specifically to analyze the available data in order to quantify any associated reduction in the use of allogenic blood transfusion, and the volume which is used. An electronic search of MEDLINE (PubMed), Embase, Scopus, and the Cochrane Library was completed from the date of their inception to 24 February 2022, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were patients aged > 18 years who underwent revision hip arthroplasty when cell salvage was used. Studies in which pre-donated red blood cells were used were excluded. A meta-analysis was also performed using a random effects model with significance set at p = 0.05.Aims
Methods
The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR. We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem.Aims
Methods
Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases.Aims
Methods
Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification. We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment.Aims
Methods
The aim of this study was to report the initial results of the
Exeter V40 stem, which became available in 2000. A total of 540 total hip arthroplasties (THAs) were performed
in our unit using this stem between December 2000 and May 2002.
Our routine protocol is to review patients postoperatively and at
one, five, and ten years following surgery.Aims
Patients and Methods
We report the incidence of radiolucent lines (RLLs) using two
flanged acetabular components at total hip arthroplasty (THA) and
the effect of the Rim Cutter. We performed a retrospective review of 300 hips in 292 patients
who underwent primary cemented THA. A contemporary flanged acetabular
component was used with (group 1) and without (group 2) the use
of the Rim Cutter and the Rimfit acetabular component was used with
the Rim Cutter (group 3). RLLs and clinical outcomes were evaluated
immediately post-operatively and at five years post-operatively.Aims
Patients and Methods
Femoral impaction bone grafting was first developed in 1987 using
morselised cancellous bone graft impacted into the femoral canal
in combination with a cemented, tapered, polished stem. We describe
the evolution of this technique and instrumentation since that time. Between 1987 and 2005, 705 revision total hip arthroplasties
(56 bilateral) were performed with femoral impaction grafting using
a cemented femoral stem. All surviving patients were prospectively
followed for a mean of 14.7 years (9.8 to 28.3) with no loss to
follow-up. By the time of the final review, 404 patients had died.Aims
Patients and Methods
We present a minimum 20-year follow-up study of 382 cemented
Exeter Universal total hip arthroplasties (350 patients) operated
on at a mean age of 66.3 years (17 to 94). All patients received the same design of femoral component, regardless
of the original diagnosis. Previous surgery had been undertaken
for 33 hips (8.6%). During the study period 218 patients with 236
hips (62%) died, 42 hips (11%) were revised and 110 hips (29%) in
96 patients were available for review. The acetabular components
were varied and some designs are now obsolete, however they were
all cemented.Aims
Patients and Methods
We report on the outcome of the Exeter Contemporary flanged cemented
all-polyethylene acetabular component with a mean follow-up of 12
years (10 to 13.9). This study reviewed 203 hips in 194 patients.
129 hips in 122 patients are still A retrospective review was undertaken of a consecutive series
of 203 routine primary cemented total hip arthroplasties (THA) in
194 patients.Aims
Patients and Methods
If patients could recall their physical status
before total hip (THA) or knee arthroplasty (TKA) accurately it
could have valuable applications both clinically and for research.
This study evaluated the accuracy of a patient’s recollection one
year after either THA or TKA using the Oxford hip or knee scores
(OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed
the appropriate score pre-operatively were asked to complete the
score again at a mean of 12.4 months (standard deviation ( While there were no significant differences between the actual
and recalled pre-operative scores (OHS mean difference 0.8, A patient’s recollection of pre-operative pain and function is
inaccurate one year after THA or TKA. Cite this article:
Flexor digitorum longus transfer and medial displacement
calcaneal osteotomy is a well-recognised form of treatment for stage
II posterior tibial tendon dysfunction. Although excellent short-
and medium-term results have been reported, the long-term outcome
is unknown. We reviewed the clinical outcome of 31 patients with
a symptomatic flexible flat-foot deformity who underwent this procedure
between 1994 and 1996. There were 21 women and ten men with a mean
age of 54.3 years (42 to 70). The mean follow-up was 15.2 years
(11.4 to 16.5). All scores improved significantly (p <
0.001).
The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved
from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up.
The mean pain component improved from 12.3 to 35.2 (20 to 40). The
mean function score improved from 35.2 to 45.6 (30 to 50). The mean
visual analogue score for pain improved from 7.3 to 1.3 (0 to 6).
The mean Short Form-36 physical component score was 40.6 ( Cite this article:
Impaction bone grafting for the reconstitution
of bone stock in revision hip surgery has been used for nearly 30 years.
Between 1995 and 2001 we used this technique in acetabular reconstruction,
in combination with a cemented component, in 304 hips in 292 patients
revised for aseptic loosening. The only additional supports used
were stainless steel meshes placed against the medial wall or laterally
around the acetabular rim to contain the graft. All Paprosky grades
of defect were included. Clinical and radiographic outcomes were
collected in surviving patients at a minimum of ten years after
the index operation. Mean follow-up was 12.4 years ( Cite this article:
The technique of femoral cement-in-cement revision
is well established, but there are no previous series reporting its
use on the acetabular side at the time of revision total hip replacement.
