Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity. We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.Aims
Methods
Whether patients with asymptomatic bacteriuria
should be investigated and treated before elective hip and knee replacement
is controversial, although it is a widespread practice. We conducted
a prospective observational cohort study with urine analyses before
surgery and three days post-operatively. Patients with symptomatic
urinary infections or an indwelling
The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA). This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC.Aims
Methods
A higher failure rate has been reported in haematogenous periprosthetic joint infection (PJI) compared to non-haematogenous PJI. The reason for this difference is unknown. We investigated the outcome of haematogenous and non-haematogenous PJI to analyze the risk factors for failure in both groups of patients. Episodes of knee or hip PJI (defined by the European Bone and Joint Infection Society criteria) treated at our institution between January 2015 and October 2020 were included in a retrospective PJI cohort. Episodes with a follow-up of > one year were stratified by route of infection into haematogenous and non-haematogenous PJI. Probability of failure-free survival was estimated using the Kaplan-Meier method, and compared between groups using log-rank test. Univariate and multivariate analysis was applied to assess risk factors for failure.Aims
Methods
Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm. We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model.Aims
Methods
In the absence of an identified organism, single-stage revision is contraindicated in prosthetic joint infection (PJI). However, no studies have examined the use of intra-articular antibiotics in combination with single-stage revision in these cases. In this study, we present the results of single-stage revision using intra-articular antibiotic infusion for treating culture-negative (CN) PJI. A retrospective analysis between 2009 and 2016 included 51 patients with CN PJI who underwent single-stage revision using intra-articular antibiotic infusion; these were compared with 192 culture-positive (CP) patients. CN patients were treated according to a protocol including intravenous vancomycin and a direct intra-articular infusion of imipenem and vancomycin alternately used in the morning and afternoon. In the CP patients, pathogen-sensitive intravenous (IV) antibiotics were administered for a mean of 16 days (12 to 21), and for resistant cases, additional intra-articular antibiotics were used. The infection healing rate, Harris Hip Score (HHS), and Hospital for Special Surgery (HSS) knee score were compared between CN and CP groups.Aims
Methods
The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management. A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).Aims
Patients and Methods
Tranexamic acid is a fibrinolytic inhibitor which reduces blood loss in total knee replacement. We examined the effect on blood loss of a standardised intravenous bolus dose of 1 g of tranexamic acid, given at the induction of anaesthesia in patients undergoing total hip replacement and tested the potential prothrombotic effect by undertaking routine venography. In all, 36 patients received 1 g of tranexamic acid, and 37 no tranexamic acid. Blood loss was measured directly per-operatively and indirectly post-operatively. Tranexamic acid reduced the early post-operative blood loss and total blood loss (p = 0.03 and p = 0.008, respectively) but not the intraoperative blood loss. The tranexamic acid group required fewer transfusions (p = 0.03) and had no increased incidence of deep-vein thrombosis. The reduction in early post-operative blood loss was more marked in women (p = 0.05), in whom this effect was dose-related (r = −0.793). Our study showed that the administration of a standardised pre-operative bolus of 1 g of tranexamic acid was cost-effective in reducing the blood loss and transfusion requirements after total hip replacement, especially in women.
A once-daily dose of rivaroxaban 10 mg, an oral, direct Factor Xa inhibitor, was compared with enoxaparin 40 mg subcutaneously once daily for prevention of venous thromboembolism in three studies of patients undergoing elective hip and knee replacement (RECORD programme). A pooled analysis of data from these studies (n = 9581) showed that rivaroxaban was more effective than enoxaparin in reducing the incidence of the composite of symptomatic venous thromboembolism and all-cause mortality at two weeks (0.4% vs 0.8%, respectively, odds ratio 0.44; 95% confidence interval 0.23 to 0.79; p = 0.005), and at the end of the planned medication period (0.5% vs 1.3%, respectively; odds ratio 0.38; 95% confidence interval 0.22 to 0.62; p <
0.001). The rate of major bleeding was similar at two weeks (0.2% for both) and at the end of the planned medication period (0.3% vs 0.2%). Rivaroxaban started six to eight hours after surgery was more effective than enoxaparin started the previous evening in preventing symptomatic venous thromboembolism and all-cause mortality, without increasing major bleeding.
Antibiotic prophylaxis is routinely administered during joint replacement surgery and may predispose patients to
Biofilm-associated infections in wounds or on implants are difficult to treat. Eradication of the bacteria is nearly always impossible, despite the use of specific antibiotics. The bactericidal effects of high-energy extracorporeal shock waves on The biofilm-cultured washers were exposed to low-energy shock waves at 0.16 mJ/mm2 for 500 impulses. The washers were then treated with cefuroxime, rifampicin and fosfomycin, both alone and in combination. All tests were carried out in triplicate. Viable cells were counted to determine the bactericidal effect. The control groups of We conclude that shock waves combined with antibiotics could be tested in an
Prophylaxis against venous thromboembolism after elective total hip replacement is routinely recommended. Our preference has been to use mechanical prophylaxis without anticoagulant drugs. A randomised controlled trial was performed to evaluate whether the incidence of post-operative venous thromboembolism was reduced by using pharmacological anticoagulation with either fondaparinux or enoxaparin in addition to our prophylactic mechanical regimen. A total of 255 Japanese patients who underwent primary unilateral cementless total hip replacement were randomly assigned to one of three postoperative regimens, namely injection of placebo (saline), fondaparinux or enoxaparin. There were 85 patients in each group. All also received the same mechanical prophylaxis during and after the operation, regardless of their assigned group. The primary measurement of efficacy was the presence of a venous thromboembolic event by day 11, defined as deep-vein thrombosis detected by ultrasonography, documented symptomatic deep-vein thrombosis or documented symptomatic pulmonary embolism. The duration of follow-up was 12 weeks. The rate of venous thromboembolism was 7.2% with the placebo, 7.1% with fondaparinux and 6.0% with enoxaparin (p = 0.95 for the comparison of all three groups). Our study confirmed the effectiveness and safety of mechanical thromboprophylaxis without the use of anticoagulant drugs after total hip replacement in Japanese patients.