We treated 15 patients with atrophic nonunion of a diaphyseal fracture of the humerus with an associated bony defect using an autogenous cancellous bone graft and a plate to bridge the defect. There were nine men and six women with a mean age of 48 years. The mean length of the bony defect was 3 cm. At a mean follow-up of 30 months only one fracture failed to unite. This suggests that, in the presence of a well-vascularised envelope of muscle, the application of an autogenous cancellous bone graft in conjunction with a bridging plate represents a good alternative to more demanding surgical techniques.
We performed ulnar nerve neurolysis and transposition during reconstructive operations on 20 consecutive patients (21 elbows) with neuropathy after the failure of primary treatment of elbow fractures. There were 11 men and nine women with a mean age of 48.3 years. Preoperatively, four elbows were in McGowan stage I, seven in stage II and ten in stage III and the mean Gabel and Amadio ulnar nerve score was 3.2. At a mean follow-up of 32.1 months (24 to 67) we performed comprehensive neurological, functional, electrophysiological and outcome assessments. Patient satisfaction was high with good pain relief and restoration of hand strength and dexterity. The mean Gabel and Amadio score had improved to 6.5, an improvement of 3.3. There were one excellent, 16 good, 2 fair and 2 poor results; both of the last were due to failure of the underlying elbow reconstruction. Even for advanced stage-II and stage-III lesions we achieved good function, return of intrinsic power, and a high rate of patient satisfaction.
We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different medical centres. There were 13 with previous infection, 12 with segmental cortical defects, and 3 were pathological fractures. In 39 cases there had been previous internal fixation and 21 patients had had more than one earlier operation. Union was achieved in 41 patients at an average of six months, although three had required a second bone graft. Two patients had recurrence of infection and in one this resulted in the persistence of nonunion. There were no failures of the implant. All 41 patients with union are now fully weight-bearing, but four have a leg-length discrepancy, one has axial malalignment, and nine have residual stiffness of the knee. These results are surprisingly good, despite the complexity of the initial problem, and appear to confirm the biological and mechanical advantages of the wave plate over the conventional plate for such cases.