We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior
To ascertain whether patients with Colles’ fracture should be investigated for osteoporosis and the risk of future fractures, we measured the
We have performed a form of lunate replacement arthroplasty, which included excision of the lunate and insertion of a vascularised radial
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
Methods. Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations (. sd. 1.2;1 to 8). All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or
We report the effectiveness of revision of total
elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows
in 52 patients were treated with re-cementing of a total elbow replacement
into part or all of the existing cement mantle or into the debrided
host-bone interface, without the use of structural
Aims. The aim of this study was to compare the pain caused by the application
of a tourniquet after exsanguination of the upper limb with that
occurring after simple elevation. . Patients and Methods. We used 26 healthy volunteers (52 arms), each of whom acted as
their own matched control. The primary outcome measure was the total pain experienced by
each volunteer while the tourniquet was inflated for 20 minutes.
This was calculated as the area under the pain curve for each individual
subject. Secondary outcomes were pain at each time point; the total
pain experienced during the recovery phase; the ability to tolerate the
tourniquet and the time for full recovery after deflation of the
tourniquet. . Results. There was a significant difference in the area under the pain
curves in favour of exsanguination (mean difference 8.4; 95% confidence
interval (CI) 3.0 to 13.7, p = 0.004). There was no difference between
the dominant and non-dominant arms (mean difference -0.2; 95% CI
-23.2 to 22.8, p = 0.99). The area under both recovery curves were similar
(mean difference 0.7; 95% CI -6.0 to 4.6, p = 0.78). There was no
statistical difference in recovery time, the actual mean difference
being 30 seconds longer in the elevation group (p = 0.06). Conclusion. Many orthopaedic and plastic surgery procedures are done under
local anaesthetic or regional block where a bloodless field and
a motionless patient are essential. Optimising patient comfort during
surgery with the tourniquet inflated is thus a priority. This study
is useful in that it compares two common methods of preparation
of the upper limb prior to tourniquet inflation and which have not
previously been compared in this context. Following on the results of this study, we can confidently conclude
that exsanguinating the upper limb before inflating a tourniquet
is more comfortable than simply elevating the arm for patients undergoing
a procedure under local or regional block, both during the procedure
and in the recovery phase. . Take home message: Exsanguination rather than elevation is recommended
in order to minimise patient discomfort and optimise the surgical
field. Cite this article:
We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range.
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439). Comparison of the post-operative radiographs between
the two groups showed no significant differences in lateral intrascaphoid
angle (p = 0.657) and scaphoid length
(p = 0.670) and height (p = 0.193). The radiolunate angle was significantly
different
(p = 0.020) but the mean value in both groups was <
10°. Comparison
of the dorsiflexion and palmar flexion of movement of the wrist
and the mean Mayo wrist score at the final clinical visit in each
group showed no significant difference (p = 0.190, p = 0.587 and
p = 0.265, respectively). Cancellous bone graft and K-wire fixation
were effective in the treatment of stable and unstable scaphoid
nonunion. Cite this article:
Follow-up radiographs are usually used as the
reference standard for the diagnosis of suspected scaphoid fractures. However,
these are prone to errors in interpretation. We performed a meta-analysis
of 30 clinical studies on the diagnosis of suspected scaphoid fractures,
in which agreement data between any of follow-up radiographs, bone scintigraphy,
magnetic resonance (MR) imaging, or CT could be obtained, and combined
this with latent class analysis to infer the accuracy of these tests
on the diagnosis of suspected scaphoid fractures in the absence
of an established standard. The estimated sensitivity and specificity
were respectively 91.1% and 99.8% for follow-up radiographs, 97.8%
and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2%
and 99.5% for CT. The results were generally robust in multiple
sensitivity analyses. There was large between-study heterogeneity
for the sensitivity of follow-up radiographs and CT, and imprecision
about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing
suspected scaphoid fractures, MRI is the most accurate test; follow-up
radiographs and CT may be less sensitive, and
Necrotising soft-tissue infections (NSTIs) of
the upper limb are uncommon, but potentially life-threatening. We
used a national database to investigate the risk factors for amputation
of the limb and death. . We extracted data from the Japanese Diagnosis Procedure Combination
database on 116 patients (79 men and 37 women) who had a NSTI of
the upper extremity between 2007 and 2010. The overall in-hospital mortality was 15.5%. Univariate analysis
of in-hospital mortality showed that the significant variables were
age (p = 0.015), liver dysfunction (p = 0.005), renal dysfunction
(P <
0.001), altered consciousness (p = 0.049), and sepsis (p
= 0.021). Logistic regression analysis showed that the factors associated with
death in hospital were age over 70 years (Odds Ratio (OR) 6.6; 95%
confidence interval (CI) 1.5 to 28.2; p = 0.011) and renal dysfunction
(OR 15.4; 95% CI 3.8 to 62.8; p <
0.001). Univariate analysis of limb amputation showed that the significant
variables were diabetes (p = 0.017) mellitus and sepsis (p = 0.001).
Multivariable logistic regression analysis showed that the factors
related to limb amputation were sepsis (OR 1.8; 95% CI 1.5 to 24.0;
p = 0.013) and diabetes mellitus (OR 1.6; 95% CI 1.1 to 21.1; p
= 0.038). . For NSTIs of the upper extremity, advanced age and renal dysfunction
are both associated with a higher rate of in-hospital mortality.
Sepsis and diabetes mellitus are both associated with a higher rate
of amputation. Cite this article:
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior dislocations of the shoulder underwent
a Latarjet procedure and were reviewed at a mean of 8.3 years (1
to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°)
to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°)
to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to
100) at the final follow-up. Radiologically, all shoulders showed
a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes
of the glenohumeral joint were observed in five shoulders (36%)
pre-operatively and in eight shoulders (57%) post-operatively.
Re-dislocation during a seizure occurred in six shoulders (43%).
Five of these patients underwent revision surgery using a
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. . Cite this article:
Malunion is the most common complication of the
distal radius with many modalities of treatment available for such
a problem. The use of bone grafting after an osteotomy is still
recommended by most authors. We hypothesised that
In adults with brachial plexus injuries, lack
of active external rotation at the shoulder is one of the most common residual
deficits, significantly compromising upper limb function. There
is a paucity of evidence to address this complex issue. We present
our experience of isolated latissimus dorsi (LD) muscle transfer
to achieve active external rotation. This is a retrospective review
of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus
dorsi muscle transfer to restore external rotation of the shoulder
between 1997 and 2010. All patients were male with a mean age of
34 years (21 to 57). All the patients underwent isolated LD muscle
transfer using a standard technique to correct external rotational
deficit. Outcome was assessed for improvement in active external rotation,
arc of movement, muscle strength and return to work. The mean improvement
in active external rotation from neutral was 24° (10° to 50°). The
mean increase in arc of rotation was 52° (38° to 55°). Mean power
of the external rotators was 3.5 Medical Research Council (MRC)
grades (2 to 5). A total of 21 patients (88%) were back in work by the time of
last follow up. Of these,
13 had returned to their pre-injury occupation. Isolated latissimus
dorsi muscle transfer provides a simple and reliable method of restoring
useful active external rotation in adults with brachial plexus injuries
with internal rotational deformity. Cite this article:
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Staphylococcus
epidermidis and Propionibacterium acnes;
two patients developed a recurrent infection. Three different types
of prosthesis were used: a hemiarthroplasty, a hemiarthroplasty
with a bipolar head and reverse prosthesis. The mean Constant-Murley
score at final follow-up was 43.3 (14 to 90) for patients with a
hemiarthroplasty, 56 (40 to 88) for those with a hemiarthroplasty
with a bipolar head and 61 (7 to 90) for those with a reverse prosthesis.
The mean hospital stay was 10.6 days (5 to 29). Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
This study provides recommendations on the position
of the implant in reverse shoulder replacement in order to minimise
scapular notching and osteophyte formation. Radiographs from 151
patients who underwent primary reverse shoulder replacement with
a single prosthesis were analysed at a mean follow-up of 28.3 months
(24 to 44) for notching, osteophytes, the position of the glenoid
baseplate, the overhang of the glenosphere, and the prosthesis scapular
neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four
Grade 2) and 47 (31.1%) had an osteophyte. In patients without either
notching or an osteophyte the baseplate was found to be positioned
lower on the glenoid, with greater overhang of the glenosphere and
a lower PSNA than those with notching and an osteophyte. Female patients
had a higher rate of notching than males (13.3% vs 13.0%)
but a lower rate of osteophyte formation (22.9% vs 50.0%),
even though the baseplate was positioned significantly lower on
the glenoid in females (p = 0.009) and each had a similar mean overhang
of the glenosphere. Based on these findings we make recommendations on the placement
of the implant in both male and female patients to avoid notching
and osteophyte formation. Cite this article: