Aims. The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Methods. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods. Results. The coating released gentamicin at > 10 × minimum inhibitory concentration (MIC) for sensitive staphylococcal
We have assessed the different adhesive properties
of some of the most common bacteria associated with periprosthetic
joint infection on various types of ultra high molecular Weight
Polyethylene (UHMWPE). Quantitative in vitro analysis
of the adhesion of biofilm producing
The aim of this study was to evaluate whether
coating titanium discs with selenium in the form of sodium selenite decreased
bacterial adhesion of Staphylococcus aureus and Staph.
epidermidis and impeded osteoblastic cell growth. In order to evaluate bacterial adhesion, sterile titanium discs
were coated with increasing concentrations of selenium and incubated
with bacterial solutions of Staph. aureus (ATCC
29213) and Staph. epidermidis (DSM 3269) and stained
with Safranin-O. The effect of selenium on osteoblastic cell growth
was also observed. The adherence of MG-63 cells on the coated discs
was detected by staining with Safranin-O. The proportion of covered
area was calculated with imaging software. The tested Staph. aureus
Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity. We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.Aims
Methods
Aims. The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI). Patients and Methods. Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society. Results. A total of 25 patients had a confirmed PJI. In 20 cases of monomicrobial PJI, the PCR products could be perfectly matched with the 16S/28S rRNA genes specific for different species of bacteria provided by sequence analysis. Of the five polymicrobial cases of PJI, 16S/28S rRNA PCR sequence analysis failed to identify the concordant bacteria species. In the 189 control patients, there was one false-positive RT-PCR result. The sensitivity and specificity of the molecular diagnosis method were 100% (95% confidence interval (CI) 85.7 to 100) and 99.5% (95% CI 97.1 to 99.9), respectively, whereas the positive and negative predictive values of PCR were 96.1% (95% CI 79.6 to 99.9) and 100% (95% CI 98.1 to 100), respectively. The PCR results were significantly better than serological diagnostic methods (p = 0.004 and p = 0.010 for ESR and CRP, respectively), the synovial fluid white blood cell (WBC) count (p = 0.036), and percentage of polymorphonuclear cells (PMN%) (p = 0.014). Conclusion. Stepwise RT-PCR and sequence analysis of the 16S/28S rRNA carried out under stringent laboratory conditions achieved highly sensitive and specific results for the differentiation between aseptic and septic joints undergoing arthroplasty. Sequence analysis successfully identified bacterial
The success rates of two-stage revision arthroplasty for infection have evolved since their early description. The implementation of internationally accepted outcome criteria led to the readjustment of such rates. However, patients who do not undergo reimplantation are usually set aside from these calculations. The aim of this study was to investigate the outcomes of two-stage revision arthroplasty when considering those who do not undergo reimplantation, and to investigate the characteristics of this subgroup. A retrospective cohort study was conducted. Patients with chronic hip or knee periprosthetic joint infection (PJI) treated with two-stage revision between January 2010 and October 2018, with a minimum follow-up of one year, were included. Variables including demography, morbidity, microbiology, and outcome were collected. The primary endpoint was the eradication of infection. Patients who did not undergo reimplantation were analyzed in order to characterize this subgroup better.Aims
Methods
Biopsy of the periprosthetic tissue is an important diagnostic tool for prosthetic joint infection (PJI) as it enables the detection of the responsible microorganism with its sensitivity to antibiotics. We aimed to investigate how often the bacteria identified in the tissue analysis differed between samples obtained from preoperative biopsy and intraoperative revision surgery in cases of late PJI; and whether there was a therapeutic consequence. A total of 508 patients who required revision surgery of total hip arthroplasty (THA) (n = 231) or total knee arthroplasty (TKA) (n = 277) because of component loosening underwent biopsy before revision surgery. The tissue samples collected at biopsy and during revision surgery were analyzed according to the criteria of the Musculoskeletal Infection Society (MSIS).Aims
Methods
Fungal prosthetic joint infections (PJIs) are rare and account for about 1% of total PJIs. Our aim was to present clinical and microbiological results in treating these patients with a two-stage approach and antifungal spacers. We retrospectively reviewed our institutional database and identified 26 patients with positive fungal cultures and positive Musculoskeletal Infection Society (MSIS) criteria for PJI who were treated between 2009 and 2017. We identified 18 patients with total hip arthroplasty (THA) and eight patients with total knee arthroplasty (TKA). The surgical and antifungal treatment, clinical and demographic patient data, complications, relapses, and survival were recorded and analyzed.Aims
Patients and Methods
Surgical site infection (SSI) is a common complication of surgery
with an incidence of about 1% in the United Kingdom. Sutures can
lead to the development of a SSI, as micro-organisms can colonize
the suture as it is implanted. Triclosan-coated sutures, being antimicrobical,
were developed to reduce the rate of SSI. Our aim was to assess
whether triclosan-coated sutures cause a reduction in SSIs following
arthroplasty of the hip and knee. This two-arm, parallel, double-blinded study involved 2546 patients
undergoing elective total hip (THA) and total knee arthroplasty
(TKA) at three hospitals. A total of 1323 were quasi-randomized
to a standard suture group, and 1223 being quasi-randomized to the
triclosan-coated suture group. The primary endpoint was the rate
of SSI at 30 days postoperatively.Aims
Patients and Methods
To investigate the bone penetration of intravenous antibiotic
prophylaxis with flucloxacillin and gentamicin during hip and knee
arthroplasty, and their efficacy against Bone samples from the femoral head, neck and acetabulum were
collected from 18 patients undergoing total hip arthroplasty (THA)
and from the femur and tibia in 21 patients during total knee arthroplasty
(TKA). The concentration of both antibiotics in the samples was
analysed using high performance liquid chromatography. Penetration
was expressed as a percentage of venous blood concentration. The
efficacy against common infecting organisms was measured against
both the minimum inhibitory concentration 50, and the more stringent epidemiological
cutoff value for resistance (ECOFF).Aims
Patients and Methods
The aim of this study was to identify the incidence of positive
cultures during the second stage of a two-stage revision arthroplasty
and to analyse the association between positive cultures and an
infection-free outcome. This single-centre retrospective review of prospectively collected
data included patients with a periprosthetic joint infection (PJI)
of either the hip or the knee between 2013 and 2015, who were treated
using a standardised diagnostic and therapeutic algorithm with two-stage
exchange. Failure of treatment was assessed according to a definition
determined by a Delphi-based consensus. Logistic regression analysis
was performed to assess the predictors of positive culture and risk
factors for failure. The mean follow-up was 33 months (24 to 48).Aims
Patients and Methods
Infection following total hip or knee arthroplasty is a serious
complication. We noted an increase in post-operative infection in
cases carried out in temporary operating theatres. We therefore
compared those cases performed in standard and temporary operating
theatres and examined the deep periprosthetic infection rates. A total of 1223 primary hip and knee arthroplasties were performed
between August 2012 and June 2013. A total of 539 (44%) were performed
in temporary theatres. The two groups were matched for age, gender,
body mass index and American Society of Anesthesiologists grade.Aims
Patients and methods
The interaction between surgical lighting and laminar airflow
is poorly understood. We undertook an experiment to identify any
effect contemporary surgical lights have on laminar flow and recommend
practical strategies to limit any negative effects. Neutrally buoyant bubbles were introduced into the surgical field
of a simulated setup for a routine total knee arthroplasty in a
laminar flow theatre. Patterns of airflow were observed and the
number of bubbles remaining above the surgical field over time identified.
Five different lighting configurations were assessed. Data were analysed
using simple linear regression after logarithmic transformation.Aims
Materials and Methods
Older patients with multiple medical co-morbidities
are increasingly being offered and undergoing total joint arthroplasty
(TJA). These patients are more likely to require intensive care
support, following surgery. We prospectively evaluated the need
for intensive care admission and intervention in a consecutive series
of 738 patients undergoing elective hip and knee arthroplasty procedures.
The mean age was 60.6 years (18 to 91; 440 women, 298 men. Risk
factors, correlating with the need for critical care intervention,
according to published guidelines, were analysed to identify high-risk
patients who would benefit from post-operative critical care monitoring.
A total of 50 patients (6.7%) in our series required critical care
level interventions during their hospital stay. Six independent
multivariate clinical predictors were identified (p <
0.001)
including a history of congestive heart failure (odds ratio (OR)
24.26, 95% confidence interval (CI) 9.51 to 61.91), estimated blood
loss >
1000 mL (OR 17.36, 95% CI 5.36 to 56.19), chronic obstructive
pulmonary disease (13.90, 95% CI 4.78 to 40.36), intra-operative
use of vasopressors (OR 8.10, 95% CI 3.23 to 20.27), revision hip
arthroplasty (OR 2.71, 95% CI 1.04 to 7.04) and body mass index
>
35 kg/m2 (OR 2.70, 95% CI 123 to 5.94). The model was
then validated against an independent, previously published data
set of 1594 consecutive patients. The use of this risk stratification
model can be helpful in predicting which high-risk patients would
benefit from a higher level of monitoring and care after elective
TJA and aid hospitals in allocating precious critical care resources. Cite this article:
Biofilm-associated infections in wounds or on implants are difficult to treat. Eradication of the bacteria is nearly always impossible, despite the use of specific antibiotics. The bactericidal effects of high-energy extracorporeal shock waves on The biofilm-cultured washers were exposed to low-energy shock waves at 0.16 mJ/mm2 for 500 impulses. The washers were then treated with cefuroxime, rifampicin and fosfomycin, both alone and in combination. All tests were carried out in triplicate. Viable cells were counted to determine the bactericidal effect. The control groups of We conclude that shock waves combined with antibiotics could be tested in an
Antibiotic prophylaxis is routinely administered during joint replacement surgery and may predispose patients to
We reviewed systematically the published evidence on the effectiveness of antibiotic prophylaxis for the reduction of wound infection in patients undergoing total hip and total knee replacement. Publications were identified using the Cochrane Library, MEDLINE, EMBASE and CINAHL databases. We also contacted authors to identify unpublished trials. We included randomised controlled trials which compared any prophylaxis with none, the administration of systemic antibiotics with that of those in cement, cephalosporins with glycopeptides, cephalosporins with penicillin-derivatives, and second-generation with first-generation cephalosporins. A total of 26 studies (11 343 participants) met the inclusion criteria. Methodological quality was variable. In a meta-analysis of seven studies (3065 participants) antibiotic prophylaxis reduced the absolute risk of wound infection by 8% and the relative risk by 81% compared with no prophylaxis (p <
0.00001). No other comparison showed a significant difference in clinical effect. Antibiotic prophylaxis should be routine in joint replacement but the choice of agent should be made on the basis of cost and local availability.
Bone cements produced by different manufacturers vary in their mechanical properties and antibiotic elution characteristics. Small changes in the formulation of a bone cement, which may not be apparent to surgeons, can also affect these properties. The supplier of Palacos bone cement with added gentamicin changed in 2005. We carried out a study to examine the mechanical characteristics and antibiotic elution of Schering-Plough Palacos, Heraeus Palacos and Depuy CMW Smartset bone cements. Both Heraeus Palacos and Smartset bone cements performed significantly better than Schering-Plough Palacos in terms of mechanical characteristics, with and without additional vancomycin (p <
0.001). All cements show a deterioration in flexural strength with increasing addition of vancomycin, albeit staying above ISO minimum levels. Both Heraeus Palacos and Smartset elute significantly more gentamicin cumulatively than Schering-Plough Palacos. Smartset elutes significantly more vancomycin cumulatively than Heraeus Palacos. The improved antibiotic elution characteristics of Smartset and Heraeus Palacos are not associated with a deterioration in mechanical properties. Although marketed as the ‘original’ Palacos, Heraeus Palacos has significantly altered mechanical and antibiotic elution characteristics compared with the most commonly-used previous version.
We wished to estimate the incidence of surgical-site infection (SSI) after total hip replacement (THR) and hemiarthroplasty and its strength of association with major risk factors. The SSI surveillance service prospectively gathered clinical, operative and infection data on inpatients from 102 hospitals in England during a four-year period. The overall incidence of SSI was 2.23% for 16 291 THRs, 4.97% for 5769 hemiarthroplasty procedures, 3.68% for 2550 revision THRs and 7.6% for 198 revision hemiarthroplasties.