Advertisement for orthosearch.org.uk
Results 1 - 20 of 67
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1361 - 1366
1 Oct 2006
Moroz LA Launay F Kocher MS Newton PO Frick SL Sponseller PD Flynn JM

Between 1996 and 2003 six institutions in the United States and France contributed a consecutive series of 234 fractures of the femur in 229 children which were treated by titanium elastic nailing. Minor or major complications occurred in 80 fractures. Full information was available concerning 230 fractures, of which the outcome was excellent in 150 (65%), satisfactory in 57 (25%), and poor in 23 (10%). Poor outcomes were due to leg-length discrepancy in five fractures, unacceptable angulation in 17, and failure of fixation in one. There was a statistically significant relationship (p = 0.003) between age and outcome, and the odds ratio for poor outcome was 3.86 for children aged 11 years and older compared with those below this age. The difference between the weight of children with a poor outcome and those with an excellent or satisfactory outcome was statistically significant (54 kg vs 39 kg; p = 0.003). A poor outcome was five times more likely in children who weighed more than 49 kg


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1488 - 1494
1 Nov 2007
Gorodetskyi IG Gorodnichenko AI Tursin PS Reshetnyak VK Uskov ON

We undertook a trial on 60 patients with AO 31A2 fractures of the hip who were randomised after stabilisation of the fracture into two equal groups, one of which received post-operative treatment using a non-invasive interactive neurostimulation device and the other with a sham device. All other aspects of their rehabilitation were the same. The treatment was continued for ten days after operation.

Outcome measurements included the use of a visual analogue scale for pain, the brief pain inventory and Ketorolac for post-operative control of pain, and an overall assessment of outcome by the surgeon. There were significantly better results for the patients receiving treatment by active electrical stimulation (repeated measures analysis of variance, p < 0.001). The findings of this pilot trial justify a larger study to determine if these results are more generally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 23 - 29
1 Jan 2002
Vossinakis IC Badras LS

In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months.

Use of the PF was associated with significantly less blood loss, a shorter operating time, reduced postoperative pain, shorter hospitalisation (p < 0.001), earlier mobilisation (p < 0.001) and a reduced rate of mechanical complications (p < 0.01). Superficial infection was significantly more common with the PF (p < 0.01), but without long-term adverse consequences. There were no differences in the healing of the fracture, mortality or final functional outcome. Our results indicate that the external fixator is an effective and safe device for treating pertrochanteric fractures and should be considered as a useful alternative to conventional fixation with the sliding hip screw.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 77 - 79
1 Jan 1999
Weatherall M

In three consecutive years 462 patients over the age of 60 years presented at Waikato Hospital, Hamilton, New Zealand, with a fracture of the proximal femur. Within two years, 11 (2.4%) returned with a fracture of the contralateral femur. If the effectiveness of any form of treatment aiming at reducing the incidence of contralateral fracture were subjected to a trial, a sample size of 5000, randomly distributed equally between treatment and placebo groups, would be needed for the trial to have a power of 80% to detect a reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 393 - 398
1 Mar 2011
Findlay JM Keogh MJ Boulton C Forward DP Moran CG

We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in Clostridium difficile colitis (p = 0.017), deep wound infection (p = 0.043) and gastrointestinal haemorrhage (p = 0.033). There were no differences in any patient risk factors (except the prevalence of chronic obstructive pulmonary disease), cause of death and length of stay before and after intervention. The underlying mechanisms are unclear, but may include improved efficiency and medical contact time. These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 663 - 667
1 Jul 2001
Arazi M Memik R Ögün TC Yel M

Our aim was to determine the clinical effectiveness and safety of Ilizarov external fixation for the acute treatment of severely comminuted extra-articular and intercondylar fractures of the distal femur. A total of 14 consecutive patients with complex fractures was treated. There were three type-A3, two type-C2 and nine type-C3 fractures according to the AO/ASIF system. The mean follow-up was 14 months. Most fractures (13) united primarily at a mean of 16 weeks. One patient with a type-IIIA open fracture had infection and nonunion. The mean range of flexion of the knee at the final follow-up was 105° (35 to 130). We conclude that, in the treatment of comminuted fractures of the distal femur, the Ilizarov fixator is safe and effective in providing stability and allowing early rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 679 - 683
1 Jul 1998
Blundell CM Parker MJ Pryor GA Hopkinson-Woolley J Bhonsle SS

