Drug therapy forms an integral part of the management
of many orthopaedic conditions. However, many medicines can produce
serious adverse reactions if prescribed inappropriately, either
alone or in combination with other drugs. Often these hazards are
not appreciated. In response to this, the European Union recently
issued legislation regarding safety measures which member states
must adopt to minimise the risk of errors of medication. In March 2014 the Medicines and Healthcare products Regulatory
Agency and NHS England released a Patient Safety Alert initiative
focussed on errors of medication. There have been similar initiatives
in the United States under the auspices of The National Coordinating
Council for Medication Error and The Joint Commission on the Accreditation
of Healthcare Organizations. These initiatives have highlighted
the importance of informing and educating clinicians. Here, we discuss common drug interactions and contra-indications
in orthopaedic practice. This is germane to safe and effective clinical
care. Cite this article:
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic shock syndrome (TSS) may occur. We retrospectively reviewed all patients who underwent external
fixation between 1997 and 2012 in our limb lengthening and reconstruction
programme. A total of eight patients (seven female and one male)
with a mean age of 20 years (5 to 45) in which pin/wire track infections
became limb- or life-threatening were identified. Of these, four
were due to TSS and four to NF. Their management is described. A
satisfactory outcome was obtained with early diagnosis and aggressive
medical and surgical treatment. Clinicians caring for patients who have external fixation and
in whom infection has developed should be aware of the possibility
of these more serious complications. Early diagnosis and aggressive
treatment are required in order to obtain a satisfactory outcome. Cite this article:
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
The risk of venous thromboembolism in patients following arthroplasty may be reduced by continuing chemical thromboprophylaxis for up to 35 days post-operatively. This prospective cohort study investigated the compliance of 40 consecutive consenting patients undergoing lower limb arthroplasty with self-administration of a recommended subcutaneous chemotherapeutic agent for six weeks after surgery. Compliance was assessed by examination of the patient for signs of injection, number of syringes used, and a self-report diary at the end of the six-week period. A total of 40 patients, 15 men and 25 women, were recruited. One woman was excluded because immediate post-operative complications prevented her participation. Self-administration was considered feasible in 87% of patients (95% confidence interval (CI) 76 to 98) at the time of discharge. Among this group of 34 patients, 29 (85%) were compliant (95% CI 73 to 97). Patients can learn to self-administer subcutaneous injections of thromboprophylaxis, and compliance with extended prophylaxis to six weeks is good.
This study was undertaken to evaluate the safety and efficacy of retrievable inferior vena cava filters in high-risk orthopaedic patients. A total of 58 patients had a retrievable inferior vena cava filter placed as an adjunct to chemical and mechanical prophylaxis, most commonly for a history of previous deep-vein thrombosis or pulmonary embolism, polytrauma, or expected prolonged immobilisation. In total 56 patients (96.6%) had an uncomplicated post-operative course. Two patients (3.4%) died in the peri-operative period for unrelated reasons. Of the 56 surviving patients, 50 (89%) were available for follow-up. A total of 32 filters (64%) were removed without complication at a mean of 37.8 days (4 to 238) after placement. There were four filters (8%) which were retained because of thrombosis at the filter site, and four (8%) were retained because of incorporation of the filter into the wall of the inferior vena cava. In ten cases (20%) the retrievable filter was left in place to continue as primary prophylaxis. No patient had post-removal thromboembolic complications. A retrievable inferior vena cava filter, as an adjunct to chemical and mechanical prophylaxis, was a safe and effective means of reducing the acute risk of pulmonary embolism in this high-risk group of patients. Although most filters were removed without complications, thereby avoiding the long-term complications that have plagued permanent indwelling filters, a relatively high percentage of filters had to be left
We reviewed 234 benign solitary schwannomas treated between 1984 and 2004. The mean age of the patients was 45.2 years (11 to 82). There were 170 tumours (73%) in the upper limb, of which 94 (40%) arose from the brachial plexus or other nerves within the posterior triangle of the neck. Six (2.6%) were located within muscle or bone. Four patients (1.7%) presented with tetraparesis due to an intraspinal extension. There were 198 primary referrals (19 of whom had a needle biopsy in the referring unit) and in these patients the tumour was excised. After having surgery or an open biopsy at another hospital, a further 36 patients were seen because of increased neurological deficit, pain or incomplete excision. In these, a nerve repair was performed in 18 and treatment for pain or paralysis was offered to another 14. A tender mass was found in 194 (98%) of the primary referrals. A Tinel-like sign was recorded in 155 (81%). Persistent spontaneous pain occurred in 60 (31%) of the 194 with tender mass, impairment of cutaneous sensibility in 39 (20%), and muscle weakness in 24 (12%). After apparently adequate excision, two tumours recurred. No case of malignant transformation was seen.
We present seven patients with recurrent haemarthroses after total knee arthroplasty, caused by an inherent platelet function defect. These patients developed painful knee swelling, persistent bleeding and/or wound breakdown, a platelet factor 3 availability defect being identified in all cases. Surgical exploration, with joint debridement, lavage and synovectomy, was performed in four patients who did not improve with conservative therapy. Histopathological examination of synovium revealed a focal synovial reaction with histiocytic infiltration, and occasional foreign-body giant cells. One patient required an early revision because of aseptic loosening of their tibial component. The condition was treated by single-donor platelet transfusions with good results. The diagnosis, management, and relevance of this disorder are discussed.
Bone-marrow oedema can occur both in isolation and in association with necrosis of bone, but it has not been shown whether each respond to the same methods of treatment. We treated 16 patients with isolated oedema and 17, in which it was associated with necrosis of the proximal femur, with the prostacyclin derivative iloprost, which has been shown to be effective in the idiopathic form. The Harris hip score, the range of movement, the extent of the oedema as measured by MRI, pain on a visual analogue scale and patient satisfaction were recorded before and subsequent to treatment. In both groups, we were able to show a significant improvement (p <
0.001) in these observations during the period of follow-up indicating that iloprost will produce clinical improvement in both circumstances.
Using a computer-based quality assurance program, we analysed peri-operative data on 160 patients undergoing one-stage bilateral hip or knee arthroplasties under regional anaesthesia with routine anaesthetic monitoring and only using peripheral intravenous access for peri-operative safety. We monitored defined intra-operative adverse events such as hypotension, myocardial ischaemia, arrhythmias, hypovolaemia, hypertension and early post-operative complications. We also determined post-operative hip and knee function, and patient satisfaction with different aspects of the anaesthetic management. Those patients undergoing one-stage bilateral arthroplasties were matched according to a cross-stratification which used three variables (American Society of Anesthesiologists’ physical status scoring system, age and joint replaced) to patients undergoing unilateral hip or knee arthroplasties. Serious intra-operative adverse events were, with the exception of intra-operative hypotension, very infrequent in patients undergoing bilateral (nine adverse events) as well as unilateral arthroplasties (five adverse events). Early post-operative complications were also infrequent in both groups. However, the risks of receiving a heterologous blood transfusion (odds ratio 2.5; 95% confidence interval (CI) 1.3 to 5.0, estimated by exact conditional logistic regression) or vasoactive drugs (odds ratio 3.9; 95% CI 2.0 to 7.8) were significantly greater for patients undergoing bilateral operations. Patient satisfaction with anaesthesia was high; all patients who underwent the one-stage bilateral operation would choose the same anaesthetic technique again.