To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications.Aims
Methods
The treatment of late presenting fractures of the lateral humeral
condyle in children remains controversial. We report on the outcome for 16 children who presented with a
fracture of the lateral humeral epicondyle at a mean of 7.4 weeks
(3 to 15.6) after injury and were treated surgically.Aims
Methods
Unstable bicondylar tibial plateau fractures
are rare and there is little guidance in the literature as to the
best form of treatment. We examined the short- to medium-term outcome
of this injury in a consecutive series of patients presenting to
two trauma centres. Between December 2005 and May 2010, a total
of 55 fractures in 54 patients were treated by fixation, 34 with
peri-articular locking plates and 21 with limited access direct
internal fixation in combination with circular external fixation
using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively,
patient-reported outcome measures including the WOMAC index and
SF-36 scores showed functional deficits, although there was no significant
difference between the two forms of treatment. Despite low outcome scores,
patients were generally satisfied with the outcome. We achieved
good clinical and radiological outcomes, with low rates of complication.
In total, only three patients (5%) had collapse of the joint of
>
4 mm, and metaphysis to diaphysis angulation of greater than 5º,
and five patients (9%) with displacement of >
4 mm. All patients
in our study went on to achieve full union. This study highlights the serious nature of this injury and generally
poor patient-reported outcome measures following surgery, despite
treatment by experienced surgeons using modern surgical techniques.
Our findings suggest that treatment of complex bicondylar tibial
plateau fractures with either a locking plate or a TSF gives similar
clinical and radiological outcomes. Cite this article: