Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella. We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order. . The reliability was assessed using the Kappa and weighted Kappa values. The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users. Cite this article: Bone Joint J 2014;96-B:1669–73


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 593 - 599
1 May 2020
Amanatullah DF Cheng RZ Huddleston III JI Maloney WJ Finlay AK Kappagoda S Suh GA Goodman SB

Aims. To establish the utility of adding the laboratory-based synovial alpha-defensin immunoassay to the traditional diagnostic work-up of a prosthetic joint infection (PJI). Methods. A group of four physicians evaluated 158 consecutive patients who were worked up for PJI, of which 94 underwent revision arthroplasty. Each physician reviewed the diagnostic data and decided on the presence of PJI according to the 2014 Musculoskeletal Infection Society (MSIS) criteria (yes, no, or undetermined). Their initial randomized review of the available data before or after surgery was blinded to each alpha-defensin result and a subsequent randomized review was conducted with each result. Multilevel logistic regression analysis assessed the effect of having the alpha-defensin result on the ability to diagnose PJI. Alpha-defensin was correlated to the number of synovial white blood cells (WBCs) and percentage of polymorphonuclear cells (%PMN). Results. Intraobserver reliability and interobserver agreement did not change when the alpha-defensin result was available. Positive alpha-defensin results had greater synovial WBCs (mean 31,854 cells/μL, SD 32,594) and %PMN (mean 93.0%, SD 5.5%) than negative alpha-defensin results (mean 974 cells/μL, SD 3,988; p < 0.001 and mean 39.4% SD 28.6%; p < 0.001). Adding the alpha-defensin result did not alter the diagnosis of a PJI using preoperative (odds ratio (OR) 0.52, 95% confidence interval (CI) 0.14 to 1.88; p = 0.315) or operative (OR 0.52, CI 0.18 to 1.55; p = 0.242) data when clinicians already decided that PJI was present or absent with traditionally available testing. However, when undetermined with traditional preoperative testing, alpha-defensin helped diagnose (OR 0.44, CI 0.30 to 0.64; p < 0.001) or rule out (OR 0.41, CI 0.17 to 0.98; p = 0.044) PJI. Of the 27 undecided cases with traditional testing, 24 (89%) benefited from the addition of alpha-defensin testing. Conclusion. The laboratory-based synovial alpha-defensin immunoassay did not help diagnose or rule out a PJI when added to routine serologies and synovial fluid analyses except in cases where the diagnosis of PJI was unclear. We recommend against the routine use of alpha-defensin and suggest using it only when traditional testing is indeterminate. Cite this article: Bone Joint J 2020;102-B(5):593–599


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 688 - 695
1 Jul 2024
Farrow L Zhong M Anderson L

Aims

To examine whether natural language processing (NLP) using a clinically based large language model (LLM) could be used to predict patient selection for total hip or total knee arthroplasty (THA/TKA) from routinely available free-text radiology reports.

Methods

Data pre-processing and analyses were conducted according to the Artificial intelligence to Revolutionize the patient Care pathway in Hip and knEe aRthroplastY (ARCHERY) project protocol. This included use of de-identified Scottish regional clinical data of patients referred for consideration of THA/TKA, held in a secure data environment designed for artificial intelligence (AI) inference. Only preoperative radiology reports were included. NLP algorithms were based on the freely available GatorTron model, a LLM trained on over 82 billion words of de-identified clinical text. Two inference tasks were performed: assessment after model-fine tuning (50 Epochs and three cycles of k-fold cross validation), and external validation.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 706 - 711
1 Jul 2003
Whitehouse SL Lingard EA Katz JN Learmonth ID

We used prospective data from 862 total knee and 716 total hip replacements three years after surgery in order to derive and validate a reduced Western Ontario and McMasters University Osteoarthritis Index (WOMAC) function scale. The reduced scale was derived using the advice of clinical experts as well as analysis of data. The scale was tested for validity, reliability and responsiveness. Items which were retained included: ascending stairs, rising from sitting, walking on the flat, getting in or out of a car, putting on socks, rising from bed, and sitting. The reduced and full scales had comparable, moderate correlations with other measures of function, confirming convergent validity. Cronbach’s alpha was high (α > 0.85) with the reduced scale confirming reliability. Responsiveness was greater for the reduced scale (full = 1.4, reduced = 1.6). This reduced version of the WOMAC function scale provides a practical, valid, reliable and responsive alternative to the full function scale for use after total joint replacement. Further work is needed to demonstrate its wider applicability


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 923 - 930
1 May 2021
He R Wang Q Wang J Tang J Shen H Zhang X

Aims

As a proven and comprehensive molecular technique, metagenomic next-generation sequencing (mNGS) has shown its potential in the diagnosis of pathogens in patients with periprosthetic joint infection (PJI), using a single type of specimen. However, the optimal use of mNGS in the management of PJI has not been explored. In this study, we evaluated the diagnostic value of mNGS using three types of specimen with the aim of achieving a better choice of specimen for mNGS in these patients.

Methods

In this prospective study, 177 specimens were collected from 59 revision arthroplasties, including periprosthetic tissues, synovial fluid, and prosthetic sonicate fluid. Each specimen was divided into two, one for mNGS and one for culture. The criteria of the Musculoskeletal Infection Society were used to define PJI (40 cases) and aseptic failure (19 cases).


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 681 - 688
1 Apr 2021
Clement ND Hall AJ Kader N Ollivere B Oussedik S Kader DF Deehan DJ Duckworth AD

Aims

The primary aim was to assess the rate of postoperative COVID-19 following hip and knee arthroplasty performed in March 2020 in the UK. The secondary aims were to assess whether there were clinical factors associated with COVID-19 status, the mortality rate of patients with COVID-19, and the rate of potential COVID-19 in patients not presenting to healthcare services.

Methods

A multicentre retrospective study was conducted of patients undergoing hip or knee arthroplasty during the first wave of the COVID-19 pandemic (1 March 2020 to 31 March 2020) with a minimum of 60 days follow-up. Patient demographics, American Society of Anesthesiologists grade, procedure type, primary or revision, length of stay (LOS), COVID-19 test status, and postoperative mortality were recorded. A subgroup of patients (n = 211) who had not presented to healthcare services after discharge were contacted and questioned as to whether they had symptoms of COVID-19.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 347 - 352
1 Feb 2021
Cahan EM Cousins HC Steere JT Segovia NA Miller MD Amanatullah DF

Aims

Surgical costs are a major component of healthcare expenditures in the USA. Intraoperative communication is a key factor contributing to patient outcomes. However, the effectiveness of communication is only partially determined by the surgeon, and understanding how non-surgeon personnel affect intraoperative communication is critical for the development of safe and cost-effective staffing guidelines. Operative efficiency is also dependent on high-functioning teams and can offer a proxy for effective communication in highly standardized procedures like primary total hip and knee arthroplasty. We aimed to evaluate how the composition and dynamics of surgical teams impact operative efficiency during arthroplasty.

Methods

We performed a retrospective review of staff characteristics and operating times for 112 surgeries (70 primary total hip arthroplasties (THAs) and 42 primary total knee arthroplasties (TKAs)) conducted by a single surgeon over a one-year period. Each surgery was evaluated in terms of operative duration, presence of surgeon-preferred staff, and turnover of trainees, nurses, and other non-surgical personnel, controlling cases for body mass index, presence of osteoarthritis, and American Society of Anesthesiologists (ASA) score.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 56 - 64
1 Jan 2021
Podmore B Hutchings A Skinner JA MacGregor AJ van der Meulen J

Aims

Access to joint replacement is being restricted for patients with comorbidities in a number of high-income countries. However, there is little evidence on the impact of comorbidities on outcomes. The purpose of this study was to determine the safety and effectiveness of hip and knee arthroplasty in patients with and without comorbidities.

