This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test.Aims
Methods
Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated.Aims
Methods
Current treatments of prosthetic joint infection (PJI) are minimally effective against The ability of PlySs2 and vancomycin to kill biofilm and colony-forming units (CFUs) on orthopaedic implants were compared using in vitro models. An in vivo murine PJI model of DAIR was used to assess the efficacy of a combination of PlySs2 and vancomycin on periprosthetic bacterial load.Aims
Methods
This study aimed to assess the performance of an automated multiplex polymerase chain reaction (mPCR) technique for rapid diagnosis of native joint septic arthritis Consecutive patients with suspected septic arthritis undergoing aseptic diagnostic joint aspiration were included. The aspirate was used for analysis by mPCR and conventional microbiological analysis. A joint was classed as septic according to modified Newman criteria. Based on receiver operating characteristic (ROC) analysis, the area under the ROC curve (AUC) values of the mPCR and the synovial fluid culture were compared using the z-test. A total of 72 out of 76 consecutive patients (33 women, 39 men; mean age 64 years (22 to 92)) with suspected septic arthritis were included in this study.Aims
Patients and Methods
The diagnosis of periprosthetic joint infection (PJI) remains
demanding due to limitations of all the available diagnostic tests.
The synovial fluid marker, α-defensin, is a promising adjunct for
the assessment of potential PJI. The purpose of this study was to
investigate the qualitative assessment of α-defensin, using Synovasure
to detect or exclude periprosthetic infection in total joint arthroplasty. We studied 50 patients (28 women, 22 men, mean age 65 years;
20 to 89) with a clinical indication for revision arthroplasty who
met the inclusion criteria of this prospective diagnostic study.
The presence of α-defensin was determined using the qualitative
Synovasure test and compared with standard diagnostic methods for
PJI. Based on modified Musculoskeletal Infection Society (MSIS)
criteria, 13 cases were categorised as septic and 36 as aseptic revisions.
One test was inconclusive.Aims
Patients and Methods