Advertisement for orthosearch.org.uk
Results 1 - 20 of 483
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims. The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Methods. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed. Results. In the assessment of quality, there a was moderate to substantial intraobserver agreement for each element investigated, but interobserver agreement was poor. Morphological features showed weak to moderate agreement across all parameters but improved to significant when responses were reduced. The geometric measurements showed nearly perfect agreement, and the relationship between them and the morphological features showed a dose response across all parameters with moderate to substantial correlations. There were strong correlations between geometric measurements. The Graf classification showed a fair to moderate interobserver agreement, and moderate to substantial intraobserver agreement. Conclusion. This investigation into the reliability of the interpretation of hip ultrasound scans identified the difficulties in defining what is a high-quality ultrasound. We confirmed that geometric measurements are reliably interpreted and may be useful as a further measurement of quality. Morphological features are generally poorly interpreted, but a simpler binary classification considerably improves agreement. As there is a clear dose response relationship between geometric and morphological measurements, the importance of morphology in the diagnosis of hip dysplasia should be questioned. Cite this article: Bone Joint J 2023;105-B(10):1123–1130


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 247 - 253
1 Mar 2023
Pakarinen O Ponkilainen V Uimonen M Haapanen M Helenius I Kuitunen I

Aims. To analyze whether the addition of risk-based criteria to clinical examination-based selective ultrasound screening would increase the rates of early detected cases of developmental dysplasia of the hip (DDH) and decrease the rate of late detected cases. Methods. A systematic review with meta-analysis was performed. The initial search was performed in the PubMed, Scopus, and Web of Science databases in November 2021. The following search terms were used: (hip) AND (ultrasound) AND (luxation or dysplasia) AND (newborn or neonate or congenital). Results. A total of 25 studies were included. In 19 studies, newborns were selected for ultrasound based on both risk factors and clinical examination. In six studies, newborns were selected for ultrasound based on only clinical examination. We did not find evidence indicating that there are differences in the incidence of early- and late-detected DDH, or in the incidence of nonoperatively treated DDH between the risk-based and clinical examination-based groups. The pooled incidence of operatively treated DDH was slightly lower in the risk-based group (0.5 (95% confidence interval (CI) 0.3 to 0.7)) compared with the clinical examination group (0.9 per 1,000 newborns, (95% CI 0.7 to 1.0)). Conclusion. The use of risk factors in conjunction with clinical examination in the selective ultrasound screening of DDH might lead to fewer operatively treated cases of DDH. However, more studies are needed before stronger conclusions can be drawn. Cite this article: Bone Joint J 2023;105-B(3):247–253


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims. Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children. Methods. In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs. Results. We categorized the new bone formation into three stages: stage I (early lengthening), in which there was no obvious callus formation on radiographs and ultrasound; stage II (lengthening), in which radiographs showed low-density callus formation with uneven distribution and three sub-stages could be identified on ultrasound: in Ia punctate callus was visible; in IIb there was linear callus formation which was not yet connected and in IIc there was continuous linear callus. In stage III (healing), the bone ends had united, the periosteum was intact, and the callus had disappeared, as confirmed on radiographs, indicating healed bone. A progressive increase in the number of vertical vessels was noted in the early stages, peaking during stages IIb and IIc, followed by a gradual decline (p < 0.001). Delayed healing involved patients with a prolonged stage IIa or those who regressed to stage IIa from stages IIb or IIc during lengthening. Conclusion. We found that the formation of new bone in paediatric patients undergoing limb lengthening could be reliably evaluated using ultrasound when combined with the radiological findings. This combination enabled an improved assessment of the prognosis, and adjustments to the lengthening protocol. While SMI offered additional insights into angiogenesis within the new bone, its role primarily contributed to the understanding of the microvascular environment rather than directly informing adjustments of treatment. Cite this article: Bone Joint J 2024;106-B(7):751–758


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 498 - 503
1 Apr 2016
Mahadevan D Attwal M Bhatt R Bhatia M

Aims. The objective of this double-blind randomised controlled trial was to assess whether ultrasound guidance improved the efficacy of corticosteroid injections for Morton’s neuroma (MN). . Patients and Methods. In all, 50 feet (40 patients) were recruited for this study but five feet were excluded due to the patients declining further participation. The mean age of the remaining 36 patients (45 feet) was 57.8 years (standard deviation (. sd. ) 12.9) with a female preponderance (33F:12M). All patients were followed-up for 12 months. Treatment was randomised to an ultrasound guided (Group A) or non-ultrasound guided (Group B) injection of 40 mg triamcinolone acetonide and 2 ml 1% lignocaine, following ultrasound confirmation of the diagnosis. . Results. The mean visual analogue score for pain improved significantly in both groups (Group A – from 64 mm, . sd. 25 mm to 29 mm, . sd. 27; Group B – from 69 mm, . sd. 23 mm to 37 mm, . sd. 25) with no statistical difference between them at all time-points. The failure rate within 12 months of treatment was 11/23 (48%) and 12/22 (55%) in Groups A and B, respectively (p = 0.458). The improvement in Manchester Oxford Foot Questionnaire Index and patient satisfaction favoured Group A in the short-term (three months) that almost reached statistical significance (p = 0.059 and 0.066 respectively). However, this difference was not observed beyond three months. . Conclusion. This study has shown that ultrasound guidance did not demonstrably improve the efficacy of corticosteroid injections in patients with MN. Take home message: In the presence of a clear diagnosis of MN, a trained clinician who understands the forefoot anatomy may perform an injection without ultrasound guidance with good and safe results. Cite this article: Bone Joint J 2016;98-B:498–503


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1433 - 1438
1 Oct 2012
Lam W Guo X Leung K Kwong KSC

This study was designed to test the hypothesis that the sensory innervation of bone might play an important role in sensing and responding to low-intensity pulsed ultrasound and explain its effect in promoting fracture healing. In 112 rats a standardised mid-shaft tibial fracture was created, supported with an intramedullary needle and divided into four groups of 28. These either had a sciatic neurectomy or a patellar tendon resection as control, and received the ultrasound or not as a sham treatment. Fracture union, callus mineralisation and remodelling were assessed using plain radiography, peripheral quantitative computed tomography and histomorphology. Daily ultrasound treatment significantly increased the rate of union and the volumetric bone mineral density in the fracture callus in the neurally intact rats (p = 0.025), but this stimulating effect was absent in the rats with sciatic neurectomy. Histomorphology demonstrated faster maturation of the callus in the group treated with ultrasound when compared with the control group. The results supported the hypothesis that intact innervation plays an important role in allowing low-intensity pulsed ultrasound to promote fracture healing


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1399 - 1404
1 Oct 2018
Biedermann R Riccabona J Giesinger JM Brunner A Liebensteiner M Wansch J Dammerer D Nogler M

Aims. The purpose of this study was to analyze the incidence of the different ultrasound phenotypes of developmental dysplasia of the hip (DDH), and to determine their subsequent course. Patients and Methods. A consecutive series of 28 092 neonates was screened and classified according to the Graf method as part of a nationwide surveillance programme, and then followed prospectively. Abnormal hips were followed until they became normal (Graf type I). Type IIb hips and higher grades were treated by abduction in a Tübinger orthosis until normal. Dislocated hips underwent closed or open reduction. Results. Overall, 90.2% of hips were normal at birth. Type IIa hips (8.9%) became normal at a median of six weeks (interquartile range (IQR) 6 to 9). Type IIc and IId hips (0.67%) became normal after ten weeks (IQR 7 to 13). There were 19 type lll and eight type lV hips at baseline. There were 24 closed reductions and one open reduction. No late presentations of DDH were detected within the first five years of life. Conclusion. The incidence of DDH was eight per 1000 live births. The treatment rate was 1% (n = 273). The rate of first operations on the newborn hip was 0.86, and rate of open surgery was 0.04. The cumulative rate of open surgery was 0.07. The authors take the view that early identification and treatment in abduction of all dysplastic hips in early childhood reduces the rate of open reduction and secondary DDH-related surgery later in life. Cite this article: Bone Joint J 2018;100-B:1399–1404


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims. The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture. Methods. All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT. Results. A total of 191 patients were included. A DVT was found preoperatively in 12 patients (6.3%), of which six were proximal. A postoperative DVT was found in 42 patients (22%), of which 27 were proximal. Eight patients (4.2%) had a PE, which was secondary to a DVT in three. None of the 12 patients in whom a vena cava filter was implanted prophylactically had a PE. Multivariate logistic regression analysis indicated that the association with the need for spinal surgery (odds ratio (OR) 19.78 (95% confidence interval (CI) 1.12 to 348.08); p = 0.041), intramedullary nailing of a long bone fracture (OR 4.44 (95% CI 1.05 to 18.86); p = 0.043), an operating time > two hours (OR 3.28 (95% CI 1.09 to 9.88); p = 0.035), and additional trauma surgery (OR 3.1 (95% CI 1.03 to 9.45); p = 0.045) were statistically the most relevant independent predictors of a postoperative DVT. Conclusion. The acknowledgement of the risk factors for the development of a DVT and their weight is crucial to set a threshold for the index of suspicion for this diagnosis by medical staff. We suggest the routine use of the DUS screening for DVT in patients with a pelvic and/or acetabular fracture before and six to ten days after surgery. Cite this article: Bone Joint J 2022;104-B(2):283–289


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1553 - 1555
1 Nov 2014
Paton RW Choudry QA Jugdey R Hughes S

There is controversy whether congenital foot abnormalities are true risk factors for pathological dysplasia of the hip. Previous United Kingdom screening guidelines considered congenital talipes equinovarus (CTEV) to be a risk factor for hip dysplasia, but present guidelines do not. We assessed the potential relationship between pathological dysplasia of the hip and fixed idiopathic CTEV.

We present a single-centre 21-year prospective longitudinal observational study. All fixed idiopathic CTEV cases were classified (Harrold and Walker Types 1 to 3) and the hips clinically and sonographically assessed. Sonographic Graf Type III, IV and radiological irreducible hip dislocation were considered to be pathological hip dysplasia.

Over 21 years there were 139 children with 199 cases of fixed idiopathic CTEV feet. Sonographically, there were 259 normal hips, 18 Graf Type II hips, 1 Graf Type III hip and 0 Graf Type IV hip. There were no cases of radiological or sonographic irreducible hip dislocation.

Fixed idiopathic CTEV should not be considered as a significant risk factor for pathological hip dysplasia. This conclusion is in keeping with the current newborn and infant physical examination guidelines in which the only risk factors routinely screened are family history and breech presentation. Our findings suggest CTEV should not be considered a significant risk factor in pathological dysplasia of the hip.

Cite this article: Bone Joint J 2014;96-B:1553–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1264 - 1266
1 Sep 2005
Paton RW Hinduja K Thomas CD

Of the 34 723 infants born between 1 June 1992 and 31 May 2002, the hips of 2578 with clinical instability or at-risk factors for developmental dysplasia of the hip were imaged by ultrasound. Instability of the hip was present in 77 patients, of whom only 24 (31.2%) had an associated risk factor. From the ‘at-risk’ groups, the overall risk of type-III dysplasia, instability and irreducibility was 1:15 when family history, 1:27 when breech delivery and 1:33 when foot deformity were considered as risk factors. Of those hips which were ultrasonographically stable, 88 had type-III dysplasia. A national programme of selective ultrasound screening of at-risk factors for the diagnosis of hip dislocation or instability alone cannot be recommended because of its low predictive value (1:88). However, the incidence of type-III dysplasia and hip dislocation or dislocatability in the groups with clinical instability, family history, breech position and possibly postural foot deformity as risk factors could justify a programme of selective ultrasound imaging


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1405 - 1409
1 Nov 2009
Mitchell AWM Lee JC Healy JC

The use of ultrasound in the diagnosis and management of disorders of the tendo Achillis is discussed. Some of the pathological processes which occur in Achilles tendinopathy can be identified by ultrasound, which may also be used to direct local treatment


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1526 - 1532
1 Nov 2017
Tarride JE Hopkins RB Blackhouse G Burke N Bhandari M Johal H Guyatt GH Busse JW

Aims. This 501-patient, multi-centre, randomised controlled trial sought to establish the effect of low-intensity, pulsed, ultrasound (LIPUS) on tibial shaft fractures managed with intramedullary nailing. We conducted an economic evaluation as part of this trial. Patients and Methods. Data for patients’ use of post-operative healthcare resources and time taken to return to work were collected and costed using publicly available sources. Health-related quality of life, assessed using the Health Utilities Index Mark-3 (HUI-3), was used to derive quality-adjusted life years (QALYs). Costs and QALYs were compared between LIPUS and control (a placebo device) from a payer and societal perspective using non-parametric bootstrapping. All costs are reported in 2015 Canadian dollars unless otherwise stated. Results. With a cost per device of $3,995, the mean cost was significantly higher for patients treated with LIPUS versus placebo from a payer (mean increase = $3647, 95% confidence interval (CI) $3244 to $4070; p < 0.001) or a societal perspective (mean increase = $3425, 95% CI $1568 to $5283; p < 0.001). LIPUS did not provide a significant benefit in terms of QALYs gained (mean difference = 0.023 QALYs, 95% CI -0.035 to 0.069; p = 0.474). Incremental cost-effectiveness ratios of LIPUS compared with placebo were $155 433/QALY from a payer perspective and $146 006/QALY from a societal perspective. Conclusion. At the current price, LIPUS is not cost-effective for fresh tibial fractures managed with intramedullary nailing. Cite this article: Bone Joint J 2017;99-B:1526–32


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 767 - 773
1 Nov 1989
Terjesen T Bredland T Berg V

The hips of 1000 newborn babies were examined clinically and by ultrasonography. The ultrasound assessment was based on measurements of the coverage of the femoral head by the bony acetabular roof, and this parameter was called the Bony Rim Percentage (BRP). The mean BRP was 55.3% in girls and 57.2% in boys, a significant difference. Clinical instability occurred in 0.7% of the newborn babies, and all of the unstable hips had a BRP below the lower limit of normal. All infants with normal clinical findings and suspected abnormal hips based on ultrasound were followed up; in all but two the hips became normal spontaneously. We conclude that ultrasonography, using the measurements of femoral head coverage, is appropriate for screening the newborn, is reliable in differentiating between a true and a false positive Ortolani sign, and that hip dysplasia which is not clinically demonstrable at birth can be detected by ultrasound. Ultrasound should replace radiography as the routine method of following up high-risk infants and those with suspicious signs


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 886 - 890
1 Aug 2002
Holen KJ Tegnander A Bredland T Johansen OJ Sæther OD Eik-Nes SH Terjesen T

The aim of this study was to evaluate whether universal (all neonates) or selective (neonates belonging to the risk groups) ultrasound screening of the hips should be recommended at birth. We carried out a prospective, randomised trial between 1988 and 1992, including all newborn infants at our hospital. A total of 15 529 infants was randomised to either clinical screening and ultrasound examination of all hips or clinical screening of all hips and ultrasound examination only of those at risk. The effect of the screening was assessed by the rate of late detection of congenital or developmental hip dysplasia in the two groups. During follow-up of between six and 11 years, only one late-detected hip dysplasia was seen in the universal group, compared with five in the subjective group, representing a rate of 0.13 and 0.65 per 1000, respectively. The difference in late detection between the two groups was not statistically significant (p = 0.22). When clinical screening is of high quality, as in our study, the effect of an additional ultrasound examination, measured as late-presenting hip dysplasia, is marginal. Under such circumstances, we consider that universal ultrasound screening is not necessary, but recommend selective ultrasound screening for neonates with abnormal or suspicious clinical findings and those with risk factors for hip dysplasia


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 144 - 147
1 Mar 1983
Howie D Chatterton B Hone M

This paper reports a prospective study of the value of ultrasonography in detecting lesions of the lumbar spine in patients with compressive sciatica. The measurements of the diameter of the spinal canal obtained by using ultrasound were compared with the findings at operation in 17 patients in whom a total of 50 sites were examined. The ultrasound beam failed to penetrate the spinal canal at 15 sites and at only 10 of the remaining 35 sites did the ultrasound correctly detect narrowing. It is concluded that ultrasonography is unreliable in identifying the site of compression of the spinal cord and nerve roots. The technical limitations and the probable causes of failure of the technique are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1170 - 1173
1 Nov 2000
Hübner U Schlicht W Outzen S Barthel M Halsband H

We compared the results of primary ultrasonographic examination of 163 children with 224 suspected fractures with the subsequent radiological findings. The aim was to assess the value of ultrasound in the diagnosis of fractures in children. We found a good correlation for fractures of the long bones of the upper and lower limbs. Ultrasound was most reliable for the detection of simple femoral and humeral diaphyseal fractures and fractures of the forearm. It was less dependable for compound injuries and fractures adjacent to joints, lesions of the small bones of the hand and foot, non-displaced epiphyseal fractures (Salter-Harris type 1) or those with a fracture line of less than 1mm. We were able to distinguish several types of fracture in which the use of ultrasound alone gave reliable information and further radiography was unnecessary. We discuss the advantages and disadvantages of skeletal ultrasonographic studies in children


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 984 - 988
1 Jul 2014
Pullinger M Southorn T Easton V Hutchinson R Smith RP Sanghrajka AP

Congenital Talipes Equinovarus (CTEV) is one of the most common congenital limb deformities. We reviewed the records of infants who had received treatment for structural CTEV between 1 January 2007 and 30 November 2012. This was cross-referenced with the prenatal scans of mothers over a corresponding period of time. We investigated the sensitivity, specificity, and positive and negative predictive values of the fetal anomaly scan for the detection of CTEV and explored whether the publication of Fetal Anomaly Screening Programme guidelines in 2010 affected the rate of detection. During the study period there were 95 532 prenatal scans and 34 373 live births at our hospital. A total of 37 fetuses with findings suggestive of CTEV were included in the study, of whom 30 were found to have structural CTEV at birth. The sensitivity of screening for CTEV was 71.4% and the positive predictive value was 81.1%. The negative predictive value and specificity were more than 99.5%. There was no significant difference between the rates of detection before and after publication of the guidelines (p = 0.5). We conclude that a prenatal fetal anomaly ultrasound screening diagnosis of CTEV has a good positive predictive value enabling prenatal counselling. The change in screening guidance has not affected the proportion of missed cases. This information will aid counselling parents about the effectiveness and accuracy of prenatal ultrasound in diagnosing CTEV. Cite this article: Bone Joint J 2014;96-B:984–8


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1077 - 1082
1 Sep 2000
Shimazaki A Inui K Azuma Y Nishimura N Yamano Y

We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the distraction site by radiography, measurement of the bone mineral density (BMD), mechanical testing, and histology. In the second part in six rabbits using fast distraction (waiting period 0 days; distraction rate 1.5 mm/12 hours; distraction period seven days) the site was evaluated radiologically. Half of the animals (35) had received ultrasound to their right leg (30mW/cm. 2. ) for 20 minutes daily after ceasing distraction (ultrasound group), while rigid fixation only was maintained in the other half (control group). With normal distraction, the hard callus area, as shown by radiography, the BMD, and the findings on mechanical testing, were significantly greater in those receiving ultrasound than in the control group. Histological analysis showed no tissue damage attributable to exposure to ultrasound. With fast distraction, immature bone regeneration was observed radiologically in the control group, while bone maturation was achieved in the ultrasound group. We conclude that ultrasound can accelerate bone maturation in distraction osteogenesis in rabbits, even in states of poor callotasis