To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.Aims
Methods
The aim of the Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) was to determine the optimal treatment for adults with a bicortical undisplaced or minimally displaced fracture of the waist of the scaphoid, comparing early surgical fixation with initial cast immobilization, with immediate fixation being offered to patients with nonunion. A cost-effectiveness analysis was conducted to assess the relative merits of these forms of treatment. The differences in costs to the healthcare system and quality-adjusted life years (QALYs) of the patients over the one-year follow-up of the trial in the two treatment arms were estimated using regression analysis.Aims
Methods
The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis.Aims
Methods
We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.Aims
Methods
The aim of this meta-analysis was to assess the safety and efficacy
of collagenase clostridium histolyticum compared with fasciectomy
and percutaneous needle fasciotomy (PNF) for Dupuytren’s disease. We systematically searched PubMed, EMBASE, LILACS, Web of Science,
Cochrane, Teseo and the ClinicalTrials.gov registry for clinical
trials and cohort or case-control studies which compared the clinical
outcomes and adverse effects of collagenase with those of fasciectomy
or PNF. Of 1345 articles retrieved, ten were selected. They described
the outcomes of 425 patients treated with collagenase and 418 treated
by fasciectomy or PNF. Complications were assessed using inverse-variance
weighted odds ratios (ORs). Clinical efficacy was assessed by differences
between the means for movement of the joint before and after treatment.
Dose adjustment was applied in all cases.Aims
Materials and Methods
Wrist block has been used to provide pain relief
for many procedures on the hand and wrist but its role in arthroscopy
of the wrist remains unexplored. Chondrotoxicity has been a concern
with the intra-articular infiltration of local anaesthetic. We aimed
to evaluate and compare the analgesic effect of portal and wrist
joint infiltration with a wrist block on the pain experienced by
patients after arthroscopy of the wrist. A prospective, randomised, double-blind trial was designed and
patients undergoing arthroscopy of the wrist under general anaesthesia
as a day case were recruited for the study. Levo-bupivacaine was
used for both techniques. The effects were evaluated using a ten-point
visual analogue scale, and the use of analgesic agents was also
compared. The primary outcomes for statistical analyses were the
mean pain scores and the use of analgesia post-operatively. A total of 34 patients (63% females) were recruited to the portal
and joint infiltration group and 32 patients (59% males) to the
wrist block group. Mean age was 40.8 years in the first group and
39.7 years in the second group (p >
0.05). Both techniques provided
effective pain relief in the first hour and 24 hours post-operatively
but wrist block gave better pain scores at bedtime on the day of
surgery (p = 0.007) and at 24 hours post-operatively (p = 0.006). Wrist block provides better and more reliable analgesia in patients
undergoing arthroscopy of the wrist without exposing patients to
the risk of chondrotoxicity. Cite this article:
Damage to the cartilage of the distal radioulnar
joint frequently leads to pain and limitation of movement, therefore repair
of this joint cartilage would be highly desirable. The purpose of
this study was to investigate the fixation of scaffold in cartilage
defects of this joint as part of matrix-assisted regenerative autologous
cartilage techniques. Two techniques of fixation of collagen scaffolds,
one involving fibrin glue alone and one with fibrin glue and sutures, were
compared in artificially created cartilage defects of the distal
radioulnar joint in a human cadaver. After being subjected to continuous
passive rotation, the methods of fixation were evaluated for cover
of the defect and pull out force. No statistically significant differences were found between the
two techniques for either cover of the defect or integrity of the
scaffold. However, a significantly increased mean pull out force
was found for the combined procedure, 0.665 N (0.150 to 1.160) This suggests that although successful fixation of a collagen
type I/III scaffold in a distal radioulnar joint cartilage defect
is feasible with both forms of fixation, fixation with glue and
sutures is preferable. Cite this article:
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article: