In this study a combination of autologous chondrocyte implantation (ACI) and the osteochondral autograft transfer system (OATS) was used and evaluated as a
Cancer-induced bone diseases are often associated with increased bone resorption and pathological fractures. In recent years, osteoprotective agents such as bisphosphonates have been studied extensively and have been shown to inhibit cancer-related bone resorption in experimental and clinical studies. The third-generation bisphosphonate, ibandronate (BM 21.0955), is a potent compound for controlling tumour osteolysis and hypercalcaemia in rats bearing Walker 256 carcinosarcoma. We have studied the effect of ibandronate given as an interventional
The
The intermittent administration of parathyroid hormone (PTH) increases the formation of bone by stimulating osteoblastic activity. Our study evaluates the possibility that intermittent
We have developed a new drug-delivery system using reconstituted bone xenograft to treat chronic osteomyelitis. This material, which has the capabilities of osteoinduction and osteoconduction, was supplemented with up to 2000 times the minimum inhibitory concentration of gentamicin against Staphylococcus aureus to prepare a gentamicin-reconstituted bone xenograft-composite (G-RBX-C). In a rabbit model, we evaluated the release of gentamicin from this composite in vivo, its capability for induction of ectopic bone and the repair of segmental defects of the radius. There was a high level of concentration of antibiotics, which was sustained for at least ten days. In the study of induction of ectopic bone, there was abundant woven bone in the G-RBX-C group two weeks after operation. At 16 weeks after implantation of G-RBX-C the radial defects had been repaired, with the formation of lamellar bone and recanalisation of the marrow cavity. Our findings suggest that G-RBX-C may be useful in the
Immobilisation causes denervation-like changes in the motor endplates, decreases the content of IGF-I, and increases the number of IGF-I receptors in the spinal cord. In the rat we investigated whether similar changes occur after a fracture of the midshaft of the femur which had been treated by intramedullary fixation with adequate or undersized pins. A more pronounced reduction in muscle wet weight was seen after fixation by undersized pins as well as decreased ash density of the ipsilateral tibia which did not completely return to normal within the 12-week experimental period. The nicotinic cholinergic receptors in the motor endplates of tibialis anterior were increased (p <
0.01) and there was a significant increase (p <
0.02) in IGF-I receptors in the lumbar spinal cord ipsilateral to the fracture after
In a series of 12 patients with inoperable gastric carcinoma who had
The use of a composite osteochondral device for simulating partial hemiarthroplasty was examined. The device was composed of a polyvinyl alcohol hydrogel and a titanium fibre mesh, acting as artificial cartilage and as porous artificial bone, respectively. The titanium fibre mesh was designed to act as an interface material, allowing firm attachment to both the polyvinyl alcohol gel (through injection moulding) and the femoral joint surface (through bony ingrowth). We implanted 22 of these devices into canine femoral heads. Histological findings from the acetabular cartilage and synovial membrane, as well as the attachment of the prosthesis to bone, were examined up until one year after operation. No marked pathological changes were found and firm attachment of the device to the underlying bone was confirmed. The main potential application for this device is for partial surface replacement of the femoral head after osteonecrosis. Other applications could include articular resurfacing and the replacement of intervertebral discs.
The efficacy of β-tricalcium phosphate (β-TCP) loaded with bone morphogenetic protein-2 (BMP-2)-gene-modified bone-marrow mesenchymal stem cells (BMSCs) was evaluated for the repair of experimentally-induced osteonecrosis of the femoral head in goats. Bilateral early-stage osteonecrosis was induced in adult goats three weeks after ligation of the lateral and medial circumflex arteries and delivery of liquid nitrogen into the femoral head. After core decompression, porous β-TCP loaded with BMP-2 gene- or β-galactosidase (gal)-gene-transduced BMSCs was implanted into the left and right femoral heads, respectively. At 16 weeks after implantation, there was collapse of the femoral head in the untreated group but not in the BMP-2 or β-gal groups. The femoral heads in the BMP-2 group had a normal density and surface, while those in the β-gal group presented with a low density and an irregular surface. Histologically, new bone and fibrous tissue were formed in the macropores of the β-TCP. Sixteen weeks after implantation, lamellar bone had formed in the BMP-2 group, but there were some empty cavities and residual fibrous tissue in the β-gal group. The new bone volume in the BMP-2 group was significantly higher than that in the β-gal group. The maximum compressive strength and Young’s modulus of the repaired tissue in the BMP-2 group were similar to those of normal bone and significantly higher than those in the β-gal group. Our findings indicate that porous β-TCP loaded with BMP-2-gene-transduced BMSCs are capable of repairing early-stage, experimentally-induced osteonecrosis of the femoral head and of restoring its mechanical function.
We have investigated the anatomy of the proximal part of the ulna to assess its influence on the use of plates in the management of fractures at this site. We examined 54 specimens from cadavers. The mean varus angulation in the proximal third was 17.5° (11° to 23°) and the mean anterior deviation 4.5° (1° to 14°). These variations must be considered when applying plates to the dorsal surface of the ulna for Monteggia-type fractures. A pre-operative radiograph of the contralateral elbow may also be of value.
We have developed a new drug delivery system using porous apatite-wollastonite glass ceramic (A-W GC) to treat osteomyelitis. A-W GC (porosity, 70% and 20% to 30%), or porous hydroxyapatite (HA) blocks (porosity 35% to 48%) used as controls, were soaked in mixtures of two antibiotics, isepamicin sulphate (ISP) and cefmetazole (CMZ) under high vacuum. We evaluated the release concentrations of the antibiotics from the blocks. The bactericidal concentration of ISP from A-W GC was maintained for more than 42 days, but that from HA decreased to below the detection limit after 28 days. The concentrations of CMZ from both materials were lower than those of ISP. An in vivo study using rabbit femora showed that an osseous concentration of ISP was maintained at eight weeks after implantation. Osteoconduction of the A-W GC block was good. Four patients with infected hip arthroplasties and one with osteomyelitis of the tibia have been treated with the new delivery system with excellent results.
Various chemicals are commonly used as adjuvant
We studied 51 patients with osteo-articular tuberculosis who were divided into two groups. Group I comprised 31 newly-diagnosed patients who were given first-line antituberculous
Corticosteroids are prescribed for the
The discrepancy between successful experimental studies of cartilage repair and the clinical results is unexplained. We have evaluated the effect of metabolic alterations in joint homeostasis owing to an articular defect on the outcome of cartilage repair using tissue engineering methods. We used 21 adolescent Dutch goats divided into three groups. The control knees were left untreated while the contralateral knee was randomised to receive either no
We evaluated the possible induction of a systemic immune response to increase anti-tumour activity by the re-implantation of destructive tumour tissue treated by liquid nitrogen in a murine osteosarcoma (LM8) model. The tumours were randomised to
Platelet-leucocyte gel (PLG), a new biotechnological blood product, has hitherto been used primarily to treat chronic ulcers and to promote soft-tissue and bone regeneration in a wide range of medical fields. In this study, the antimicrobial efficacy of PLG against Staphylococcus aureus (ATCC 25923) was investigated in a rabbit model of osteomyelitis. Autologous PLG was injected into the tibial canal after inoculation with Staph. aureus. The prophylactic efficacy of PLG was evaluated by microbiological, radiological and histological examination. Animal groups included a
Reported rates of dislocation in hip hemiarthroplasty
(HA) for the
Extracorporeal shock-wave (ESW)