Over a 13-year period we studied all patients who underwent major hip and knee surgery and were diagnosed with objectively confirmed symptomatic venous thromboembolism, either deep venous thrombosis or non-fatal pulmonary embolism, within six months after surgery. Low-molecular-weight heparin had been given while the patients were in hospital. There were 5607 patients. The cumulative incidence of symptomatic venous thromboembolism was 2.7% (150 of 5607), of which 1.1% had developed pulmonary embolism, 1.5% had deep venous thrombosis and 0.6% had both. Patients presented with deep venous thrombosis at a median of 24 days and pulmonary embolism at 17 days after
Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p <
0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before
We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were changed prior to cementation. In addition, gloves were changed in both groups whenever there was a visible puncture. Only outer gloves were investigated. Contamination was tested by impression of gloved fingers on blood agar and culture plates were subsequently incubated at 37°C for 48 hours. The number of colonies and types of organisms were recorded. Glove perforation was assessed using the water test. The incidence of perforation and contamination was significantly lower in the study group compared with the control group. Changing gloves at regular intervals is an effective way to decrease the incidence of glove perforation and bacterial contamination during total hip arthroplasty.