Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1597 - 1601
1 Dec 2008
Thompson NW Kapoor A Thomas J Hayton MJ

We describe the use of a vascularised periosteal patch onlay graft based on the 1,2 intercompartmental supraretinacular artery in the management of 11 patients (ten men, one woman) with chronic nonunion involving the proximal third of the scaphoid. The mean age of the patients was 31 years (21 to 45) with the dominant hand affected in eight. Six of the patients were smokers and three had undergone previous surgery to the scaphoid. All of the proximal fragments were avascular. The presence of union was assessed using longitudinal axis CT.

Only three patients progressed to union of the scaphoid and four required a salvage operation for a symptomatic nonunion. The remaining four patients with a persistent nonunion are asymptomatic with low pain scores, good grip strength and a functional range of wrist movement.

Although this technique has potential technical advantages over vascularised pedicled bone grafting, the rate of union has been disappointing and we do not recommend it as a method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty.

Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications.