Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 678 - 682
1 May 2013
Holinka J Pilz M Kubista B Presterl E Windhager R

The aim of this study was to evaluate whether coating titanium discs with selenium in the form of sodium selenite decreased bacterial adhesion of Staphylococcus aureus and Staph. epidermidis and impeded osteoblastic cell growth. In order to evaluate bacterial adhesion, sterile titanium discs were coated with increasing concentrations of selenium and incubated with bacterial solutions of Staph. aureus (ATCC 29213) and Staph. epidermidis (DSM 3269) and stained with Safranin-O. The effect of selenium on osteoblastic cell growth was also observed. The adherence of MG-63 cells on the coated discs was detected by staining with Safranin-O. The proportion of covered area was calculated with imaging software. The tested Staph. aureus strain showed a significantly reduced attachment on titanium discs with 0.5% (p = 0.011) and 0.2% (p = 0.02) selenium coating. Our test strain from Staph. epidermidis showed a highly significant reduction in bacterial adherence on discs coated with 0.5% (p = 0.0099) and 0.2% (p = 0.002) selenium solution. There was no inhibitory effect of the selenium coating on the osteoblastic cell growth. Selenium coating is a promising method to reduce bacterial attachment on prosthetic material. Cite this article: Bone Joint J 2013;95-B:678–82


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 908 - 915
1 May 2021
O’Donnell JA Wu M Cochrane NH Belay E Myntti MF James GA Ryan SP Seyler TM

Aims

Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm.

Methods

We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 296 - 302
1 Mar 2018
Sprowson† AP Jensen C Parsons N Partington P Emmerson K Carluke I Asaad S Pratt R Muller S Ahmed I Reed MR

Aims

Surgical site infection (SSI) is a common complication of surgery with an incidence of about 1% in the United Kingdom. Sutures can lead to the development of a SSI, as micro-organisms can colonize the suture as it is implanted. Triclosan-coated sutures, being antimicrobical, were developed to reduce the rate of SSI. Our aim was to assess whether triclosan-coated sutures cause a reduction in SSIs following arthroplasty of the hip and knee.

Patients and Methods

This two-arm, parallel, double-blinded study involved 2546 patients undergoing elective total hip (THA) and total knee arthroplasty (TKA) at three hospitals. A total of 1323 were quasi-randomized to a standard suture group, and 1223 being quasi-randomized to the triclosan-coated suture group. The primary endpoint was the rate of SSI at 30 days postoperatively.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1519 - 1524
1 Nov 2015
Salih S Paskins A Nichol T Smith T Hamer A

We investigated whether the indentation of bone cement spacers used in revision of infected joint arthroplasty with a MacDonald dissector increased the elution of antibiotic in vitro. A total of 24 cement discs containing either 0.17 g (0.88% w/w), 0.25 g (1.41% w/w), or 0.33 g (1.75% w/w) gentamicin of constant size were made. Of these, 12 were indented with the dissector. Each disc was immersed in ammonium acetate buffer in a sealed container, and fluid from each container was sampled at zero, one, three, six, 24, 48 and 72 hours and at one, and two weeks. The concentration of gentamicin in the fluid was analysed using high performance liquid chromatography mass spectrometry.

The fluid sampled at 72 hours from the indented discs containing 0.17 g gentamicin (0.88% w/w) contained a mean of 113 mcg/ml (90.12 to 143.5) compared with 44.5 mcg/ml (44.02 to 44.90) in the fluid sampled from the plain discs (p = 0.012). In discs containing 0.33 g gentamicin (1.75% w/w), the concentration eluted from the indented discs at 72 hours was a mean of 316 mcg/ml (223 to 421) compared with a mean of 118 mcg/ml (100 to 140) from the plain discs (p < 0.001).

At two weeks, these significant differences persisted. At nine weeks the indented discs eluted a greater concentration for all gentamicin doses, but the difference was only significant for the discs containing 0.17 g (0.88% w/w, p = 0.006). However if the area under the curve is taken as a measure of the total antibiotic eluted, the indented discs eluted more gentamicin than the plain discs for the 0.17 g (0.88% w/w, p = 0.031), the 0.25 g (1.41% w/w, p < 0.001) and the 0.33 g (1.75% w/w, p < 0.001) discs.

When preparing antibiotic spacers for use in staged revision arthroplasty surgery we recommend indenting the spacer with a MacDonald dissector to increase the elution of antibiotic.

Cite this article: Bone Joint J 2015;97-B:1519–24.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 91 - 95
1 Jan 2011
Jensen CD Steval A Partington PF Reed MR Muller SD

Rivaroxaban has been recommended for routine use as a thromboprophylactic agent in patients undergoing lower-limb arthroplasty. However, trials supporting its use have not fully evaluated the risks of wound complications. This study of 1048 total hip/knee replacements records the rates of return to theatre and infection before and after the change from a low molecular weight heparin (tinzaparin) to rivaroxaban as the agent of chemical thromboprophylaxis in patients undergoing lower-limb arthroplasty. During a period of 13 months, 489 consecutive patients undergoing lower-limb arthroplasty received tinzaparin and the next 559 consecutive patients received rivaroxaban as thromboprophylaxis.

Nine patients in the control (tinzaparin) group (1.8%, 95% confidence interval 0.9 to 3.5) returned to theatre with wound complications within 30 days, compared with 22 patients in the rivaroxaban group (3.94%, 95% confidence interval 2.6 to 5.9). This increase was statistically significant (p = 0.046). The proportion of patients who returned to theatre and became infected remained similar (p = 0.10).

Our study demonstrates the need for further randomised controlled clinical trials to be conducted to assess the safety and efficacy of rivaroxaban in clinical practice, focusing on the surgical complications as well as the potential prevention of venous thromboembolism.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 636 - 644
1 May 2009
Eriksson BI Kakkar AK Turpie AGG Gent M Bandel T Homering M Misselwitz F Lassen MR

A once-daily dose of rivaroxaban 10 mg, an oral, direct Factor Xa inhibitor, was compared with enoxaparin 40 mg subcutaneously once daily for prevention of venous thromboembolism in three studies of patients undergoing elective hip and knee replacement (RECORD programme).

A pooled analysis of data from these studies (n = 9581) showed that rivaroxaban was more effective than enoxaparin in reducing the incidence of the composite of symptomatic venous thromboembolism and all-cause mortality at two weeks (0.4% vs 0.8%, respectively, odds ratio 0.44; 95% confidence interval 0.23 to 0.79; p = 0.005), and at the end of the planned medication period (0.5% vs 1.3%, respectively; odds ratio 0.38; 95% confidence interval 0.22 to 0.62; p < 0.001). The rate of major bleeding was similar at two weeks (0.2% for both) and at the end of the planned medication period (0.3% vs 0.2%).

Rivaroxaban started six to eight hours after surgery was more effective than enoxaparin started the previous evening in preventing symptomatic venous thromboembolism and all-cause mortality, without increasing major bleeding.