Patient warming significantly decreases the risk
of surgical site infection. Recently there have been concerns that forced
air warming may interfere with unidirectional airflow, potentially
posing an increased risk of infection. Our null hypothesis was that
forced air and radiant warming
Aims. The purpose of this current multicentre study is to analyse the
presence of alpha-defensin proteins in synovial fluid using the
Synovasure lateral flow
Aims. The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer. Materials and Methods. Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed. Results. In 104 implants, a decrease in the odds of loosening and an increase in metallosis and tissue staining in the Duofix group relative to Porocoat group was detected (p = 0.028). There was an increased presence of embedded metallic debris in the Duofix group (p < 0.001). Decreased tissue ingrowth was associated with the Duofix surface (p < 0.001). The attached beads had reduced microhardness, indicative of adverse thermal processing, which resulted in bead shedding, particulate debris, and metallosis. Conclusion. Hydroxyapatite coating of the LCS femoral component produced unexpected results and led to its recall. The root cause was likely a combination of retained alumina grit and a reduction in bead microhardness (mechanical strength) resulting in increased particle debris, metallosis, and early revision. The Duofix LCS femoral component was not equivalent to the Porocoat version despite its approval through the Food and Drug Administration (FDA) 510(k) equivalance approval process. Regulation of the introduction of modified existing
A higher failure rate has been reported in haematogenous periprosthetic joint infection (PJI) compared to non-haematogenous PJI. The reason for this difference is unknown. We investigated the outcome of haematogenous and non-haematogenous PJI to analyze the risk factors for failure in both groups of patients. Episodes of knee or hip PJI (defined by the European Bone and Joint Infection Society criteria) treated at our institution between January 2015 and October 2020 were included in a retrospective PJI cohort. Episodes with a follow-up of > one year were stratified by route of infection into haematogenous and non-haematogenous PJI. Probability of failure-free survival was estimated using the Kaplan-Meier method, and compared between groups using log-rank test. Univariate and multivariate analysis was applied to assess risk factors for failure.Aims
Methods
Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy.Aims
Methods
Routinely collected patient-reported outcome measures (PROMs) have been useful to quantify and quality-assess provision of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the UK for the past decade. This study aimed to explore whether the outcome following primary THA and TKA had improved over the past seven years. Secondary data analysis of 277,430 primary THAs and 308,007 primary TKAs from the NHS PROMs programme was undertaken. Outcome measures were: postoperative Oxford Hip/Knee Score (OHS/OKS); proportion of patients achieving a clinically important improvement in joint function (responders); quality of life; patient satisfaction; perceived success; and complication rates. Outcome measures were compared based on year of surgery using multiple linear and logistic regression models.Aims
Methods
We have recently shown that waste heat from forced-air
warming blankets can increase the temperature and concentration
of airborne particles over the surgical site. The mechanism for
the increased concentration of particles and their site of origin
remained unclear. We therefore attempted to visualise the airflow
in theatre over a simulated total knee replacement using neutral-buoyancy
helium bubbles. Particles were created using a Rocket PS23 smoke
machine positioned below the operating table, a potential area of
contamination. The same theatre set-up, warming
Currently, the US Center for Medicaid and Medicare Services (CMS) has been testing bundled payments for revision total joint arthroplasty (TJA) through the Bundled Payment for Care Improvement (BPCI) programme. Under the BPCI, bundled payments for revision TJAs are defined on the basis of diagnosis-related groups (DRGs). However, these DRG-based bundled payment models may not be adequate to account appropriately for the varying case-complexity seen in revision TJAs. The 2008-2014 Medicare 5% Standard Analytical Files (SAF5) were used to identify patients undergoing revision TJA under DRG codes 466, 467, or 468. Generalized linear regression models were built to assess the independent marginal cost-impact of patient, procedural, and geographic characteristics on 90-day costs.Aims
Methods
Obtaining a balanced flexion gap with correct
femoral component rotation is one of the prerequisites for a successful
outcome after total knee replacement (TKR). Different techniques
for achieving this have been described. In this study we prospectively
compared gap-balancing versus measured resection
in terms of reliability and accuracy for femoral component rotation
in 96 primary TKRs performed in 96 patients using the Journey system.
In 48 patients (18 men and 30 women) with a mean age of 65 years
(45 to 85) a tensor
The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check. Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).Aims
Materials and Methods
We have assessed the effect of a variety of implants commonly used in fracture fixation and joint replacement on the activation of metal detectors at airport security gates. A volunteer with metal implants strapped on and patients with implants in situ walked through the
The purpose of this study was to assess early physical function
after total hip or knee arthroplasty (THA/TKA), and the correlation
between patient-reported outcome measures, physical performance
and actual physical activity (measured by actigraphy). A total of 80 patients aged 55 to 80 years undergoing THA or
TKA for osteoarthritis were included in this prospective cohort
study. The main outcome measure was change in patient reported hip
or knee injury and osteoarthritis outcome score (HOOS/KOOS) from
pre-operatively until post-operative day 13 (THA) or 20 (TKA). Secondary measures
were correlations to objectively assessed change in physical performance
(paced-walk, chair-stand, stair-climb tests) at day 14 (THA) or
21 (TKA) and actual physical activity (actigraphy) measured at day
12 and 13 (THA) or 19 and 20 (TKA). Aims
Patients and Methods
The interaction between surgical lighting and laminar airflow
is poorly understood. We undertook an experiment to identify any
effect contemporary surgical lights have on laminar flow and recommend
practical strategies to limit any negative effects. Neutrally buoyant bubbles were introduced into the surgical field
of a simulated setup for a routine total knee arthroplasty in a
laminar flow theatre. Patterns of airflow were observed and the
number of bubbles remaining above the surgical field over time identified.
Five different lighting configurations were assessed. Data were analysed
using simple linear regression after logarithmic transformation.Aims
Materials and Methods
Positive cultures are not uncommon in cases of revision total
knee and hip arthroplasty (TKA and THA) for presumed aseptic causes.
The purpose of this study was to assess the incidence of positive
intra-operative cultures in presumed aseptic revision of TKA and
THA, and to determine whether the presence of intra-operative positive cultures
results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients
undergoing revision knee (340 cases) or hip arthroplasty (339 cases)
for presumed aseptic causes. For all patients three or more separate
intra-operative cultures were obtained. Patients were diagnosed
with a previously unsuspected prosthetic joint infection (PJI) if two
or more cultures were positive with the same organism. Records were
reviewed for demographic details, pre-operative laboratory results
and culture results. The primary outcome measure was infection-free
implant survival at two years.Aims
Patients and Methods
The aim of this study was to present data on 11 459 patients
who underwent total hip (THA), total knee (TKA) or unicompartmental
knee arthroplasty (UKA) between November 2002 and April 2014 with
aspirin as the primary agent for pharmacological thromboprophylaxis. We analysed the incidence of deep vein thrombosis (DVT) and pulmonary
embolism (PE) then compared the 90-day all-cause mortality with
the corresponding data in the National Joint Registry for England
and Wales (NJR). Aims
Patients and Methods
During the last ten years, greater attention
has been given to the management of peri-operative blood loss after
total knee arthroplasty (TKA), as it is a modifiable outcome that has
a significant effect on the rate of complications, the recovery,
and the economic burden. Blood loss after TKA has been greatly reduced
during this time, thereby dramatically reducing the rates of allogeneic
transfusion. This has significantly reduced the complications associated
with transfusion, such as fluid overload, infection, and increased length
of stay. The greatest advent in lowering peri-operative blood loss after
TKA has been the introduction of tranexamic acid, which reduces
blood loss without increasing the risk of thromboembolic events. This paper discusses the ways of reducing blood loss after TKA,
for which a multimodal algorithm, with pre-, intra- and post-operative
measures, has been adopted at our institution. Cite this article:
Total joint arthroplasty (TJA) is commonly performed in elderly
patients. Frailty, an aggregate expression of vulnerability, becomes
increasingly common with advanced age, and independently predicts
adverse outcomes and the use of resources after a variety of non-cardiac
surgical procedures. Our aim was to assess the impact of frailty
on outcomes after TJA. We analysed the impact of pre-operative frailty on death and
the use of resources after elective TJA in a population-based cohort
study using linked administrative data from Ontario, Canada.Aims
Patients and Methods
There is evidence that high levels of physical
activity following arthroplasty of the hip or knee can lead to early revision.
However, the term ‘highly active’ is not well defined. A validated ankle accelerometer was used to quantify activity
in 13 patients, who had undergone a total of 20 arthroplasties of
the lower limbs and who had active lifestyles. The assessments were
taken at a mean of 8.7 years post-operatively (1.8 to 15.8). The mean gait cycles per day was 8273 (5964 to 12 557), which
extrapolates to 3.0 million cycles per year (cpy) (2.2 to 4.6).
The mean percentage of time spent in high activity mode was 4.3%,
or about one hour per day. The mean percentage of cycles in high
activity was 40%. Based on these data, we propose the following definitions of
high activity: >
3 million cpy; one hour per day in high activity
mode; 40% of cycles in high activity mode. Extrapolating the sample of activity over the time since operation,
the mean cycles per arthroplasty was 25.2 million, with a maximum
of 44.1 million. No joint has been revised, or shows evidence of
impending failure. Cite this article:
We hypothesised there was no clinical value in
using an autologous blood transfusion (ABT) drain in either primary total
hip (THR) or total knee replacement (TKR) in terms of limiting allogeneic
blood transfusions when a modern restrictive blood management regime
was followed. A total of 575 patients (65.2% men), with a mean age
of 68.9 years (36 to 94) were randomised in this three-arm study
to no drainage (group A), or to wound drainage with an ABT drain
for either six hours (group B) or 24 hours (group C). The primary
outcome was the number of patients receiving allogeneic blood transfusion.
Secondary outcomes were post-operative haemoglobin (Hb) levels,
length of hospital stay and adverse events. This study identified only 41 transfused patients, with no significant
difference in distribution between the three groups (p = 0.857).
The mean pre-operative haemoglobin (Hb) value in the transfused
group was 12.8 g/dL (9.8 to 15.5) Cite this article:
The purpose of this study was to compare the
diagnostic accuracy for the detection of infection between the culture of
fluid obtained by sonication (SFC) and the culture of peri-implant
tissues (PITC) in patients with early and delayed implant failure,
and those with unsuspected and suspected septic failure. It was
hypothesised that SFC increases the diagnostic accuracy for infection
in delayed, but not early, implant failure, and in unsuspected septic
failure. The diagnostic accuracy for infection of all consecutive
implants (hardware or prostheses) that were removed for failure was
compared between SFC and PITC. This prospective study included 317
patients with a mean age of 62.7 years (9 to 97). The sensitivity
for detection of infection using SFC was higher than using PITC
in an overall comparison (89.9% Sonication is mainly recommended when there is implant failure
with no clear signs of infection and in patients with delayed implant
failure. In early failure, SFC is not superior to PITC for the diagnosis
of infection and, therefore, is not recommended as a routine diagnostic
test in these patients. Cite this article: