Advertisement for orthosearch.org.uk
Results 1 - 20 of 459
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 315 - 320
1 Mar 2011
Hart AJ Ilo K Underwood R Cann P Henckel J Lewis A Cobb J Skinner J

We measured the orientation of the acetabular and femoral components in 45 patients (33 men, 12 women) with a mean age of 53.4 years (30 to 74) who had undergone revision of metal-on-metal hip resurfacings. Three-dimensional CT was used to measure the inclination and version of the acetabular component, femoral version and the horizontal femoral offset, and the linear wear of the removed acetabular components was measured using a roundness machine. We found that acetabular version and combined version of the acetabular and femoral components were weakly positively correlated with the rate of wear. The acetabular inclination angle was strongly positively correlated with the rate of wear. Femoral version was weakly negatively correlated with the rate of wear. Application of a threshold of > 5 μm/year for the rate of wear in order to separate the revisions into low or high wearing groups showed that more high wearing components were implanted outside Lewinnek’s safe zone, but that this was mainly due to the inclination of the acetabular component, which was the only parameter that significantly differed between the groups. We were unable to show that excess version of the acetabular component alone or combined with femoral version was associated with an increase in the rate of wear based on our assessment of version using CT


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1010 - 1015
1 Aug 2020
Robinson PG Maempel JF Murray IR Rankin CS Hamilton DF Gaston P

Aims. Responsiveness and ceiling effects are key properties of an outcome score. No such data have been reported for the original English version of the International Hip Outcome Tool 12 (iHOT-12) at a follow-up of more than four months. The aim of this study was to identify the responsiveness and ceiling effects of the English version iHOT-12 in a series of patients undergoing hip arthroscopy for intra-articular hip pathology at a minimum of one year postoperatively. Methods. A total of 171 consecutive patients undergoing hip arthroscopy with a diagnosis of femoroacetabular impingement (FAI) under the care of a single surgeon between January 2013 and March 2017 were included. iHOT-12 and EuroQol 5D-5L (EQ-5D-5L) scores were available pre- and postoperatively. Effect size and ceiling effects for the iHOT-12 were calculated with subgroup analysis. Results. A total of 122 patients (71.3%) completed postoperative PROMs scores with median follow-up of 24.3 months (interquartile range (IQR) 17.2 to 33.5). The median total cohort iHOT-12 score improved significantly from 31.0 (IQR 20 to 58) preoperatively to 72.5 (IQR 47 to 90) postoperatively (p < 0.001). The effect size (Cohen’s d) was 1.59. In all, 33 patients (27%) scored within ten points (10%) of the maximum score and 38 patients (31.1%) scored within the previously reported minimal clinically important difference (MCID) of the maximum score. Furthermore, nine (47%) male patients aged < 30 years scored within 10% of the maximum score and ten (53%) scored within the previously reported MCID of the maximum score. Conclusion. There is a previously unreported ceiling effect of the iHOT-12 at a minimum one-year follow-up which is particularly marked in young, male patients following hip arthroscopy for FAI. This tool may not have the maximum measurement required to capture the true outcome following this procedure. Cite this article: Bone Joint J 2020;102-B(8):1010–1015


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 306 - 311
1 Mar 2015
Weber M Lechler P von Kunow F Völlner F Keshmiri A Hapfelmeier A Grifka J Renkawitz T

Femoral stem version has a major influence on impingement and early post-operative stability after total hip arthroplasty (THA). The main objective of this study was to evaluate the validity of a novel radiological method for measuring stem version. Anteroposterior (AP) radiographs and three-dimensional CT scans were obtained for 115 patients (female/male 63/72, mean age 62.5 years (50 to 75)) who had undergone minimally invasive, cementless THA. Stem version was calculated from the AP hip radiograph by rotation-based change in the projected prosthetic neck–shaft (NSA*) angle using the mathematical formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent observers who repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. We found a mean difference of 1.2° (. sd. 6.2) between radiological and 3D-CT measurements of stem version. The correlation between the mean radiological and 3D-CT stem torsion was r = 0.88 (p < 0.001). The intra- (intraclass correlation coefficient ≥ 0.94) and inter-observer agreement (mean concordance correlation coefficient = 0.87) for the radiological measurements were excellent. We found that femoral tilt was associated with the mean radiological measurement error (r = 0.22, p = 0.02). . The projected neck–shaft angle is a reliable method for measuring stem version on AP radiographs of the hip after a THA. However, a highly standardised radiological technique is required for its precise measurement. . Cite this article: Bone Joint J 2015; 97-B:306–11


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1356 - 1362
1 Oct 2010
Simpson DJ Kendrick BJL Hughes M Glyn-Jones S Gill HS Rushforth GF Murray DW

We have evaluated the difference in the migration patterns over two years of two cementless stems in a randomised, controlled trial using radiostereophotogrammetric analysis (RSA). The implants studied were the Furlong HAC stem, which has good long-term results and the Furlong Active stem, which is a modified version of the former designed to minimise stress concentrations between the implant and bone, and thus to improve fixation. A total of 23 Furlong HAC and 20 Furlong Active stems were implanted in 43 patients. RSA examinations were carried out immediately post-operatively and at six, 12 and 24 months post-operatively. The subsidence during the first year in the Furlong HAC stem, was approximately one-third that of the Furlong Active stem, the measured mean subsidence of the femoral head at six months being 0.27 mm (95% confidence interval (CI) 0.03 to 0.51) and 0.99 mm (95% CI 0.38 to 1.60), respectively (p = 0.03). One Active stem continued to subside during the second year. All hips, regardless of the type of stem were clinically successful as judged by the Oxford hip score and a derived pain score without any distinction between the two types of stem. The initial stability of the Furlong Active stem was not as good as the established stem which might compromise osseo-integration to the detriment of long-term success. The changes in the geometry of the stem, to minimise stress have affected the attainment of initial stability


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 877 - 880
1 Jul 2013
Lee YK Kim TY Ha YC Kang BJ Koo KH

Version of the femoral stem is an important factor influencing the risk of dislocation after total hip replacement (THR) as well as the position of the acetabular component. However, there is no radiological method of measuring stem anteversion described in the literature. We propose a radiological method to measure stem version and have assessed its reliability and validity. In 36 patients who underwent THR, a hip radiograph and CT scan were taken to measure stem anteversion. The radiograph was a modified Budin view. This is taken as a posteroanterior radiograph in the sitting position with 90° hip flexion and 90° knee flexion and 30° hip abduction. The angle between the stem-neck axis and the posterior intercondylar line was measured by three independent examiners. The intra- and interobserver reliabilities of each measurement were examined. The radiological measurements were compared with the CT measurements to evaluate their validity. The mean radiological measurement was 13.36° (. sd. 6.46) and the mean CT measurement was 12.35° (. sd. 6.39) (p = 0.096). The intra- and interobserver reliabilities were excellent for both measurements. The radiological measurements correlated well with the CT measurements (p = 0.001, r = 0.877). The modified Budin method appears reliable and valid for the measurement of femoral stem anteversion. Cite this article: Bone Joint J 2013;95-B:877–80


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. Methods. In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. Results. Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. Conclusion. Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time. Cite this article: Bone Joint J 2022;104-B(11):1196–1201


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 128 - 135
1 Feb 2024
Jenkinson MRJ Cheung TCC Witt J Hutt JRB

Aims. The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR. Methods. A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs. Results. Acetabular version was significantly lower and measurements of external rotation of the hemipelvis were significantly increased in the AR group compared to the control group. The AR group also had increased evidence of anterior projection of the iliac wing in the sagittal plane. The acetabular orientation angles were more retroverted in the supine compared to standing position, and the change in acetabular version correlated with the change in sagittal pelvic tilt. An anterior pelvic tilt of 1° correlated with 1.02° of increased cranial retroversion and 0.76° of increased central retroversion. Conclusion. This study has demonstrated that patients with symptomatic AR have both an externally rotated hemipelvis and increased anterior projection of the iliac wing compared to a control group of asymptomatic patients. Functional sagittal pelvic positioning was also found to affect AR in symptomatic patients: the acetabulum was more retroverted in the supine position compared to standing position. Changes in acetabular version correlate with the change in sagittal pelvic tilt. These findings should be taken into account by surgeons when planning acetabular correction for AR with periacetabular osteotomy. Cite this article: Bone Joint J 2024;106-B(2):128–135


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims. The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods. Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results. Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion. The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 735 - 742
1 Jul 2023
Andronic O Germann C Jud L Zingg PO

Aims. This study reports mid-term outcomes after periacetabular osteotomy (PAO) exclusively in a borderline hip dysplasia (BHD) population to provide a contrast to published outcomes for arthroscopic surgery of the hip in BHD. Methods. We identified 42 hips in 40 patients treated between January 2009 and January 2016 with BHD defined as a lateral centre-edge angle (LCEA) of ≥ 18° but < 25°. A minimum five-year follow-up was available. Patient-reported outcomes (PROMs) including Tegner score, subjective hip value (SHV), modified Harris Hip Score (mHHS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed. The following morphological parameters were evaluated: LCEA, acetabular index (AI), α angle, Tönnis staging, acetabular retroversion, femoral version, femoroepiphyseal acetabular roof index (FEAR), iliocapsularis to rectus femoris ratio (IC/RF), and labral and ligamentum teres (LT) pathology. Results. The mean follow-up was 96 months (67 to 139). The SHV, mHHS, WOMAC, and Tegner scores significantly improved (p < 0.001) at last follow-up. According to SHV and mHHS, there were three hips (7%) with poor results (SHV < 70), three (7%) with a fair score (70 to 79), eight (19%) with good results (80 to 89), and 28 (67%) who scored excellent (> 90) at the last follow-up. There were 11 subsequent operations: nine implant removals due to local irritation, one resection of postoperative heterotopic ossification, and one hip arthroscopy for intra-articular adhesions. No hips were converted to total hip arthroplasty at last follow-up. The presence of preoperative labral lesions or LT lesions did not influence any PROMs at last follow-up. From the three hips that had poor PROMs, two have developed severe osteoarthritis (> Tönnis II), presumably due to surgical overcorrection (postoperative AI < -10°). Conclusion. PAO is reliable in treating BHD with favourable mid-term outcomes. Concomitant LT and labral lesions did not negatively influence outcomes in our cohort. Technical accuracy with avoidance of overcorrection is essential in achieving successful outcomes. Cite this article: Bone Joint J 2023;105-B(7):735–742


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 47 - 51
1 Jul 2020
Kazarian GS Schloemann DT Barrack TN Lawrie CM Barrack RL

Aims. The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA). Methods. This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful. Results. Pelvic ratio decreased (posterior tilt) in 54.0% (27) of cases, did not change significantly in 34.0% (17) of cases, and increased (anterior tilt) in 12.0% (6) of cases when comparing preoperative to one-year postoperative radiographs. This would correspond with 5° to 10° of abduction error in 22.0% of cases and > 10° of error in 6.0%. Likewise, this would correspond with 5° to 10° of version error in 22.0% of cases and > 10° of error in 44.0%. Conclusion. Pelvic sagittal alignment is dynamic and variable after THA, and these changes persist to the one-year postoperative period, altering the orientation of the acetabular component. Surgeons who individualize the acetabular component placement based on preoperative functional radiographs should consider that the rotation of the pelvis (and thus the component version and inclination) changes one year postoperatively. Cite this article: Bone Joint J 2020;102-B(7 Supple B):47–51


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims. The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). Patients and Methods. A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (. sd. 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared. Results. The system reported accurate values for reconstruction of the hip when compared to those measured postoperatively using CT. The mean deviation from the executed overall hip length and offset were 1.6 mm (. sd. 2.9) and 0.5 mm (. sd. 3.0), respectively. Mean combined anteversion was similar and correlated between intraoperative measurements and postoperative CT measurements (32.5°, . sd. 5.9° versus 32.2°, . sd. 6.4°; respectively; R. 2. = 0.65; p < 0.001). There was a significant correlation between mean intraoperative (40.4°, . sd. 2.1°) acetabular component inclination and mean measured postoperative inclination (40.12°, . sd. 3.0°, R. 2. = 0.62; p < 0.001). There was a significant correlation between mean intraoperative version (23.2°, . sd. 2.3°), and postoperatively measured version (23.0°, . sd. 2.4°; R. 2. = 0.76; p < 0.001). Preoperative and postoperative femoral component anteversion were significantly correlated with one another (R. 2. = 0.64; p < 0.001). Three patients had CT scan measurements that differed substantially from the intraoperative robotic measurements when evaluating stem anteversion. Conclusion. This is the first study to evaluate the success of hip reconstruction overall using robotic-assisted THA. The overall hip reconstruction obtained in the operating theatre using robotic assistance accurately correlated with the postoperative component position assessed independently using CT based 3D modelling. Clinical correlation during surgery should continue to be practiced and compared with observed intraoperative robotic values. Cite this article: Bone Joint J 2018;100-B:1303–9


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 37 - 43
1 Jan 2016
Beverland DE O’Neill CKJ Rutherford M Molloy D Hill JC

Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality. . The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):37–43


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 45 - 50
1 Jun 2019
Schloemann DT Edelstein AI Barrack RL

Aims. The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position. Patients and Methods. We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (. sd. 10.7) and the mean body mass index (BMI) was 20.0 kg/m. 2. (. sd. 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant. Results. Intraoperatively, in the lateral decubitus position, the pelvic ratio increased (anterior tilt) in 69.4% of cases, did not change significantly in 20.4%, and decreased (posterior tilt) in 10.2% of cases. When six-week postoperative radiographs were compared with preoperative radiographs, the pelvic ratio decreased in 44.9% of cases, did not change significantly in 42.3%, and increased in 12.8% of cases. This change in alignment correlated with a change in acetabular component version of > 5° in 79.6% of cases intraoperatively and 57.7% of cases at six weeks postoperatively. Conclusion. Changes in pelvic sagittal pelvic position occur throughout THA that, if unaccounted for, introduce errors in acetabular component placement. The use of intraoperative imaging may help the appropriate placement of the acetabular component. Cite this article: Bone Joint J 2019;101-B(6 Supple B):45–50


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 727 - 729
1 Jun 2006
Kim WY Hutchinson CE Andrew JG Allen PD

Excessive acetabular cover secondary to a retroverted acetabulum causes pincer impingement, which may cause early osteoarthritis of the hip. Our aim was to determine if there was a relationship between acetabular version and osteoarthritis of the hip. Using image processing and analysis software we studied 117 CT images of the hip in patients aged less than 65 years who had undergone a CT virtual colonoscopy. The mean CT joint space of the 18 hips with acetabular retroversion was narrower compared with the 99 hips with normal acetabular alignment (p < 0.0001). A correlation of r = 0.46 (p < 0.01) was found between right hip acetabular version and the mean right hip joint space and of r = 0.31 (p = 0.02) between left hip acetabular version and the mean left hip joint space. Acetabular retroversion is associated with radiological evidence of osteoarthritis of the hip. An understanding of the mechanical basis of osteoarthritis of the hip allows early treatment of the underlying structural abnormality and prevents progression of the degenerative condition


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction. Materials and Methods. This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (. sd. 5.2) vs 67.5 years (. sd. 5.8) (p = 0.25); body mass index (27.4 kg/m. 2. (. sd. 2.1) vs 26.9 kg/m. 2. (. sd. 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs. Results. The correlation coefficient was 0.92 (95% confidence interval (CI) 0.88 to 0.95) for intraobserver agreement and 0.88 (95% CI 0.82 to 0.94) for interobserver agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p < 0.001) and vertical (p < 0.001) centres of rotation, and improved preservation of the patient’s native combined offset (p < 0.001) compared with conventional THA. Robotic THA improved accuracy in positioning of the acetabular component within the combined safe zones of inclination and anteversion described by Lewinnek et al (p = 0.02) and Callanan et al (p = 0.01) compared with conventional THA. There was no difference between the two treatment groups in achieving the planned leg-length correction (p = 0.10). Conclusion. Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular component positioning within the safe zones of inclination and anteversion compared with conventional manual THA


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 839 - 844
1 Jul 2018
Ollivier M Laumonerie P LiArno S Faizan A Cavaignac E Argenson J

Aims. In patients where the proximal femur shows gross deformity due to degenerative changes or fracture, the contralateral femur is often used to perform preoperative templating for hip arthroplasty. However, femurs may not be symmetrical: the aim of this study was to determine the degree of variation between hips in healthy individuals and to determine whether it is affected by demographic parameters. Materials and Methods. CT-scan based modelling was used to examine the pelvis and bilateral femurs of 345 patients (211 males, 134 women; mean age 62 years (standard deviation (. sd). 17), mean body mass index 27 kg/m. 2. (. sd. 5)) representing a range of ethnicities. The femoral neck-shaft angle (NSA), femoral offset (FO), femoral neck version (FNV), femoral length (FL), femoral canal flare index (fCFI), and femoral head radius (FHr) were then determined for each patient. All measurements were constructed using algorithm-calculated landmarks, resulting in reproducible and consistent constructs for each specimen. We then analyzed femoral symmetry based on absolute differences (AD) and percentage asymmetry (%AS) following a previously validated method. Results. We found an asymmetry > 2% for NSA (mean AD 2.9°, mean %AS 2.3; p = 0.03), FO (AD 3.8 mm, %AS 9.1 ; p = 0.01), FNV (AD 5.1°, %AS 46.7 ; p = 0.001) and fCFI (AD 0.2 mm, %AS 5.4 ; p = 0.7). Significant relationships were found for AD regarding NSA and ethnicity (p = 0.037), FL and height (R. 2.  = 0.22), and fCFI and gender (R. 2.  = 0.34). Conclusion. Our data confirm the presence of asymmetry of proximal femurs, which is mostly independent of demographic parameters. In cases where contralateral templating is used, such asymmetry may lead to inaccurate anatomical restoration of the hip if the templated sizes are routinely implanted. However, the clinical impact cannot be determined from our investigation. Cite this article: Bone Joint J 2018;100-B:839–44


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 314 - 319
1 Mar 2013
Masjedi M Nightingale CL Azimi DY Cobb JP

We examined the relationship between the size of the femoral cam in femoroacetabular impingement (FAI) and acetabular pathomorphology to establish if pincer impingement exists in patients with a femoral cam. CT scans of 37 symptomatic impinging hips with a femoral cam were analysed in a three-dimensional study and were compared with 34 normal hips. The inclination and version of the acetabulum as well as the acetabular rim angle and the bony acetabular coverage were calculated. These measurements were correlated with the size and shape of the femoral cams. While the size of the femoral cam varied characteristically, the acetabular morphology of the two groups was similar in terms of version (normal mean 23° (. sd. 7°); cam mean 22° (. sd.  9°)), inclination (normal mean 57° (. sd. 5°); cam mean 56° (. sd. 5°)), acetabular coverage (normal mean 41% (. sd. 5%); cam mean 42% (. sd. 4%)) and the mean acetabular rim angle (normal mean 82° (. sd. 5°); cam mean 83° (. sd. 4°)). We found no correlation between acetabular morphology and the severity of cam lesion and no evidence of either global or focal over-coverage to support the diagnosis of ‘mixed’ FAI. The femoral cam may provoke edge loading but removal of any acetabular bearing surface when treating cam FAI might induce accelerated wear. Cite this article: Bone Joint J 2013;95-B:314–19


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.