Percutaneous
Aims. The aim of this study was to assess the accuracy of
We undertook a retrospective study investigating
the accuracy and safety of percutaneous pedicle screws placed under
fluoroscopic guidance in the lumbosacral junction and lumbar spine.
The CT scans of patients were chosen from two centres: European
patients from University Medical Center Hamburg-Eppendorf, Germany,
and Asian patients from the University of Malaya, Malaysia. Screw
perforations were classified into grades 0, 1, 2 and 3. A total
of 880 percutaneous pedicle screws from 203 patients were analysed:
614 screws from 144 European patients and 266 screws from 59 Asian
patients. The mean age of the patients was 58.8 years (16 to 91)
and there were 103 men and 100 women. The total rate of perforation
was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade
3 perforations. The rate of perforation in Europeans was 10.4% and
in Asians was 8.6%, with no significant difference between the two
(p = 0.42). The rate of perforation was the highest in S1 (19.4%)
followed by L5 (14.9%). The accuracy and safety of percutaneous
pedicle screw placement are comparable to those cited in the literature
for the open method of
Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)).Aims
Methods
Continuous technical improvement in spinal surgical procedures, with the aim of enhancing patient outcomes, can be assisted by the deployment of advanced technologies including navigation, intraoperative CT imaging, and surgical robots. The latest generation of robotic surgical systems allows the simultaneous application of a range of digital features that provide the surgeon with an improved view of the surgical field, often through a narrow portal. There is emerging evidence that procedure-related complications and intraoperative blood loss can be reduced if the new technologies are used by appropriately trained surgeons. Acceptance of the role of surgical robots has increased in recent years among a number of surgical specialities including general surgery, neurosurgery, and orthopaedic surgeons performing major joint arthroplasty. However, ethical challenges have emerged with the rollout of these innovations, such as ensuring surgeon competence in the use of surgical robotics and avoiding financial conflicts of interest. Therefore, it is essential that trainees aspiring to become spinal surgeons as well as established spinal specialists should develop the necessary skills to use robotic technology safely and effectively and understand the ethical framework within which the technology is introduced. Traditional and more recently developed platforms exist to aid skill acquisition and surgical training which are described. The aim of this narrative review is to describe the role of surgical robotics in spinal surgery, describe measures of proficiency, and present the range of training platforms that institutions can use to ensure they employ confident spine surgeons adequately prepared for the era of robotic spinal surgery. Cite this article:
With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety. Cite this article:
Minimally invasive transforaminal lumbar interbody fusion (MITLIF)
has been well validated in overweight and obese patients who are
consequently subject to a higher radiation exposure. This prospective
multicentre study aimed to investigate the efficacy of a novel lumbar
localisation system for MITLIF in overweight patients. The initial study group consisted of 175 patients. After excluding
49 patients for various reasons, 126 patients were divided into
two groups. Those in Group A were treated using the localisation
system while those in Group B were treated by conventional means.
The primary outcomes were the effective radiation dosage to the
surgeon and the exposure time.Aims
Patients and Methods
Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery. A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed.Aims
Methods
We compared the accuracy, operating time and radiation exposure
of the introduction of iliosacral screws using O-arm/Stealth Navigation
and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first
sacral body (S1) of ten human cadavers, four men and six women.
The mean age was 77 years (58 to 85). Screws were introduced using
a standard technique into the left side of S1 using C-Arm fluoroscopy
and then into the right side using O-Arm/Stealth Navigation. The
radiation was measured on the surgeon by dosimeters placed under
a lead thyroid shield and apron, on a finger, a hat and on the cadavers.Aims
Materials and Methods
Tuberculosis (TB) remains endemic in many parts
of the developing world and is increasingly seen in the developed world
due to migration. A total of 1.3 million people die annually from
the disease. Spinal TB is the most common musculoskeletal manifestation,
affecting about 1 to 2% of all cases of TB. The coexistence of HIV,
which is endemic in some regions, adds to the burden and the complexity
of management. This review discusses the epidemiology, clinical presentation,
diagnosis, impact of HIV and both the medical and surgical options
in the management of spinal TB. Cite this article:
The aim of this study was to compare the outcomes of surgery
using growing rods in patients with severe A review of a multicentre EOS database identified 107 children
with severe EOS (major curve ≥ 90°) treated with growing rods before
the age of ten years with a minimum follow-up of two years and three
or more lengthening procedures. From the same database, 107 matched
controls with moderate EOS were identified.Aims
Patients and Methods
The aim of this study was a quantitative analysis of a surgeon’s
learning curve for scoliosis surgery and the relationship between
the surgeon’s experience and post-operative outcomes, which has
not been previously well described. We have investigated the operating time as a function of the
number of patients to determine a specific pattern; we analysed
factors affecting the operating time and compared intra- and post-operative
outcomes. We analysed 47 consecutive patients undergoing scoliosis
surgery performed by a single, non-trained scoliosis surgeon. Operating time
was recorded for each of the four parts of the procedures: dissection,
placement of pedicle screws, reduction of the deformity and wound
closure.Aims
Patients and Methods
We evaluated the oncological and functional outcome
of 18 patients, whose malignant bone tumours were excised with the
assistance of navigation, and who were followed up for more than
three years. There were 11 men and seven women, with a mean age
of 31.8 years (10 to 57). There were ten operations on the pelvic
ring and eight joint-preserving limb salvage procedures. The resection
margins were free of tumour in all specimens. The tumours, which
were stage IIB in all patients, included osteosarcoma, high-grade
chondrosarcoma, Ewing’s sarcoma, malignant fibrous histiocytoma
of bone, and adamantinoma. The overall three-year survival rate
of the 18 patients was 88.9% (95% confidence interval (CI) 75.4
to 100). The three-year survival rate of the patients with pelvic malignancy
was 80.0% (95% CI 55.3 to 100), and of the patients with metaphyseal
malignancy was 100%. The event-free survival was 66.7% (95% CI 44.9
to 88.5). Local recurrence occurred in two patients, both of whom
had a pelvic malignancy. The mean Musculoskeletal Tumor Society
functional score was 26.9 points at a mean follow-up of 48.2 months
(22 to 79). We suggest that navigation can be helpful during surgery for
musculoskeletal tumours; it can maximise the accuracy of resection
and minimise the unnecessary sacrifice of normal tissue by providing
precise intra-operative three-dimensional radiological information.
We reviewed 212 consecutive patients with adolescent
idiopathic scoliosis who underwent posterior spinal arthrodesis
using all pedicle screw instrumentation in terms of clinical, radiological
and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51
patients), the correction was performed over two rods using bilateral
segmental pedicle screws. In Group 2 (161 patients), the correction
was performed over one rod using unilateral segmental pedicle screws
with the second rod providing stability of the construct
through two-level screw fixation at proximal and distal ends. The
mean age at surgery was
14.8 years in both groups. Comparison between groups showed no significant
differences with regard to age and Risser grade at surgery, pre-
and post-operative scoliosis angle, coronal Cobb correction, length
of hospital stay and SRS scores. Correction of upper thoracic curves
was significantly better in Group 1 (p = 0.02). Increased surgical time
and intra-operative blood loss was recorded in Group 1 (p <
0.001
and p = 0.04, respectively). The implant cost was reduced by mean
35% in Group 2 due to the lesser number of pedicle screws. Unilateral and bilateral pedicle screw techniques have both achieved
excellent deformity correction in adolescent patients with idiopathic
scoliosis, which was maintained at two-year follow-up. This has
been associated with high patient satisfaction and low complication
rates.
The spinal manifestations of neurofibromatosis include cervicothoracic kyphosis, in which scalloping of the vertebral body and erosion of the pedicles may render conventional techniques of fixation impossible. We describe a case of cervicothoracic kyphosis managed operatively with a vascularised fibular graft anteriorly across the apex of the kyphus, followed by a long posterior construct using translaminar screws, which allow segmental fixation in vertebral bodies where placement of the pedicle screws was impracticable.
Metastatic epidural compression of the spinal cord is a significant source of morbidity in patients with systemic cancer. With improved oncological treatment, survival in these patients is improving and metastatic cord compression is encountered increasingly often. The treatment is mostly palliative. Surgical management involves early circumferential decompression of the cord with concomitant stabilisation of the spine. Patients with radiosensitive tumours without cord compression benefit from radiotherapy. Spinal stereotactic radiosurgery and minimally invasive techniques, such as vertebroplasty and kyphoplasty, with or without radiofrequency ablation, are promising options for treatment and are beginning to be used in selected patients with spinal metastases. In this paper we review the surgical management of patients with metastatic epidural spinal cord compression.