Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The
The study aimed to assess the clinical outcomes of arthroscopic debridement and partial excision in patients with traumatic central tears of the triangular fibrocartilage complex (TFCC), and to identify prognostic factors associated with unfavourable clinical outcomes. A retrospective analysis was conducted on patients arthroscopically diagnosed with Palmer 1 A lesions who underwent arthroscopic debridement and partial excision from March 2009 to February 2021, with a minimum follow-up of 24 months. Patients were assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, Mayo Wrist Score (MWS), and visual analogue scale (VAS) for pain. The poor outcome group was defined as patients whose preoperative and last follow-up clinical score difference was less than the minimal clinically important difference of the DASH score (10.83). Baseline characteristics, arthroscopic findings, and radiological factors (ulnar variance, MRI, or arthrography) were evaluated to predict poor clinical outcomes.Aims
Methods
The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis.Aims
Methods
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.Aims
Methods
We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.Aims
Methods
The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear. Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.Aims
Methods
Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful. Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment.Aims
Methods
The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a fracture of the distal radius.
Radiographs of the 367 patients were assessed by two independent
reviewers. Four measurements of displacement of the fracture were recorded
and the inter-observer correlation assessed using the intra-class
correlation coefficient.Aims
Patients and Methods
The aims of this study were: firstly, to investigate the influence
of the thickness of cartilage at the sigmoid notch on the inclination
of the distal radioulnar joint (DRUJ), and secondly, to compare
the sensitivity and specificity of MRI with plain radiographs for
the assessment of the inclination of the articular surface of the
DRUJ in the coronal plane. Contemporaneous MRI images and radiographs of 100 wrists from
98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male,
53%) with no history of a fracture involving the wrist or surgery
to the wrist, were reviewed. The thickness of the cartilage at the
sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ
were determined. Aims
Patients and Methods
We conducted an observational radiographic study
to determine the inter- and intra-observer reliability of the AO classification
of fractures of the distal radius. Plain posteroanterior and lateral
radiographs of 456 patients with an acute fracture of the distal
radius were classified by a consultant orthopaedic hand specialist
and two specialist trainees, and the k coefficient for the inter-
and intra-observer reliability of the type, group and subgroup classification
was calculated. Only the type of fracture (A, B or C) was found to provide substantial
intra-observer reliability (k type 0.65). The inclusion
of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer
reliability to fair (kgroup 0.29, ksubgroup =
0.28) and the intra-observer reliability to moderate (kgroup 0.53,
ksubgroup 0.49). Disagreement was found to arise between
specific subgroups, which may be amenable to clarification. Cite this article:
We performed a systematic review of the current literature regarding
the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. We initially identified 1305 studies, and 406 were found to be
duplicates. After exclusion criteria were applied, seven studies
were included. Outcomes extracted included pre- and post-operative
pain visual analogue scores, range of movement (ROM), strength of
pinch and grip, satisfaction and patient reported outcome measures
(PROMs). Clinical and radiological complications were recorded.
The results are presented in three groups based on the design of
the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA),
pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene
(MoP)).Aims
Materials and Methods
Our purpose was to determine the quality of current randomised
controlled trials (RCTs) in hand surgery using standardised metrics. Based on five-year mean impact factors, we selected the six journals
that routinely publish studies of upper extremity surgery. Using
a journal-specific search query, 62 RCTs met our inclusion criteria.
Then three blinded reviewers used the Jadad and revised Coleman Methodology
Score (RCMS) to assess the quality of the manuscripts.Aims
Materials and Methods
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article:
We performed a retrospective study to determine
the effect of osteoporosis on the functional outcome of osteoporotic
distal radial fractures treated with a volar locking plate. Between
2009 and 2012 a total of 90 postmenopausal women with an unstable
fracture of the distal radius treated with a volar locking plate
were studied. Changes in the radiological parameters of 51 patients
with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 ( We found that osteoporosis does not have a negative effect on
the functional outcome and additional analysis did not show a correlation
between T-score and outcome. Cite this article:
We hypothesised that the use of pulsed electromagnetic
field (PEMF) bone growth stimulation in acute scaphoid fractures
would significantly shorten the time to union and reduce the number
of nonunions in a randomised, double-blind, placebo-controlled multicentre
trial. A total of 102 patients (78 male, 24 female; mean age 35
years (18 to 77)) from five different medical centres with a unilateral
undisplaced acute scaphoid fracture were randomly allocated to PEMF
(n = 51) or placebo (n = 51) and assessed with regard to functional
and radiological outcomes (multiplanar reconstructed CT scans) at
6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing
did not differ significantly between the active PEMF group and the
placebo group. We concluded that the addition of PEMF bone growth
stimulation to the conservative treatment of acute scaphoid fractures
does not accelerate bone healing. Cite this article:
Damage to the cartilage of the distal radioulnar
joint frequently leads to pain and limitation of movement, therefore repair
of this joint cartilage would be highly desirable. The purpose of
this study was to investigate the fixation of scaffold in cartilage
defects of this joint as part of matrix-assisted regenerative autologous
cartilage techniques. Two techniques of fixation of collagen scaffolds,
one involving fibrin glue alone and one with fibrin glue and sutures, were
compared in artificially created cartilage defects of the distal
radioulnar joint in a human cadaver. After being subjected to continuous
passive rotation, the methods of fixation were evaluated for cover
of the defect and pull out force. No statistically significant differences were found between the
two techniques for either cover of the defect or integrity of the
scaffold. However, a significantly increased mean pull out force
was found for the combined procedure, 0.665 N (0.150 to 1.160) This suggests that although successful fixation of a collagen
type I/III scaffold in a distal radioulnar joint cartilage defect
is feasible with both forms of fixation, fixation with glue and
sutures is preferable. Cite this article: