Aims. The primary aim of this study was to assess the independent association of the coronavirus disease 2019 (COVID-19) on postoperative mortality for patients undergoing orthopaedic and
The spread of viral diseases such as HIV has highlighted the importance of protecting medical personnel against contamination from blood. We have assessed the frequency of the perforation of surgical gloves during orthopaedic and
Weightbearing instructions after musculoskeletal injury or orthopaedic surgery are a key aspect of the rehabilitation pathway and prescription. The terminology used to describe the weightbearing status of the patient is variable; many different terms are used, and there is recognition and evidence that the lack of standardized terminology contributes to confusion in practice. A consensus exercise was conducted involving all the major stakeholders in the patient journey for those with musculoskeletal injury. The consensus exercise primary aim was to seek agreement on a standardized set of terminology for weightbearing instructions.Aims
Methods
External fixation is widely used in orthopaedic
and
Calcium sulphate (CaSO4) is a resorbable material
that can be used simultaneously as filler of a dead space and as
a carrier for the local application of antibiotics. Our aim was
to describe the systemic exposure and the wound fluid concentrations
of vancomycin in patients treated with vancomycin-loaded CaSO4 as
an adjunct to the routine therapy of bone and joint infections. A total of 680 post-operative blood and 233 wound fluid samples
were available for analysis from 94 implantations performed in 87
patients for various infective indications. Up to 6 g of vancomycin
were used. Non-compartmental pharmacokinetic analysis was performed
on the data from 37 patients treated for an infection of the hip.Aims
Patients and Methods
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
The poor reporting and use of statistical methods in orthopaedic papers has been widely discussed by both clinicians and statisticians. A detailed review of research published in general orthopaedic journals was undertaken to assess the quality of experimental design, statistical analysis and reporting. A representative sample of 100 papers was assessed for compliance to CONSORT and STROBE guidelines and the quality of the statistical reporting was assessed using a validated questionnaire. Overall compliance with CONSORT and STROBE guidelines in our study was 59% and 58% respectively, with very few papers fulfilling all criteria. In 37% of papers patient numbers were inadequately reported; 20% of papers introduced new statistical methods in the ‘results’ section not previously reported in the ‘methods’ section, and 23% of papers reported no measurement of error with the main outcome measure. Taken together, these issues indicate a general lack of statistical rigour and are consistent with similar reviews undertaken in a number of other scientific and clinical research disciplines. It is imperative that the orthopaedic research community strives to improve the quality of reporting; a failure to do so could seriously limit the development of future research.
Drug therapy forms an integral part of the management
of many orthopaedic conditions. However, many medicines can produce
serious adverse reactions if prescribed inappropriately, either
alone or in combination with other drugs. Often these hazards are
not appreciated. In response to this, the European Union recently
issued legislation regarding safety measures which member states
must adopt to minimise the risk of errors of medication. In March 2014 the Medicines and Healthcare products Regulatory
Agency and NHS England released a Patient Safety Alert initiative
focussed on errors of medication. There have been similar initiatives
in the United States under the auspices of The National Coordinating
Council for Medication Error and The Joint Commission on the Accreditation
of Healthcare Organizations. These initiatives have highlighted
the importance of informing and educating clinicians. Here, we discuss common drug interactions and contra-indications
in orthopaedic practice. This is germane to safe and effective clinical
care. Cite this article:
Using inaccurate quotations can propagate misleading
information, which might affect the management of patients. The
aim of this study was to determine the predictors of quotation inaccuracy
in the peer-reviewed orthopaedic literature related to the scaphoid.
We randomly selected 100 papers from ten orthopaedic journals. All references
were retrieved in full text when available or otherwise excluded.
Two observers independently rated all quotations from the selected
papers by comparing the claims made by the authors with the data
and expressed opinions of the reference source. A statistical analysis
determined which article-related factors were predictors of quotation
inaccuracy. The mean total inaccuracy rate of the 3840 verified
quotes was 7.6%. There was no correlation between the rate of inaccuracy
and the impact factor of the journal. Multivariable analysis identified
the journal and the type of study (clinical, biomechanical, methodological,
case report or review) as important predictors of the total quotation
inaccuracy rate. We concluded that inaccurate quotations in the peer-reviewed
orthopaedic literature related to the scaphoid were common and slightly
more so for certain journals and certain study types. Authors, reviewers
and editorial staff play an important role in reducing this inaccuracy.
Recent recommendations by the National Institute
for Health and Care Excellence (NICE) suggest that all patients undergoing
elective orthopaedic surgery should be assessed for the risk of
venous thromboembolism (VTE). Little is known about the incidence of symptomatic VTE after
elective external fixation. We studied a consecutive series of adult
patients who had undergone elective Ilizarov surgery without routine
pharmacological prophylaxis to establish the incidence of symptomatic
VTE. A review of a prospectively maintained database of consecutive
patients who were treated between October 1998 and February 2011
identified 457 frames in 442 adults whose mean age was 42.6 years
(16.0 to 84.6). There were 425 lower limb and 32 upper limb frames.
The mean duration of treatment was 25.7 weeks (1.6 to 85.3). According to NICE guidelines all the patients had at least one
risk factor for VTE, 246 had two, 172 had three and 31 had four
or more. One patient (0.23%) developed a pulmonary embolus after surgery
and was later found to have an inherited thrombophilia. There were
27 deaths, all unrelated to VTE. The cost of providing VTE prophylaxis according to NICE guidelines
in this group of patients would be £89 493.40 (£195.80 per patient)
even if the cheapest recommended medication was used. The rate of symptomatic VTE after Ilizarov surgery was low despite
using no pharmacological prophylaxis. This study leads us to question
whether NICE guidelines are applicable to these patients. Cite this article:
In order to assess the efficacy of inspection and accreditation by the Specialist Advisory Committee for higher surgical training in orthopaedic surgery and trauma, seven training regions with 109 hospitals and 433 Specialist Registrars were studied over a period of two years. There were initial deficiencies in a mean of 14.8% of required standards (10.3% to 19.2%). This improved following completion of the inspection, with a mean residual deficiency in 8.9% (6.5% to 12.7%.) Overall, 84% of standards were checked, 68% of the units improved and training was withdrawn in 4%. Most units (97%) were deficient on initial assessment. Moderately good rectification was achieved but the process of follow-up and collection of data require improvement. There is an imbalance between the setting of standards and their implementation. Any major revision of the process of accreditation by the new Post-graduate Medical Education and Training Board should recognise the importance of assessment of training by direct inspection on site, of the relationship between service and training, and the advantage of defining mandatory and developmental standards.