Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims

Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions.

Methods

We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 23 - 30
1 Jun 2019
Neufeld ME Masri BA

Aims

The aim of this study was to determine if the Oxford Knee and Hip Score (OKHS) can accurately predict when a primary knee or hip referral is deemed nonsurgical versus surgical by the surgeon during their first consultation, and to identify nonsurgical OKHS screening thresholds.

Patients and Methods

We retrospectively reviewed pre-consultation OKHS for all consecutive primary total knee arthroplasty (TKA) and total hip arthroplasty (THA) consultations of a single surgeon over three years. The 1436 knees (1016 patients) and 478 hips (388 patients) included were categorized based on the surgeon’s decision into those offered surgery during the first consultation versus those not (nonsurgical). Spearman’s rank correlation coefficients and receiver operating characteristic (ROC) curve analysis were performed.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 9 - 15
1 Jun 2019
Wyles CC Hevesi M Osmon DR Park MA Habermann EB Lewallen DG Berry DJ Sierra RJ

Aims

The aims of this study were to characterize antibiotic choices for perioperative total knee arthroplasty (TKA) and total hip arthroplasty (THA) prophylaxis, assess antibiotic allergy testing efficacy, and determine rates of prosthetic joint infection (PJI) based on perioperative antibiotic regimen.

Patients and Methods

We evaluated all patients undergoing primary TKA or THA at a single academic institution between January 2004 and May 2017, yielding 29 695 arthroplasties (22 705 patients), with 3411 arthroplasties in 2576 patients (11.5%) having undergone preoperative allergy testing. A series of institutional databases were combined to identify allergy consultation outcomes, perioperative antibiotic regimen, and infection-free survivorship until final follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 85 - 89
1 Jul 2020
Barrack TN Abu-Amer W Schwabe MT Adelani MA Clohisy JC Nunley RM Lawrie CM

Aims. Routine surveillance of primary hip and knee arthroplasties has traditionally been performed with office follow-up visits at one year postoperatively. The value of these visits is unclear. The present study aims to determine the utility and burden of routine clinical follow-up at one year after primary arthroplasty to patients and providers. Methods. All patients (473) who underwent primary total hip (280), hip resurfacing (eight), total knee (179), and unicompartmental knee arthroplasty (six) over a nine-month period at a single institution were identified from an institutional registry. Patients were prompted to attend their routine one-year postoperative visit by a single telephone reminder. Patients and surgeons were given questionnaires at the one-year postoperative visit, defined as a clinical encounter occurring at nine to 15 months from the date of surgery, regarding value of the visit. Results. Compliance with routine follow-up at one year was 35%. The response rate was over 80% for all questions in the patient and clinician surveys. Overall, 75% of the visits were for routine surveillance. Patients reported high satisfaction with their visits despite the general time for attendance, including travel, being over four hours. Surgeons found the visits more worthwhile when issues were identified or problems were addressed. Conclusion. Patient compliance with follow-up at one year postoperatively after primary hip and knee is low. Routine visits of asymptomatic patients deliver little practical value and represent a large time and cost burden for patients and surgeons. Remote strategies should be considered for routine postoperative surveillance primary hip and knee arthroplasties beyond the acute postoperative period. Cite this article: Bone Joint J 2020;102-B(7 Supple B):85–89


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1447 - 1458
1 Nov 2019
Chatziagorou G Lindahl H Kärrholm J

Aims

We investigated patient characteristics and outcomes of Vancouver type B periprosthetic fractures treated with femoral component revision and/or osteosynthesis.

Patients and Methods

The study utilized data from the Swedish Hip Arthroplasty Register (SHAR) and information from patient records. We included all primary total hip arthroplasties (THAs) performed in Sweden since 1979, and undergoing further surgery due to Vancouver type B periprosthetic femoral fracture between 2001 and 2011. The primary outcome measure was any further reoperation between 2001 and 2013. Cross-referencing with the National Patient Register was performed in two stages, in order to identify all surgical procedures not recorded on the SHAR.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1298 - 1303
1 Oct 2017
Schouten R Malone AA Frampton CM Tiffen C Hooper G

Aims

The primary aim of this independent prospective randomised trial was to compare serum metal ion levels for ceramic-on-metal (CoM) and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty (THA). Our one-year results demonstrated elevation in metal ion levels above baseline with no significant difference between the CoM and MoM groups. This paper reviews the five-year data.

Patients and Methods

The implants used in each patient differed only in respect to the type of femoral head (ceramic or metal). At five-year follow-up of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available for comparison.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1290 - 1297
1 Oct 2017
Devane PA Horne JG Foley G Stanley J

Aims

This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient’s bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA).

Materials and Methods

Models of the patient’s acetabular and femoral component obtained from the manufacturer and models of the patient’s pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 766 - 773
1 Jun 2017
Graves SE de Steiger R Davidson D Donnelly W Rainbird S Lorimer MF Cashman KS Vial RJ

Aims

Femoral stems with exchangeable (modular) necks were introduced to offer surgeons an increased choice when determining the version, offset and length of the femoral neck during total hip arthroplasty (THA). It was hoped that this would improve outcomes and reduce complications, particularly dislocation. In 2010, the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) first reported an increased rate of revision after primary THA using femoral stems with an exchangeable neck. The aim of this study was to provide a more comprehensive up-to-date analysis of primary THA using femoral stems with exchangeable and fixed necks.

Materials and Methods

The data included all primary THA procedures performed for osteoarthritis (OA), reported to the AOANJRR between 01 September 1999 and 31 December 2014. There were 9289 femoral stems with an exchangeable neck and 253 165 femoral stems with a fixed neck. The characteristics of the patients and prostheses including the bearing surface and stem/neck metal combinations were examined using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 3 - 10
1 Apr 2017
Parvizi J Shohat N Gehrke T

The World Health Organization (WHO) and the Centre for Disease Control and Prevention (CDC) recently published guidelines for the prevention of surgical site infection. The WHO guidelines, if implemented worldwide, could have an immense impact on our practices and those of the CDC have implications for healthcare policy in the United States.

Our aim was to review the strategies for prevention of periprosthetic joint infection in light of these and other recent guidelines.

Cite this article: Bone Joint J 2017;99-B(4 Supple B):3–10.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1180 - 1184
1 Sep 2016
Watts C Martin JR Houdek M Abdel M Lewallen D Taunton M

Aims

We compared the outcome of total hip arthroplasty (THA) in obese patients who previously underwent bariatric surgery and those who did not, in a matched cohort study.

Patients and Methods

There were 47 THAs in the bariatric group (42 patients), and 94 THAs in the comparison group (92 patients). The mean age of the patients was 57 years in both groups (24 to 79) and 57% of the patients in both groups were women. The mean time between bariatric surgery and THA was five years (four months to 12 years) in the bariatric group. The mean follow-up after THA was three years (2 to 9).


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 326 - 333
1 Mar 2016
Morvan A Moreau S Combourieu B Pansard E Marmorat JL Carlier R Judet T Lonjon G

Aims

The primary aim of this study was to analyse the position of the acetabular and femoral components in total hip arthroplasty undertaken using an anterior surgical approach.

Patients and Methods

In a prospective, single centre study, we used the EOS imaging system to analyse the position of components following THA performed via the anterior approach in 102 patients (103 hips) with a mean age of 64.7 years (sd 12.6). Images were taken with patients in the standing position, allowing measurement of both anatomical and functional anteversion of the acetabular component.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1604 - 1607
1 Dec 2015
Wassilew GI Perka C Janz V Krämer M Renner L

We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure.

A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment.

The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (sd) 0.9) vs 1.5 L (sd 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group.

The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE.

Cite this article: Bone Joint J 2015;97-B:1604–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 157 - 166
1 Nov 2012
Rosenberg AG Berend ME Berry DJ Della Valle CJ MacDonald SJ Minas T

This conversation represents an attempt by several arthroplasty surgeons to critique several abstracts presented over the last year as well as to use them as a jumping off point for trying to figure out where they fit in into our current understanding of multiple issues in modern hip and knee arthroplasty.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 462 - 466
1 Apr 2014
Graham SM Lubega N Mkandawire N Harrison WJ

We report the short-term follow-up, functional outcome and incidence of early and late infection after total hip replacement (THR) in a group of HIV-positive patients who do not suffer from haemophilia or have a history of intravenous drug use. A total of 29 patients underwent 43 THRs, with a mean follow-up of three years and six months (five months to eight years and two months). There were ten women and 19 men, with a mean age of 47 years and seven months (21 years to 59 years and five months). No early (< 6 weeks) or late (> 6 weeks) complications occurred following their THR. The mean pre-operative Harris hip score (HHS) was 27 (6 to 56) and the mean post-operative HHS was 86 (73 to 91), giving a mean improvement of 59 points (p = < 0.05, Student’s t-test). No revision procedures had been undertaken in any of the patients, and none had any symptoms consistent with aseptic loosening. This study demonstrates that it is safe to perform THR in HIV-positive patients, with good short-term functional outcomes and no apparent increase in the risk of early infection.

Cite this article: Bone Joint J 2014; 96-B:462–6.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs.

Cite this article: Bone Joint J 2013;95-B:1458–63.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1445 - 1449
1 Nov 2013
Sonnadara R McQueen S Mironova P Safir O Nousiainen M Ferguson P Alman B Kraemer W Reznick R

Valid and reliable techniques for assessing performance are essential to surgical education, especially with the emergence of competency-based frameworks. Despite this, there is a paucity of adequate tools for the evaluation of skills required during joint replacement surgery. In this scoping review, we examine current methods for assessing surgeons’ competency in joint replacement procedures in both simulated and clinical environments. The ability of many of the tools currently in use to make valid, reliable and comprehensive assessments of performance is unclear. Furthermore, many simulation-based assessments have been criticised for a lack of transferability to the clinical setting. It is imperative that more effective methods of assessment are developed and implemented in order to improve our ability to evaluate the performance of skills relating to total joint replacement. This will enable educators to provide formative feedback to learners throughout the training process to ensure that they have attained core competencies upon completion of their training. This should help ensure positive patient outcomes as the surgical trainees enter independent practice.

Cite this article: Bone Joint J 2013;95-B:1445–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1183 - 1188
1 Sep 2011
Biau DJ Meziane M Bhumbra RS Dumaine V Babinet A Anract P

The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance.

The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1066 - 1071
1 Aug 2010
Chee YH Teoh KH Sabnis BM Ballantyne JA Brenkel IJ

We compared 55 consecutive total hip replacements performed on 53 morbidly obese patients with osteoarthritis with a matched group of 55 total hip replacements in 53 non-obese patients. The groups were matched for age, gender, prosthesis type, laterality and preoperative Harris Hip Score. They were followed prospectively for five years and the outcomes were assessed using the Harris Hip Score, the Short-form 36 score and radiological findings.

Survival at five years using revision surgery as an endpoint, was 90.9% (95% confidence interval 82.9 to 98.9) for the morbidly obese and 100% for the non-obese patients. The Harris Hip and the Short-form 36 scores were significantly better in the non-obese group (p < 0.001). The morbidly obese patients had a higher rate of complications (22% vs 5%, p = 0.012), which included dislocation and both superficial and deep infection.

In light of these inferior results, morbidly obese patients should be advised to lose weight before undergoing a total hip replacement, and counselled regarding the complications. Despite these poorer results, however, the patients have improved function and quality of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1299 - 1302
1 Oct 2006
Tillman R Kalra S Grimer R Carter S Abudu A

Peri- and sub-prosthetic fractures, or pathological fractures below an existing well-fixed femoral component, with or without an ipsilateral knee replacement, present a difficult surgical challenge.

We describe a simple solution, in which a custom-made prosthesis with a cylindrical design is cemented proximally to the stem of an existing, well-fixed femoral component. This effectively treats the fracture without sacrificing the good hip. We describe five patients with a mean age of 73 years (60 to 81) and a mean follow-up of 47 months (6 to 108).

The mean overlap of the prosthesis over the femoral component was 7.5 cm (5.5 to 10). There have been no mechanical failures, no new infections and no re-operations. We suggest that in highly selected cases, in which conventional fixation is not feasible, this technique offers a durable option and avoids the morbidity of a total femoral replacement.