Methods

In total, 312,079 hip arthroplasty and 328,753 knee arthroplasty patients were included. A total of 11 common comorbidities were identified in administrative hospital records. Safety risks were measured by assessing length of hospital stay (LOS) and 30-day emergency readmissions and mortality. Effectiveness outcomes were changes in Oxford Hip or Knee Scores (OHS/OKS) (scale from 0 (worst) to 48 (best)) and in health-related quality of life (EQ-5D) (scale from 0 (death) to 1 (full health)) from immediately before, to six months after, surgery. Regression analysis was used to estimate adjusted mean differences (LOS, change in OHS/OKS/EQ-5D) and risk differences (readmissions and mortality).


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1682 - 1688
1 Dec 2020
Corona PS Vicente M Carrera L Rodríguez-Pardo D Corró S

Aims

The success rates of two-stage revision arthroplasty for infection have evolved since their early description. The implementation of internationally accepted outcome criteria led to the readjustment of such rates. However, patients who do not undergo reimplantation are usually set aside from these calculations. The aim of this study was to investigate the outcomes of two-stage revision arthroplasty when considering those who do not undergo reimplantation, and to investigate the characteristics of this subgroup.

Methods

A retrospective cohort study was conducted. Patients with chronic hip or knee periprosthetic joint infection (PJI) treated with two-stage revision between January 2010 and October 2018, with a minimum follow-up of one year, were included. Variables including demography, morbidity, microbiology, and outcome were collected. The primary endpoint was the eradication of infection. Patients who did not undergo reimplantation were analyzed in order to characterize this subgroup better.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1271 - 1276
1 Sep 2012
Luyckx T Peeters T Vandenneucker H Victor J Bellemans J

Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an ‘adapted’ measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° . (sd. 2.5) in the gap-balancing group and 1.7° (. sd. 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our ‘adapted’ measured resection technique was much lower than reported in the literature


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 254 - 257
1 Mar 1997
Murray DW Britton AR Bulstrode CJK

Survival analysis of joint replacement relies on the assumption that surgical procedures in patients lost to follow-up have the same chance of failing as those in patients who continue to be assessed. Our study questions that assumption. During the 16-year follow-up of 2268 patients who had received total hip replacements 142 (6%) were lost to follow-up. The cumulative loss at 15 years was 20%. At their last assessment, patients who subsequently failed to attend for follow-up had significantly worse pain, range of movement and opinion of their progress (p < 0.001) and significantly worse radiological features than a matched control group (p < 0.01). Patients lost to follow-up have a worse outcome than those who continue to be assessed. Consequently, a survival analysis that does not take into account such patients is likely to give falsely optimistic results. It is therefore essential that vigorous attempts are made to minimise loss to follow-up, and that the rate of such loss is quoted. The overall loss to follow-up disguises the magnitude of the problem, which is best quantified by a cumulative rate of follow-up. The reliability of a study can be assessed by a loss-to-follow-up quotient, calculated by the number of failures: the lower the quotient the more reliable the data. Ideally, the quotient should be less than 1


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims

The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure.

Patients and Methods

A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims

We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA).

Patients and Methods

We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 218 - 224
1 Feb 2017
Hamilton DF Loth FL Giesinger JM Giesinger K MacDonald DJ Patton JT Simpson AHRW Howie CR

Aims

To validate the English language Forgotten Joint Score-12 (FJS-12) as a tool to evaluate the outcome of hip and knee arthroplasty in a United Kingdom population.

Patients and Methods

All patients undergoing surgery between January and August 2014 were eligible for inclusion. Prospective data were collected from 205 patients undergoing total hip arthroplasty (THA) and 231 patients undergoing total knee arthroplasty (TKA). Outcomes were assessed with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively, then at six and 12 months post-operatively. Internal consistency, convergent validity, effect size, relative validity and ceiling effects were determined.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 201 - 208
1 Feb 2016
Kingsbury SR Dube B Thomas CM Conaghan PG Stone MH

Aims

Increasing demand for total hip and knee arthroplasty (THA/TKA) and associated follow-up has placed huge demands on orthopaedic services. Feasible follow-up mechanisms are therefore essential.

Methods

We conducted an audit of clinical follow-up decision-making for THA/TKA based on questionnaire/radiograph review compared with local practice of Arthroplasty Care Practitioner (ACP)-led outpatient follow-up. In all 599 patients attending an ACP-led THA/TKA follow-up clinic had a pelvic/knee radiograph, completed a pain/function questionnaire and were reviewed by an ACP. An experienced orthopaedic surgeon reviewed the same radiographs and questionnaires, without patient contact or knowledge of the ACP’s decision. Each pathway classified patients into: urgent review, annual monitoring, routine follow-up or discharge.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 799 - 805
1 Jun 2016
McIsaac DI Beaulé PE Bryson GL Van Walraven C

Aims

Total joint arthroplasty (TJA) is commonly performed in elderly patients. Frailty, an aggregate expression of vulnerability, becomes increasingly common with advanced age, and independently predicts adverse outcomes and the use of resources after a variety of non-cardiac surgical procedures. Our aim was to assess the impact of frailty on outcomes after TJA.

Patients and Methods

We analysed the impact of pre-operative frailty on death and the use of resources after elective TJA in a population-based cohort study using linked administrative data from Ontario, Canada.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 923 - 927
1 Jul 2014
Jassim SS Douglas SL Haddad FS

In this systematic review, our aim was to explore whether or not patients are able to return to athletic activity following lower limb joint replacement. We also investigated any evidence as to whether participation in athletic activity post-joint replacement increases complications and reduces implant survival.

A PubMed, Embase and Sports Discus search was performed using the MeSH terms ‘Sport’, ‘Athletic’, ‘Athlete’, ‘Physical’, ‘Activity’, ‘Arthroplasty’, ‘Total Hip Replacement’, ‘Hip Resurfacing’, ‘Total Knee Replacement’, ‘Unicompartmental Knee Replacement’ and ‘Unicondylar Knee Replacement’. From this search, duplications were excluded, the remaining abstracts were reviewed and any unrelated to the search terms were excluded. The remaining abstracts had their full papers reviewed.

Following joint replacement, participation in sporting activity is common principally determined by pre-operative patient activity levels, BMI and patient age. The type of joint replaced is of less significance. Total time spent performing activity does not change but tends to be at a lower intensity. There is little evidence in the literature of an association between high activity levels and early implant failure.

Cite this article: Bone Joint J 2014;96-B:923–7.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1556 - 1561
1 Nov 2013
Irwin A Khan SK Jameson SS Tate RC Copeland C Reed MR

In our department we use an enhanced recovery protocol for joint replacement of the lower limb. This incorporates the use of intravenous tranexamic acid (IVTA; 15 mg/kg) at the induction of anaesthesia. Recently there was a national shortage of IVTA for 18 weeks; during this period all patients received an oral preparation of tranexamic acid (OTA; 25 mg/kg). This retrospective study compares the safety (surgical and medical complications) and efficacy (reduction of transfusion requirements) of OTA and IVTA. During the study period a total of 2698 patients received IVTA and 302 received OTA. After adjusting for a range of patient and surgical factors, the odds ratio (OR) of receiving a blood transfusion was significantly higher with IVTA than with OTA (OR 0.48 (95% confidence interval 0.26 to 0.89), p = 0.019), whereas the safety profile was similar, based on length of stay, rate of readmission, return to theatre, deep infection, stroke, gastrointestinal bleeding, myocardial infarction, pneumonia, deep-vein thrombosis and pulmonary embolism. The financial benefit of OTA is £2.04 for a 70 kg patient; this is amplified when the cost saving associated with significantly fewer blood transfusions is considered.

Although the number of patients in the study is modest, this work supports the use of OTA, and we recommend that a randomised trial be undertaken to compare the different methods of administering tranexamic acid.

Cite this article: Bone Joint J 2013;95-B:1556–61.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 136 - 141
1 Jan 2010
Franken M Grimm B Heyligers I

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value.

Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.