We describe the technique and report the outcome of 60 consecutive
acetabular cement-in-cement revisions in 59 patients at a mean follow-up
of 8.5 years (5 to 12). All had a radiologically and clinically
well-fixed acetabular cement mantle at the time of revision. During
the follow-up 29 patients died, but no hips were lost to follow-up.
The two most common indications for acetabular revision were recurrent
dislocation (46, 77%) and to complement femoral revision (12, 20%). Of the 60 hips, there were two cases of aseptic loosening of
the acetabular component (3.3%) requiring re-revision. No other
hip was clinically or radiologically loose (96.7%) at the latest
follow-up. One hip was re-revised for infection, four for recurrent
dislocation and one for disarticulation of a constrained component.
At five years the Kaplan-Meier survival rate was 100% for aseptic
loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause
as the endpoint. These results support the use of cement-in-cement revision on
the acetabular side in appropriate cases. Theoretical advantages
include preservation of bone stock, reduced operating time, reduced
risk of complications and durable fixation.
We report the outcome of the flangeless, cemented all-polyethylene Exeter acetabular component at a mean of 14.6 years (10 to 17) after operation. Of the 263 hips in 243 patients, 122 prostheses are still The cemented all-polyethylene Exeter acetabular component has an excellent long-term survivorship.
Recently the National Patient Safety Agency in the United Kingdom published a report entitled “Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur”. A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.
The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility. We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening. A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft.
The results of treatment of Lisfranc injuries are often unsatisfactory. This retrospective study investigated 46 patients with isolated Lisfranc injuries at a minimum of two years after surgery. Thirteen patients had a poor outcome and had to change employment, or were unable to find work as a result of this injury. The presence of a compensation claim (p = 0.02) and a delay in diagnosis of more than six months were associated with a poor outcome (p = 0.01). There was no association between poor functional outcome and age, gender, mechanism of injury or previous occupation. This study may have medico-legal implications on reporting the prognosis for such injuries, and highlights the importance of prompt diagnosis and treatment.
We used prospective data from 862 total knee and 716 total hip replacements three years after surgery in order to derive and validate a reduced Western Ontario and McMasters University Osteoarthritis Index (WOMAC) function scale. The reduced scale was derived using the advice of clinical experts as well as analysis of data. The scale was tested for validity, reliability and responsiveness. Items which were retained included: ascending stairs, rising from sitting, walking on the flat, getting in or out of a car, putting on socks, rising from bed, and sitting. The reduced and full scales had comparable, moderate correlations with other measures of function, confirming convergent validity. Cronbach’s alpha was high (α >
0.85) with the reduced scale confirming reliability. Responsiveness was greater for the reduced scale (full = 1.4, reduced = 1.6). This reduced version of the WOMAC function scale provides a practical, valid, reliable and responsive alternative to the full function scale for use after total joint replacement. Further work is needed to demonstrate its wider applicability.
We have studied the long-term outcome of 408 primary medial St George Sled unicompartmental arthroplasties of the knee and 531 primary Kinematic total knee arthroplasties using survivorship analysis. The operations were performed by a number of surgeons under the supervision of two consultants at one orthopaedic centre. Prospective clinical assessment was carried out before and at 2, 5, 8, 10, 12 and 15 years after operation. Failure was defined as follows: revision or removal of the implant; the presence of moderate or severe pain; or ‘worst-case’ with all patients lost to follow-up. Cumulative survival rates at ten years were calculated using life tables. The follow-up rate was 97%. At ten years, 25 medial sled arthroplasties and 20 Kinematic knee arthroplasties had been revised. With revision or removal as the survivorship endpoint at ten years there was a success rate of 87.5% for the medial sled and 89.6% for the Kinematic knee arthroplasty. When moderate or severe pain was included these rates became 79.4% for both arthroplasties. There was no statistically significant (p >
0.05) difference between the rates of survival for the two arthroplasties using either of the endpoint criteria. Good or excellent results were recorded for 77.9% of the medial sled knees and 75.1% for the Kinematic knees. The former had 93.8% of cases with a final range of movement in excess of 90° compared with 83.7% for the Kinematic knees (p <
0.01). We conclude that at a single orthopaedic centre in the UK, the St Georg Sled medial compartment arthroplasty for appropriate specific indications offers predictable survivorship at ten years which is comparable with that of the Kinematic total knee arthroplasty.
We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 ± 14.7 to 94 ± 6.8. Radiologically, there was no evidence of acetabular migration. The rate of revision for the femoral component was 8.6%, three being undertaken for loosening and three to allow downsizing of the femoral head. The rate of revision for the acetabular component was 7.1% (five cups). At the time of revision none of the cups was clinically loose, and only required the liner to be changed. The rate of complications was low with no case of deep infection or dislocation, but nine of the 76 hips (11.8%) showed grade-III heterotopic ossification. Previous studies of patients undergoing cemented total hip arthroplasty for the treatment of advanced avascular necrosis have indicated a high incidence of loosening of the acetabular component. Our findings show good medium-term results using the Harris Galante Porous cup for acetabular reconstruction, together with a variety of cemented femoral components, for the treatment of this difficult problem.