Advertisement for orthosearch.org.uk
Results 1 - 20 of 307
Results per page:

Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. Methods. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype. Results. The most common phenotype was Type I-b (mild to moderate varus alignment-medial joint line; 27.1% (n = 256)), followed by Type IV-b (23.2%; n = 219). There was no significant difference in the clinical outcomes and long-term survival between the groups. In Type IV-b phenotypes, the neutrally corrected group showed higher 15-year survival compared with the unchanged-phenotype group (94.9% (95% confidence interval (CI) 92.0 to 97.8) vs 74.2% (95% CI 98.0 to 100); p = 0.020). Conclusion. Constitutional varus was confirmed in more than half of these patients. Mechanically aligned TKA can achieve consistent clinical outcomes and long-term survival, regardless of the patient’s phenotype. The neutrally corrected group had better long-term survival compared with the unchanged phenotype group. Cite this article: Bone Joint J 2024;106-B(5):460–467


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims. The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique. Methods. This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCA. PD. ), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves. Results. Patients in whom the medial joint opening was achieved had significantly better postoperative PROMs compared with those without medial opening (all p < 0.05). Patients who were outliers with deviation of > 10% from the target mechanical axis deviation had significantly similar PROMs compared with patients with an acceptable axis deviation (all p > 0.05). Medial joint opening was affected by postoperative mechanical axis deviation and JLCA. PD. The influence of JLCA. PD. on postoperative axis deviation was more pronounced in a closing wedge than in an opening wedge HTO. Conclusion. Medial joint opening rather than the mechanical axis deviation determined the clinical outcome in patients who underwent HTO. The JLCA. PD. identified the optimal postoperative axis deviation necessary to achieve medial joint opening. For patients with increased laxity, lowering the target axis deviation is recommended to achieve medial joint opening. The target axis deviation should also differ according to the technique of undergoing HTO. Cite this article: Bone Joint J 2024;106-B(3):240–248


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims. Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. Methods. The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups. Results. Overall, 104 (80%) patients of the original 130 who received surgery were available at five years (55 robotic, 49 manual). Both procedures reported successful results over all outcomes. At five years, there were no statistical differences between the groups in any of the patient reported or clinical outcomes. There was a lower reintervention rate in the robotic arm-assisted group with 0% requiring further surgery compared with six (9%) of the manual group requiring additional surgical intervention (p < 0.001). Conclusion. This study has shown excellent clinical outcomes in both groups with no statistical or clinical differences in the patient-reported outcome measures. The notable difference was the lower reintervention rate at five years for roboticarm-assisted UKA when compared with a manual approach. Cite this article: Bone Joint J 2021;103-B(6):1088–1095


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 604 - 612
1 May 2022
MacDessi SJ Wood JA Diwan A Harris IA

Aims. Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA. Methods. A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS. 4. ) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures. Results. There was no significant difference in ΔKOOS. 4. between the two groups at two years (mean difference 0.4 points (95% confidence interval (CI) -4.6 to 5.4); p = 0.869), and multiple regression found that SB was not associated with a significant ΔKOOS. 4. (0.2-point increase (95% CI -5.1 to 4.6); p = 0.924). There were no significant differences between groups in other PROMs. Six-minute walking distance was significantly increased in the SB group (mean difference 29 metres; p = 0.015). Four-times as many TKAs were unbalanced in the MB group (36.8% MB vs 9.4% SB; p < 0.001). Irrespective of group assignment, no differences were found in any PROM when increasing ICPD thresholds defined balance. Conclusion. Despite improved quantitative soft-tissue balance, the use of sensors intraoperatively did not differentially improve the clinical or functional outcomes two years after TKA. These results question whether a more precisely balanced TKA that is guided by sensor data, and often achieved by more balancing interventions, will ultimately have a significant effect on clinical outcomes. Cite this article: Bone Joint J 2022;104-B(5):604–612


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 660 - 666
1 Jun 2019
Chalmers BP Limberg AK Athey AG Perry KI Pagnano MW Abdel MP

Aims. There is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome. Patients and Methods. We retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m. 2. (20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem. Results. The ten-year survivorship was 95% with aseptic loosening as the endpoint, 88% with revision for any reason as the endpoint, and 81% with re-operation for any reason as the endpoint. Three TKAs were revised for instability (n = 2) and aseptic tibial loosening (n = 1). No femoral component was revised for aseptic loosening. Patients under the age of 50 years were at greater risk of revision for any reason (hazard ratio 7; p = 0.03). There were two additional re-operations (6%) and four complications (13%), including three manipulations under anaesthetic (MUA; 10%). The Knee Society scores improved from a mean of 50 preoperatively (32 to 68) to a mean of 93 postoperatively (76 to 100; p < 0.001). Conclusion. A cemented posterior-stabilized TKA has an 88% ten-year survivorship with revision for any reason as the endpoint. No femoral component was revised for aseptic loosening. Patients under the age of 50 years have a greater risk of revision. The clinical outcome was significantly improved but balancing the knee was challenging in 13% of TKAs requiring VVC. Overall, 10% of TKAs needed an MUA, and 6% of TKAs were revised for instability. Cite this article: Bone Joint J 2019;101-B:660–666


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 435 - 442
1 Apr 2019
Zambianchi F Franceschi G Rivi E Banchelli F Marcovigi A Nardacchione R Ensini A Catani F

Aims. The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA). Patients and Methods. Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as “good” and “bad” if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded. Results. Following exclusions and losses to follow-up, 334 medial robotic-arm assisted UKAs were assessed at a mean follow-up of 30.0 months (8.0 to 54.9). None of the measured parameters were associated with overall KOOS outcome. Correlations were described between specific KOOS subscales and intraoperative, post-implantation robotic data, and between FJS-12 and femoral component sagittal alignment. Three UKAs were revised, resulting in 99.0% survival at two years (95% confidence interval (CI) 97.9 to 100.0). Conclusion. Although little correlation was found between intraoperative robotic data and overall clinical outcome, surgeons should consider information regarding 3D component placement and soft-tissue balancing to improve patient satisfaction. Reproducible and precise placement of components has been confirmed as essential for satisfactory clinical outcome. Cite this article: Bone Joint J 2019;101-B:435–442


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims. The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA). Patients and Methods. We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m. 2. were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m. 2. were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed. Results. Patients in the obese group underwent UKA at a significantly younger mean age (56.5 years (. sd. 6.4)) than those in the control group (62.4 years (. sd. 7.8); p < 0.001). There was no significant difference in preoperative functional scores. However, those in the obese group had a significantly lower ROM (116° (. sd. 15°) vs 123° (. sd. 17°); p = 0.003). Both groups achieved significant improvement in outcome scores regardless of BMI, ten years postoperatively. All patients achieved the minimal clinically important difference (MCID) for OKS and KSS. Both groups also had high rates of satisfaction (96.3% in the control group and 97.5% in the obese group) and the fulfilment of expectations (94.9% in the control group and 95.0% in the obese group). Multiple linear regression showed a clear association between obesity and a lower OKS two years postoperatively and Knee Society Function Score (KSFS) ten years postoperatively. After applying propensity matching, obese patients had a significantly lower KSFS, OKS, and physical component score (PCS) ten years postoperatively. Seven patients underwent revision to total knee arthroplasty (TKA), two in the control group and five in the obese group, resulting in a mean rate of survival at ten years of 98.6% and 88.1%, respectively (p = 0.012). Conclusion. Both groups had significant improvements in functional and quality-of-life scores postoperatively. However, obesity was a significant predictor of poorer improvement in clinical outcome and an increased rate of revision ten years postoperatively


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 737 - 742
1 Jun 2014
Eggerding V van Kuijk KSR van Meer BL Bierma-Zeinstra SMA van Arkel ERA Reijman M Waarsing JH Meuffels DE

We have investigated whether shape of the knee can predict the clinical outcome of patients after an anterior cruciate ligament rupture. We used statistical shape modelling to measure the shape of the knee joint of 182 prospectively followed patients on lateral and Rosenberg view radiographs of the knee after a rupture of the anterior cruciate ligament. Subsequently, we associated knee shape with the International Knee Documentation Committee subjective score at two years follow-up. The mean age of patients was 31 years (21 to 51), the majority were male (n = 121) and treated operatively (n = 135). We found two modes (shape variations) that were significantly associated with the subjective score at two years: one for the operatively treated group (p = 0.002) and one for the non-operatively treated group (p = 0.003). Operatively treated patients who had higher subjective scores had a smaller intercondylar notch and a smaller width of the intercondylar eminence. Non-operatively treated patients who scored higher on the subjective score had a more pyramidal intercondylar notch as opposed to one that was more dome-shaped. We conclude that the shape of the femoral notch and the intercondylar eminence is predictive of clinical outcome two years after a rupture of the anterior cruciate ligament. Cite this article: Bone Joint J 2014;96-B:737–42


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 604 - 608
1 May 2007
Park KK Chang CB Kang YG Seong SC Kim TK

This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year postoperatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1° (60° to 160°) to 133.0° (105° to 150°). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120°, we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9 vs 47.3, p = 0.031). Knees with a maximum flexion of more than 135° had a better functional Western Ontario McMasters Universities Osteoarthritis index score than knees with maximum flexion of 135° or less (17.5 vs 14.3, p = 0.031). We found only weak correlation between the postoperative maximum flexion and the clinical parameters for pain relief, function and quality of life, even in Korean patients. Efforts to increase post-operative maximum flexion should be exercised with caution until concerns relating to high-flexion activities are sufficiently resolved


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1325 - 1332
1 Oct 2014
Nakamae A Ochi M Deie M Adachi N Shibuya H Ohkawa S Hirata K

We report the clinical outcome and findings at second-look arthroscopy of 216 patients (mean age 25 years (11 to 58)) who underwent anterior cruciate ligament (ACL) reconstruction or augmentation. There were 73 single-bundle ACL augmentations (44 female, 29 male), 82 double-bundle ACL reconstructions (35 female, 47 male), and 61 single-bundle ACL reconstructions (34 female, 27 male). In 94 of the 216 patients, proprioceptive function of the knee was evaluated before and 12 months after surgery using the threshold to detect passive motion test. Second-look arthroscopy showed significantly better synovial coverage of the graft in the augmentation group (good: 60 (82%), fair: 10 (14%), poor: 3 (4%)) than in the other groups (p = 0.039). The mean side-to-side difference measured with a KT-2000 arthrometer was 0.4 mm (-3.3 to 2.9) in the augmentation group, 0.9 mm (-3.2 to 3.5) in the double-bundle group, and 1.3 mm (-2.7 to 3.9) in the single-bundle group: the result differed significantly between the augmentation and single-bundle groups (p = 0 .013). No significant difference in the Lysholm score or pivot-shift test was seen between the three groups (p = 0.09 and 0.65, respectively). In patients with good synovial coverage, three of the four measurements used revealed significant improvement in proprioceptive function (p = 0.177, 0.020, 0.034, and 0.026). We conclude that ACL augmentation is a reasonable treatment option for patients with favourable ACL remnants. Cite this article: Bone Joint J 2014;96-B:1325–32


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims

This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA.

Methods

Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 939 - 944
1 Jul 2016
Boonen B Schotanus MGM Kerens B van der Weegen W Hoekstra HJ Kort NP

Aims. We wished to compare the clinical outcome, as assessed by questionnaires and the rate of complications, in total knee arthroplasty (TKA) undertaken with patient-matched positioning guides (PMPGs) or conventional instruments. Patients and Methods. A total of 180 patients (74 men, 106 women; mean age 67 years) were included in a multicentre, adequately powered, double-blind, randomised controlled trial. The mean follow-up was 44 months (24 to 57). Results. There were no significant or clinically relevant differences between the two groups for all outcome measures (Knee Society Score, p = 0.807; Oxford Knee Score, p = 0.304; Western Ontario and McMaster osteoarthritis index, p = 0.753; visual analogue scale for pain, p = 0.227; EuroQol-5D-3L index score, p = 0.610; EuroQol-5D-3L VAS health, p = 0.968.) There was no difference in the rate of complications (p = 0.291). . Conclusion. PMPGs are already in relatively common use and their short-term clinical results are equal to conventional instrumented TKA. Cite this article: Bone Joint J 2016;98-B:939–44


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims

To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps.

Methods

In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 335 - 340
1 Mar 2006
Amin AK Patton JT Cook RE Brenkel IJ

A total of 370 consecutive primary total knee replacements performed for osteoarthritis were followed up prospectively at 6, 18, 36 and 60 months. The Knee Society score and complications (perioperative mortality, superficial and deep wound infection, deep-vein thrombosis and revision rate) were recorded. By dividing the study sample into subgroups based on the body mass index overall, the body mass index in female patients and the absolute body-weight. The outcome in obese and non-obese patients was compared. A repeated measures analysis of variance showed no difference in the Knee Society score between the subgroups. There was no statistically-significant difference in the complication rates for the subgroups studied. Obesity did not influence the clinical outcome five years after total knee replacement


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1467 - 1476
1 Nov 2017
van Hamersveld KT Marang-van de Mheen PJ Tsonaka R Valstar† ER Toksvig-Larsen S

Aims

The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs.

Patients and Methods

Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1050 - 1055
1 Aug 2016
Karachalios T Varitimidis S Bargiotas K Hantes M Roidis N Malizos KN

Aims

The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the long-term results obtained with this prosthesis by extending a previous evaluation.

