Accurate, reproducible outcome measures are essential
for the evaluation of any orthopaedic procedure, in both clinical
practice and research. Commonly used patient-reported outcome measures (PROMs) have
drawbacks such as ‘floor’ and ‘ceiling’ effects, limitations of
worldwide adaptability and an inability to distinguish pain from
function. They are also unable to measure the true outcome of an
intervention rather than a patient’s perception of that outcome. Performance-based functional outcome tools may address these
problems. It is important that both clinicians and researchers are
aware of these measures when dealing with high-demand patients,
using a new intervention or implant, or testing a new rehabilitation
protocol. This article provides an overview of some of the clinically-validated
performance-based functional outcome tools used in the assessment
of patients undergoing hip and knee surgery. Cite this article:
Two-stage exchange arthroplasty is the most common definitive treatment for prosthetic joint infection (PJI) in the USA. Complications that occur during treatment are often not considered. The purpose of this study was to analyze complications in patients undergoing two-stage exchange for infected total knee arthroplasty (TKA) and determine when they occur. We analyzed all patients that underwent two-stage exchange arthroplasty for treatment of PJI of the knee from January 2010 to December 2018 at a single institution. We categorized complications as medical versus surgical. The intervals for complications were divided into: interstage; early post-reimplantation (three months); and late post-reimplantation (three months to minimum one year). Minimum follow-up was one year. In total, 134 patients underwent a first stage of a two-stage exchange. There were 69 males and 65 females with an mean age at first stage surgery of 67 years (37 to 89). Success was based on the new Musculoskeletal Infection Society (MSIS) definition of success reporting.Aims
Methods
The objective of this study was to compare early postoperative
functional outcomes and time to hospital discharge between conventional
jig-based total knee arthroplasty (TKA) and robotic-arm assisted
TKA. This prospective cohort study included 40 consecutive patients
undergoing conventional jig-based TKA followed by 40 consecutive
patients receiving robotic-arm assisted TKA. All surgical procedures
were performed by a single surgeon using the medial parapatellar
approach with identical implant designs and standardized postoperative inpatient
rehabilitation. Inpatient functional outcomes and time to hospital
discharge were collected in all study patients.Aims
Patients and Methods
The primary aim of this study was to assess the rate of patient
satisfaction one year after total knee arthroplasty (TKA) according
to the focus of the question asked. The secondary aims were to identify
independent predictors of patient satisfaction according to the
focus of the question. A retrospective cohort of 2521 patients undergoing a primary
unilateral TKA were identified from an established regional arthroplasty
database. Patient demographics, comorbidities, Western Ontario and
McMaster Universities Osteoarthritis Index (WOMAC) and 12-Item Short-Form
Health Survey (SF-12) scores were collected preoperatively and one
year postoperatively. Patient satisfaction was assessed using four
questions, which focused on overall outcome, activity, work, and
pain. Logistic regression analysis was used to identify independent
preoperative predictors of increased stiffness when adjusting for
confounding variables.Aims
Patients and Methods
Oxidised zirconium was introduced as a material for femoral components
in total knee arthroplasty (TKA) as an attempt to reduce polyethylene
wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected
database to assess the ten year survival and clinical and radiological
outcomes of an oxidised zirconium total knee arthroplasty with the
Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis
Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS)
and a patient satisfaction scale were used to assess outcome.Aims
Methods
The aims of this retrospective study were to
compare the mid-term outcomes following revision total knee replacement
(TKR) in 76 patients (81 knees) <
55 years of age with those
of a matched group of primary TKRs based on age, BMI, gender and
comorbid conditions. We report the activity levels, functional scores,
rates of revision and complications. Compared with patients undergoing
primary TKR, those undergoing revision TKR had less improvement
in the mean Knee Society function scores (8.14 (–55 to +60) Young patients undergoing revision TKR should be counselled that
they can expect somewhat less improvement and a higher risk of complications
than occur after primary TKR. Cite this article:
Haematomas, drainage, and other non-infectious
wound complications following total knee replacement (TKR) have
been associated with long-term sequelae, in particular, deep infection.
However, the impact of these wound complications on clinical outcome
is unknown. This study compares results in 15 patients re-admitted
for wound complications within 90 days of TKR to 30 matched patients
who underwent uncomplicated total knee replacements. Patients with
wound complications had a mean age of 66 years (49 to 83) and mean
body mass index (BMI) of 37 (21 to 54), both similar to that of
patients without complications (mean age 65 years and mean BMI 35). Those
with complications had lower mean Knee Society function scores (46
(0 to 100 Cite this article:
We have shown in a previous study that patients with combined lesions of the anterior cruciate (ACL) and medial collateral ligaments (MCL) had similar anteroposterior (AP) but greater valgus laxity at 30° after reconstruction of the ACL when compared with patients who had undergone reconstruction of an isolated ACL injury. The present study investigated the same cohort of patients after a minimum of three years to evaluate whether the residual valgus laxity led to a poorer clinical outcome. Each patient had undergone an arthroscopic double-bundle ACL reconstruction using a semitendinosus-gracilis graft. In the combined ACL/MCL injury group, the grade II medial collateral ligament injury was not treated. At follow-up, AP laxity was measured using a KT-2000 arthrometer, while valgus laxity was evaluated with Telos valgus stress radiographs and compared with the uninjured knee. We evaluated clinical outcome scores, muscle girth and time to return to activities for the two groups. Valgus stress radiographs showed statistically significant greater mean medial joint opening in the reconstructed compared with the uninjured knees (1.7 mm (
We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time. At ten years after operation 238 patients (244 knees) remained for independent clinical and radiological assessment. There was a significant improvement (p <
0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% (95% CI 96 to 98) and survival using reoperation for any cause was 92% (95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees. There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score (p <
0.001). The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.