Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 513 - 518
1 Apr 2014
Terrier A Ston J Larrea X Farron A

The three-dimensional (3D) correction of glenoid erosion is critical to the long-term success of total shoulder replacement (TSR). In order to characterise the 3D morphology of eroded glenoid surfaces, we looked for a set of morphological parameters useful for TSR planning. We defined a scapular coordinates system based on non-eroded bony landmarks. The maximum glenoid version was measured and specified in 3D by its orientation angle. Medialisation was considered relative to the spino-glenoid notch. We analysed regular CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When the maximum version of OA shoulders was higher than 10°, the orientation was not only posterior, but extended in postero-superior (35%), postero-inferior (6%) and anterior sectors (4%). The medialisation of the glenoid was higher in OA than normal shoulders. The orientation angle of maximum version appeared as a critical parameter to specify the glenoid shape in 3D. It will be very useful in planning the best position for the glenoid in TSR. Cite this article: Bone Joint J 2014;96-B:513–18


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1377 - 1382
1 Oct 2013
Walch G Mesiha M Boileau P Edwards TB Lévigne C Moineau G Young A

Osteoarthritis results in changes in the dimensions of the glenoid. This study aimed to assess the size and radius of curvature of arthritic glenoids. A total of 145 CT scans were analysed, performed as part of routine pre-operative assessment before total shoulder replacement in 91 women and 54 men. Only patients with primary osteoarthritis and a concentric glenoid were included in the study. The CT scans underwent three-dimensional (3D) reconstruction and were analysed using dedicated computer software. The measurements consisted of maximum superoinferior height, anteroposterior width and a best-fit sphere radius of curvature of the glenoid.

The mean height was 40.2 mm (sd 4.9), the mean width was 29 mm (sd 4.3) and the mean radius of curvature was 35.4 mm (sd 7.8). The measurements were statistically different in men and women and had a Gaussian distribution with marked variation. All measurements were greater than the known values in normal subjects.

With current shoulder replacement systems using a unique backside radius of curvature for the glenoid component, there is a risk of undertaking excessive reaming to adapt the bone to the component resulting in sacrifice of subchondral bone or under-reaming and instability of the component due to a ’rocking horse‘ phenomenon.

Cite this article: Bone Joint J 2013;95-B:1377–82.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 237 - 241
1 Feb 2014
Miyake J Shimada K Oka K Tanaka H Sugamoto K Yoshikawa H Murase T

We retrospectively assessed the value of identifying impinging osteophytes using dynamic computer simulation of CT scans of the elbow in assisting their arthroscopic removal in patients with osteoarthritis of the elbow. A total of 20 patients were treated (19 men and one woman, mean age 38 years (19 to 55)) and followed for a mean of 25 months (24 to 29). We located the impinging osteophytes dynamically using computerised three-dimensional models of the elbow based on CT data in three positions of flexion of the elbow. These were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively to 9° (0° to 25°) post-operatively, and the mean flexion improved from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively. The mean Mayo Elbow Performance Score improved from 62 (30 to 85) to 95 (70 to 100) post-operatively. All patients had pain in the elbow pre-operatively which disappeared or decreased post-operatively. According to their Mayo scores, 14 patients had an excellent clinical outcome and six a good outcome; 15 were very satisfied and five were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients with osteoarthritis of the elbow. Cite this article: Bone Joint J 2014;96-B:237–41


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 953 - 956
1 Jul 2018
Erşen A Atalar AC Bayram S Demirel M Tunalı O Demirhan M

Aims

The present study aimed to investigate the long-term functional results of scapulothoracic fusion using multifilament cables in patients with facioscapulohumeral dystrophy (FSHD) to identify if the early improvement from this intervention is maintained.

Patients and Methods

We retrospectively investigated the long-term outcomes of 13 patients with FSHD (18 shoulders) in whom scapulothoracic fusion using multifilament cables was performed between 2004 and 2007. These patients have previously been reported at a mean of 35.5 months (24 to 87). There were eight men and five women with a mean age of 26 years. Their mean length of follow-up of our current study was 128 months (94 to 185). To evaluate long-term functional results, the range of shoulder flexion and abduction, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores were analyzed with a comparison of preoperatively, interim and at the final outcomes. The fusion was examined radiographically in all.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims

Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases).

Methods

They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients.

A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation.

The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients.

Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty.

Cite this article: Bone Joint J 2015;97-B:1377–84.