When cerebral palsy involves the entire body pelvic asymmetry indicates that both hips are ‘at risk’. We carried out a six-year retrospective clinical, radiological and functional study of 30 children (60 hips) with severe cerebral palsy involving the entire body to evaluate whether bilateral simultaneous combined soft-tissue and bony surgery of the hip could affect the range of movement, achieve hip symmetry as judged by the windsweep index, improve the radiological indices of hip containment, relieve pain, and improve handling and function. The early results at a median follow-up of three years showed improvements in abduction and adduction of the hips in flexion, fixed flexion contracture, radiological containment of the hip using both Reimer’s migration percentage and the centre-edge angle of Wiberg, and in relief of pain. Ease of patient handling improved and the satisfaction of the carer with the results was high. There was no difference in outcome between the dystonic and hypertonic groups.
The results of a functional, clinical and radiological study of 30 children (60 hips) with whole-body cerebral palsy were reviewed at a mean follow-up of 10.2 years (9.5 to 11). Correction of windsweep deformity of the hips was performed by bilateral simultaneous combined soft-tissue and bony surgery at a mean age of 7.7 years (3.1 to 12.2). We were able to recall 22 patients; five had died of unrelated causes and three were lost to follow-up. Evaluation involved interviews with patients/carers and clinical and radiological examination. The gross motor functional classification system was used to assess overall motor function and showed improvement in seven patients. Of the 12 patients thought to have pain pre-operatively, only one had pain post-operatively. Improved handling was reported in 18 of 22 patients (82%). Those with handling problems were attributed by the carers to growth of the patients. All patients/carers considered the procedure worthwhile. The range of hip movements improved, and the mean windsweep index improved from 50 pre-operatively to 36 at follow-up. The migration percentage and centre-edge angle were assessed on plain radiographs. Radiological containment improved, the mean migration percentage improved from 50 pre-operatively to 20 at follow-up and the mean centre-edge angle improved from −5° to 29°. No statistical difference was noted between the three-year and ten-year follow-up results, indicating that the improvements in clinical and radiological outcome had been maintained.