There are a number of classification systems for intracapsular fractures of the proximal femur, but none has been shown to be practical with satisfactory reproducibility and accurate predictive value. We have investigated the AO classification and evaluated intra-and interobserver accuracy and its value in predicting treatment and outcome. We found it to have very poor intra- and interobserver reliability and to be of limited predictive use for the outcome of treatment. A simplified system in which the subdivisions were allocated to one of three groups of undisplaced, displaced and basal fractures was found to be of value. We conclude that this is the only division which is appropriate for these fractures and that the AO system for intracapsular fractures is too complicated and should not be used


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 206 - 212
1 Mar 2001
Davison JNS Calder SJ Anderson GH Ward G Jagger C Harper WM Gregg PJ

We performed a prospective, randomised trial comparing three treatments for displaced intracapsular fractures of the hip in 280 patients aged 65 to 79 years.

The mean patient survival was significantly higher in the group undergoing reduction and internal fixation (79 months) compared with that with a cemented Thompson hemiarthroplasty or a cemented Monk bipolar hemiarthroplasty (61 months and 68 months, respectively). After three years, 32 of 93 patients (34.4%) who had undergone fixation had local complications, necessitating further intervention in 28 (30%). There were no significant differences in the functional outcome in survivors, who were reviewed annually to five years.

Either reduction and internal fixation or cemented hemiarthroplasty may be offered as alternative treatments for a displaced intracapsular fracture in a mobile and mentally competent patient under the age of 80 years. The choice of procedure by the patient and the surgeon should be determined by the realisation that the use of internal fixation is associated with a 30% risk of failure requiring further surgery. If this is accepted, however, hemiarthroplasty is avoided, which, in our study has a significantly shorter mean survival time. The use of a bipolar prosthesis has no significant advantage.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 840 - 845
1 Jun 2016
Chesser TJS Fox R Harding K Halliday R Barnfield S Willett K Lamb S Yau C Javaid MK Gray AC Young J Taylor H Shah K Greenwood R

Aims

We wished to assess the feasibility of a future randomised controlled trial of parathyroid hormone (PTH) supplements to aid healing of trochanteric fractures of the hip, by an open label prospective feasibility and pilot study with a nested qualitative sub study. This aimed to inform the design of a future powered study comparing the functional recovery after trochanteric hip fracture in patients undergoing standard care, versus those who undergo administration of subcutaneous injection of PTH for six weeks.

Patients and Methods

We undertook a pilot study comparing the functional recovery after trochanteric hip fracture in patients 60 years or older, admitted with a trochanteric hip fracture, and potentially eligible to be randomised to either standard care or the administration of subcutaneous PTH for six weeks. Our desired outcomes were functional testing and measures to assess the feasibility and acceptability of the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1123 - 1126
1 Aug 2005
Siegmeth AW Gurusamy K Parker MJ

Previous studies on the timing of surgery for fracture of the hip provide conflicting evidence as to the effect of prolonged delay before operation. We have prospectively reviewed 3628 such fractures in patients older than 60 years of age. Those for whom the delay was for medical reasons were excluded. Patients were followed up for one year or until death. Operation was undertaken within 48 hours in 95.2% and after this in 4.8%. A significant increase in length of stay was found in patients operated on after 48 hours when compared with those in the earlier group (21.6 vs 32.5 days). No increase in hospital stay was found for lesser delays.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 769 - 774
1 Apr 2021
Hoogervorst LA Hart MJ Simpson PM Kimmel LA Oppy A Edwards ER Gabbe BJ

Aims. Complex fractures of the femur and tibia with associated severe soft tissue injury are often devastating for the individual. The aim of this study was to describe the two-year patient-reported outcomes of patients in a civilian population who sustained a complex fracture of the femur or tibia with a Mangled Extremity Severity Score (MESS) of ≥ 7, whereby the score ranges from 2 (lowest severity) to 11 (highest severity). Methods. Patients aged ≥ 16 years with a fractured femur or tibia and a MESS of ≥ 7 were extracted from the Victorian Orthopaedic Trauma Outcomes Registry (January 2007 to December 2018). Cases were grouped into surgical amputation or limb salvage. Descriptive analysis were used to examine return to work rates, three-level EuroQol five-dimension questionnaire (EQ-5D-3L), and Glasgow Outcome Scale-Extended (GOS-E) outcomes at 12 and 24 months post-injury. Results. In all, 111 patients were included: 90 (81%) patients who underwent salvage and 21 (19%) patients with surgical amputation. The mean age of patients was 45.8 years (SD 15.8), 93 (84%) were male, 37 (33%) were involved in motor vehicle collisions, and the mean MESS score was 8.2 (SD 1.4). Two-year outcomes in the cohort were poor: six (7%) patients achieved a GOS-E good recovery, the mean EQ-5D-3L summary score was 0.52 (SD 0.27), and 17 (20%) patients had returned to work. Conclusion. A small proportion of patients with severe lower limb injury (MESS ≥ 7) achieved a good level of function 24 months post-injury. Further follow-up is needed to better understand the long-term trajectory of these patients, including delayed amputation, hospital readmissions, and healthcare utilization. Cite this article: Bone Joint J 2021;103-B(4):769–774


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 842 - 846
1 Jun 2015
Bennett PM Sargeant ID Myatt RW Penn-Barwell JG

This is a retrospective study of survivors of recent conflicts with an open fracture of the femur. We analysed the records of 48 patients (48 fractures) and assessed the outcome. The median follow up for 47 patients (98%) was 37 months (interquartile range 19 to 53); 31 (66%) achieved union; 16 (34%) had a revision procedure, two of which were transfemoral amputation (4%). The New Injury Severity Score, the method of fixation, infection and the requirement for soft-tissue cover were not associated with a poor outcome. The degree of bone loss was strongly associated with a poor outcome (p = 0.00204). A total of four patients developed an infection; two with S. aureus, one with E. coli and one with A. baumannii. This study shows that, compared with historical experience, outcomes after open fractures of the femur sustained on the battlefield are good, with no mortality and low rates of infection and late amputation. The degree of bone loss is closely associated with a poor outcome. Cite this article: Bone Joint J 2015;97-B:842–6


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral femoral bowing angles were 10.5° (SD 5.7°)/6.1° (SD 6.2°). The postoperative mean anterior/lateral bowing values were changed by 8.7° (SD 5.4°)/4.6° (SD 5.9°). Bisphosphonates had been used contemporarily in 115 AFFs (78.2%) for a mean of 52.4 months (1 to 204; SD 45.5) preoperatively. Nailing was performed in 133 AFFs (90.5%), and union was obtained at a mean of 23.6 weeks (7 to 85). Delayed union occurred in 41 (27.9%), and nonunion occurred in 13 (8.8%). Contralateral AFF occurred in 79 patients (53.7%), and the use of a bisphosphonate significantly influenced the occurrence of contralateral AFFs (p = 0.019). Peri-implant fractures occurred in a total of 13 patients (8.8%), and a significant increase was observed in cases with plating (p = 0.021) and high grade of postoperative anterolateral bowing (p = 0.044). Conclusion. The use of a bisphosphonate was found to be a risk factor for contralateral AFF, and high-grade postoperative anterolateral bowing and plate fixation significantly increased the occurrence of peri-implant fractures. Long-term follow-up studies on the bilaterality of AFFs and peri-implant fractures are warranted. Cite this article: Bone Joint J 2021;103-B(11):1648–1655


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 972 - 979
1 Aug 2022
Richardson C Bretherton CP Raza M Zargaran A Eardley WGP Trompeter AJ

Aims

The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland.

Methods

The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily living”.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 686 - 689
1 May 2016
Griffin XL Parsons N McArthur J Achten J Costa ML

Aims. The aim of this study was to inform a definitive trial which could determine the clinical effectiveness of the X-Bolt Dynamic Hip Plating System compared with the sliding hip screw for patients with complex pertrochanteric fragility fractures of the femur. Patients and Methods. This was a single centre, participant blinded, randomised, standard-of-care controlled pilot trial. Patients aged 60 years and over with AO/ASIF A2 and A3 type femoral pertrochanteric fractures were eligible. Results. The primary outcome was the EuroQoL 5 Dimension Score (EQ-5D-3L) at one year following index fixation. A total of 100 participants were recruited, and primary outcome data were available for 88 patients following losses to follow-up and withdrawals. The mean difference in EQ-5D was 0.03 (95% confidence interval -0.17, 0.120; p = 0.720.) There were no significant differences in any of the secondary outcomes measures. The recruitment and follow-up rates from this feasibility study were as predicted. Conclusion. A definitive trial with 90% power to find a clinically important difference in EQ-5D would require 964 participants based upon the data from this study. We plan to start recruitment to this trial in Spring 2016. Take home message: A definitive trial of X-Bolt Dynamic Hip Plating System is feasible and should be conducted now in order to quantify the clinical effectiveness of this novel implant. Cite this article: Bone Joint J 2016;98-B:686–9


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 142 - 149
1 Jan 2022
Armstrong BRW Devendra A Pokale S Subramani B Rajesh Babu V Ramesh P Dheenadhayalan J Rajasekaran S

Aims

The aim of this study was to assess whether it is possible to predict the mortality, and the extent and time of neurological recovery from the time of the onset of symptoms and MRI grade, in patients with the cerebral fat embolism syndrome (CFES). This has not previously been investigated.

Methods

The study included 34 patients who were diagnosed with CFES following trauma between 2012 and 2018. The clinical diagnosis was confirmed and the severity graded by MRI. We investigated the rate of mortality, the time and extent of neurological recovery, the time between the injury and the onset of symptoms, the clinical severity of the condition, and the MRI grade. All patients were male with a mean age of 29.7 years (18 to 70). The mean follow-up was 4.15 years (2 to 8), with neurological recovery being assessed by the Glasgow Outcome Scale and the Mini-Mental State Examination.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 967 - 971
1 Sep 2000
Patton JT Cook RE Adams CI Robinson CM

In a consecutive series of 498 patients with 528 fractures of the femur treated by conventional interlocking intramedullary nailing, 14 fractures of the femoral neck (2.7%) occurred in 13 patients. The fracture of the hip was not apparent either before operation or on the immediate postoperative radiographs. It was diagnosed in the first two weeks after operation in three patients and after three months in the remainder. Age over 60 years at the time of the femoral fracture and female gender were significantly predictive of hip fracture on bivariate logistic regression analysis, but on multivariate analysis only the location of the original fracture in the proximal third of the femur (p = 0.0022, odds ratio = 6.96, 95% CI 2.01 to 24.14), low-energy transfer (p = 0.0264, odds ratio = 15.56, 95% CI 1.38 to 75.48) and the severity of osteopenia on radiographs (p = 0.0128, odds ratio = 7.55, 95% CI 1.54 to 37.07) were significant independent predictors of later fracture. Five of the 19 women aged over 60 years, who sustained an osteoporotic proximal diaphyseal fracture of the femur during a simple fall, subsequently developed a fracture of the neck. Eleven of the hip fractures were displaced and intracapsular and, in view of the advanced age of most of these patients, were usually treated by replacement arthroplasty. Reduction and internal fixation was used to treat the remaining three intertrochanteric fractures. Three patients developed complications requiring further surgery; five died within two years of their fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 97 - 101
1 Jan 2009
Clasper JC Rowley DI

We reviewed the clinical details and radiographs of 52 patients with ballistic fractures of the femur admitted to the International Committee of the Red Cross Hospital in Kenya (Lopiding), who had sustained injuries in neighbouring Sudan. In all cases there had been a significant delay in the initial surgery (> 24 hours), and all patients were managed without stabilisation of the fracture by internal or external fixation. Of the 52 patients, three required an amputation for persisting infection of the fracture site despite multiple debridements. A further patient was treated by an excision arthroplasty of the hip, but this was carried out at the initial operation as a part of the required debridement. All of the remaining 48 fractures healed. Four patients needed permanent shoe adaptation because of limb shortening of functional significance. Although we do not advocate delaying treatment or using traction instead of internal or external fixation, we have demonstrated that open femoral fractures can heal despite limited resources