Patients and Methods

We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and post-operative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1493 - 1499
1 Nov 2015
Pandit H Hamilton TW Jenkins C Mellon SJ Dodd CAF Murray DW

This prospective study reports the 15-year survival and ten-year functional outcome of a consecutive series of 1000 minimally invasive Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women, 52%, mean age 66 years; 32 to 88). These were implanted by two surgeons involved with the design of the prosthesis to treat anteromedial osteoarthritis and spontaneous osteonecrosis of the knee, which are recommended indications. Patients were prospectively identified and followed up independently for a mean of 10.3 years (5.3 to 16.6).

At ten years, the mean Oxford Knee Score was 40 (standard deviation (sd) 9; 2 to 48): 79% of knees (349) had an excellent or good outcome. There were 52 implant-related re-operations at a mean of 5.5 years (0.2 to 14.7). The most common reasons for re-operation were arthritis in the lateral compartment (2.5%, 25 knees), bearing dislocation (0.7%, seven knees) and unexplained pain (0.7%, seven knees). When all implant-related re-operations were considered as failures, the ten-year rate of survival was 94% (95% confidence interval (CI) 92 to 96) and the 15-year survival rate 91% (CI 83 to 98). When failure of the implant was the endpoint the 15-year survival was 99% (CI 96 to 100).

This is the only large series of minimally invasive UKAs with 15-year survival data. The results support the continued use of minimally invasive UKA for the recommended indications.

Cite this article: Bone Joint J 2015;97-B:1493–99.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1197 - 1200
1 Sep 2013
Zhaoning X Xu Y Shaoqi T Baiqiang H Kang S

A total of 187 patients with primary osteoarthritis (OA) of the knee undergoing total knee replacement (TKR) were randomly divided into two groups, one of which underwent synovectomy. The patients and assessors were blinded to the randomisation both before and after surgery. The duration of surgery, hospitalisation period, concealed bleeding, drainage volume, blood transfusion rate and range of movement of the knee at three days after the operation were analysed. Patients were followed up at four weeks and 12 months after their operation, and a visual analogue score (VAS) for pain, Knee Society score (KSS) and a patellar ballottement test were compared between the groups.

The mean amount of concealed bleeding was higher in the synovectomy group compared with the control group (1.24 l (0.08 to 3.28) vs 1.03 l (0.16 to 2.94); p = 0.042), as was the mean drainage volume (0.90 l (0.35 to 1.81) vs 0.81 (0.25 to 1.65); p = 0.030). The mean operating time was also higher in the synovectomy group compared with the controls (1.50 hours (1.34 to 1.75) vs 1.41 hours (1.21 to 1.79); p = 0.006). There were no significant differences in blood transfusion rate (p = 0.882), hospital stay (p = 0.805) or range of movement of the knee (p = 0.413) between the two groups. At four weeks and 12 months post-operatively there were no statistically significant differences in any of the measured parameters. We concluded that synovectomy confers no clinical advantages in TKR for primary OA while subjecting patients to higher levels of bleeding and longer operating times.

Cite this article: Bone Joint J 2013;95-B:1197–200.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 619 - 621
1 May 2014
Adelani MA Johnson SR Keeney JA Nunley RM Barrack RL

Haematomas, drainage, and other non-infectious wound complications following total knee replacement (TKR) have been associated with long-term sequelae, in particular, deep infection. However, the impact of these wound complications on clinical outcome is unknown. This study compares results in 15 patients re-admitted for wound complications within 90 days of TKR to 30 matched patients who underwent uncomplicated total knee replacements. Patients with wound complications had a mean age of 66 years (49 to 83) and mean body mass index (BMI) of 37 (21 to 54), both similar to that of patients without complications (mean age 65 years and mean BMI 35). Those with complications had lower mean Knee Society function scores (46 (0 to 100 vs 66 (20 to 100), p = 0.047) and a higher incidence of mild or greater pain (73% vs 33%, p = 0.01) after two years compared with the non re-admitted group. Expectations in patients with wound complications following TKR should be tempered, even in those who do not develop an infection.

Cite this article: Bone Joint J 2014;96-B:619–21.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 467 - 470
1 Apr 2007
Kim Y Kim J Kim D

We performed a prospective, randomised study to compare the results and rates of complications of primary total knee replacement performed using a quadriceps-sparing technique or a standard arthrotomy in 120 patients who had bilateral total knee replacements carried out under the same anaesthetic. The clinical results, pain scales, surgical and hospital data, post-operative complications and radiological results were compared.

No significant differences were found between the two groups with respect to the blood loss, knee score, function score, pain scale, range of movement or radiological findings. In contrast, the operating time (p = 0.0001) and the tourniquet time (p < 0.0001) were significantly longer in the quadriceps-sparing group, as was the rate of complications (p = 0.0468).

We therefore recommend the use of a standard arthrotomy with the shortest possible skin incision for total knee replacement.