Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries. This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation.Aims
Methods
We performed ulnar nerve neurolysis and transposition during reconstructive operations on 20 consecutive patients (21 elbows) with neuropathy after the failure of primary treatment of
The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size. This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.Aims
Methods
Patient engagement in adaptive health behaviours and interactions with their healthcare ecosystem can be measured using self-reported instruments, such as the Patient Activation Measure (PAM-13) and the Effective Consumer Scale (ECS-17). Few studies have investigated the influence of patient engagement on limitations (patient-reported outcome measures (PROMs)) and patient-reported experience measures (PREMs). First, we assessed whether patient engagement (PAM-13, ECS-17) within two to four weeks of an upper limb fracture was associated with limitations (the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), and Patient-Reported Outcome Measurement Information System Upper Extremity Physical Function computer adaptive test (PROMIS UE PF) scores) measured six to nine months after fracture, accounting for demographic, clinical, and psychosocial factors. Secondly, we assessed the association between patient engagement and experience (numerical rating scale for satisfaction with care (NRS-C) and satisfaction with services (NRS-S) six to nine months after fracture. A total of 744 adults with an isolated fracture of the proximal humerus, elbow, or distal radius completed PROMs. Due to multicollinearity of patient engagement and psychosocial variables, we generated a single variable combining measures of engagement and psychosocial factors using factor analysis. We then performed multivariable analysis with p < 0.10 on bivariate analysis.Aims
Methods
Outcome measures quantifying aspects of health in a precise,
efficient, and user-friendly manner are in demand. Computer adaptive
tests (CATs) may overcome the limitations of established fixed scales
and be more adept at measuring outcomes in trauma. The primary objective
of this review was to gain a comprehensive understanding of the
psychometric properties of CATs compared with fixed-length scales
in the assessment of outcome in patients who have suffered trauma
of the upper limb. Study designs, outcome measures and methodological
quality are defined, along with trends in investigation. A search of multiple electronic databases was undertaken on 1
January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”,
and “anatomical regions”. Studies involving adults suffering trauma
to the upper limb, and undergoing any intervention, were eligible.
Those involving the measurement of outcome with any CATs were included.
Identification, screening, and eligibility were undertaken, followed
by the extraction of data and quality assessment using the Consensus-Based
Standards for the Selection of Health Measurement Instruments (COSMIN) criteria.
The review is reported according to the Preferred Reporting Items
for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg istered (PROSPERO: CRD42016053886).Aims
Materials and Methods
Fracture clinics are often characterised by the referral of large
numbers of unselected patients with minor injuries not requiring
investigation or intervention, long waiting times and recurrent
unnecessary reviews. Our experience had been of an unsustainable
system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order
to rationalise and regulate access to our fracture service. The
British Orthopaedic Association’s guidelines have required a prospective evaluation
of this change of practice, and we report our experience and results. We review the management of all 12 069 patients referred to our
service in the calendar year 2014, with a minimum of one year follow-up
during the calendar year 2015. Aims
Patients and Methods
A total of 14 women and seven men with a mean age of 43 years (18 to 68) who sustained a Mason type IV fracture of the elbow, without an additional type II or III coronoid fracture, were evaluated after a mean of 21 years (14 to 46). Primary treatment included closed elbow reduction followed by immobilisation in a plaster in all cases, with an additional excision of the radial head in 11, partial resection in two and suturing of the annular ligament in two. Delayed radial head excision was performed in two patients and an ulnar nerve transposition in one. The uninjured elbows served as controls. Nine patients had no symptoms, 11 reported slight impairment, and one severe impairment of the elbow. Elbow flexion was impaired by a mean of 3° ( We conclude that most patients with a Mason type IV fracture of the elbow report a good long-term outcome.
In order to achieve satisfactory reduction of
complex distal humeral fractures, adequate exposure of the fracture fragments
and the joint surface is required. Several surgical exposures have
been described for distal humeral fractures. We report our experience
using the anconeus pedicle olecranon flip osteotomy approach. This
involves detachment of the triceps along with a sliver of olecranon,
which retains the anconeus pedicle. We report the use of this approach
in ten patients (six male, four female) with a mean age of 38.4
years (28 to 51). The mean follow-up was 15 months (12 to 18) with
no loss to follow-up. Elbow function was graded using the Mayo Score.
The results were excellent in four patients, good in five and fair
in one patient. The mean time to both fracture and osteotomy union
was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We
found this approach gave reliably good exposure for these difficult
fractures enabling anatomical reduction and bicondylar plating without
complications. Cite this article:
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
We have reviewed 20 women and three men aged 22 to 73 years, who had sustained a Mason type-IIb fracture of the neck of the radius 14 to 25 years earlier. There were 19 patients with displacement of the fractures of 2 mm to 4 mm, of whom 13 had been subjected to early mobilisation and six had been treated in plaster for one to four weeks. Of four patients with displacement of 4 mm to 8 mm, three had undergone excision and one an open reduction of the head of radius. A total of 21 patients had no subjective complaints at follow-up, but two had slight impairment and occasional elbow pain. The mean range of movement and strength of the elbow were not impaired. The elbows had a higher prevalence of degenerative changes than the opposite side, but no greater reduction of joint space. Mason type-IIb fractures have an excellent long-term outcome if operation is undertaken when the displacement of the fracture exceeds 4 mm.