Between 1993 and 1996, we undertook 35 Kudo 5 total elbow replacements in a consecutive series of 31 rheumatoid patients. A total of 25 patients (29 procedures) was evaluated at a mean follow-up of six years (5 to 7.5)
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist
We studied retrospectively the results of revision arthroplasty of the elbow
The Souter-Strathclyde prosthesis was
Cubitus varus and valgus are the most common complications of supracondylar and lateral condylar fractures. Various combinations of osteotomy and fixation have been described to correct these deformities but each is associated with significant complications. In this study, we
Instability after arthroplasty of the shoulder
is difficult to correct surgically. Soft-tissue procedures and revision surgery
using unconstrained anatomical components are associated with a
high rate of failure. The purpose of this study was to determine
the results of revision of an unstable anatomical shoulder arthroplasty
to a reverse design prosthesis. Between 2004 and 2007, 33 unstable
anatomical shoulder arthroplasties were revised to a reverse design.
The mean age of the patients was 71 years (53 to 86) and their mean
follow-up was 42 months (25 to 71). The mean time to revision was
26 months (4 to 164). Pain scores improved significantly (pre-operative
visual analogue scale (VAS) of 7.2 (. sd. 1.6); most recent
VAS 2.2 (. sd. 1.9); p = 0.001). There was a statistically
significant increase in mean active forward elevation from 40.2°
(. sd. 27.3) to 97.0° (. sd. 36.2) (p = 0.001). There
was no significant difference in internal (p = 0.93) or external
rotation (p = 0.40). Radiological findings included notching in
five shoulders (15%) and heterotopic ossification of the inferior
capsular region in three (9%). At the last follow-up 31 shoulders
(94%) were stable. The remaining two shoulders dislocated at 2.5
weeks and three months post-operatively, respectively. According
to the Neer rating system, there were 13 excellent (40%), ten satisfactory
(30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty
or anatomical total shoulder replacement for instability
In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was
We describe a new method of stabilising a painful unstable sternoclavicular joint
Malunion is the most common complication of the
distal radius with many modalities of treatment available for such
a problem. The
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation
We reviewed the outcome of 28 patients who had been treated
We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups,
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon
We describe the
The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been
We have
External fixation is useful for the treatment of selected injuries to the hand. Some authors have suggested that external fixation of a phalanx may tether the extensor hood, thereby hindering active movements and predisposing to permanent adhesions. There is no consensus as to the best site for placement of the pin to minimise these problems. This study was performed on cadaver specimens to investigate the influence of the pin site on the range of simulated active movement of the interphalangeal joint. The dorsal midline position produces least interference with the extensor mechanism; radial and ulnar to this, interdigitating oblique fibres prevent a clean longitudinal split in the direction of gliding thus limiting movement of the extensor hood. At the proximal phalanx, positioning of the pin just off the midline avoids the thickening of the proximal median hood, whereas at the middle phalanx, a true midline position utilises the bare area at its base.
Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy. The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint.
In 13 patients (18 fingers) we
We compared the long-term function of subscapularis after the Latarjet procedure