Advertisement for orthosearch.org.uk
Results 1 - 20 of 45
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 231 - 238
1 Mar 2023
Holme TJ Crate G Trompeter AJ Monsell FP Bridgens A Gelfer Y

Aims. The ‘pink, pulseless hand’ is often used to describe the clinical situation in which a child with a supracondylar fracture of the humerus has normal distal perfusion in the absence of a palpable peripheral pulse. The management guidelines are based on the assessment of perfusion, which is difficult to undertake and poorly evaluated objectively. The aim of this study was to review the available literature in order to explore the techniques available for the preoperative clinical assessment of perfusion in these patients and to evaluate the clinical implications. Methods. A systematic literature review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered prospectively with the International Prospective Register of Systematic Reviews. Databases were explored in June 2022 with the search terms (pulseless OR dysvascular OR ischaemic OR perfused OR vascular injury) AND supracondylar AND (fracture OR fractures). Results. A total of 573 papers were identified as being suitable for further study, and 25 met the inclusion criteria for detailed analysis. These studies included a total of 504 patients with a perfused, pulseless limb associated with a supracondylar humeral fracture. Clinical examination included skin colour (23 studies (92%)), temperature (16 studies (64%)), and capillary refill time (13 studies (52%)). Other investigations included peripheral oxygen saturation (SaO2) (six studies (24%)), ultrasound (US) (14 (56%)), and CT angiogram (two studies (8.0%)). The parameters of ‘normal perfusion’ were often not objectively defined. The time to surgery ranged from 1.5 to 12 hours. A total of 412 patients (82%) were definitively treated with closed or open reduction and fixation, and 92 (18%) required vascular intervention, ranging from simple release of entrapped vessels to vascular grafts. Conclusion. The description of the vascular assessment of the patient with a supracondylar humeral fracture and a pulseless limb in the literature is variable, with few objective criteria being used to define perfusion. The evidence base for decision-making is limited, and further research is required. We were able, however, to make some recommendations about objective criteria for the assessment of these patients, and we suggest that these are performed frequently to allow the detection of any deterioration of perfusion. Cite this article: Bone Joint J 2023;105-B(3):231–238


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 549 - 558
1 May 2022
Duncumb JW Robinson PG Williamson TR Murray IR Campbell D Molyneux SG Duckworth AD

Aims. The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN). Methods. A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate. Results. There were 78 studies that met the inclusion criteria with a total of 7,671 patients (87.8% male, 12.2% female). The mean age was 27.9 years (SD 3.8) and the mean follow-up was 30.9 months (SD 25.9). The mean union rate was 88.7% (95% confidence interval (CI) 85.0 to 92.5) for non-vascularized grafts versus 87.5% (95% CI 82.8 to 92.2) for vascularized grafts (p = 0.685). Pooled analysis of trial data alone found a mean union rate of 82.4% (95% CI 66.9% to 97.9%) for non-vascularized grafts and 89.4% (95% CI 84.1% to 94.7%) for vascularized grafts (p = 0.780). No significant difference was observed in union rates between any of the fixation techniques used in the studies (p = 0.502). Distal radius and iliac crest graft source had comparable mean union rates (86.9% (95% CI 83.1 to 90.7) vs 87.6% (95% CI 82.2 to 92.9); p = 0.841). Studies that excluded patients with both proximal pole fractures and AVN (n = 14) had a mean union rate of 96.5% (95% CI 94.2 to 98.9) that was significantly greater than the mean union rate of 86.8% (95% CI 83.2 to 90.4) observed in the remaining studies (p < 0.001). Conclusion. Current evidence suggests vascularized bone grafting does not yield significantly superior results to non-vascularized grafting in scaphoid nonunion management. However, potential selection bias lessens the certainty of these findings. The fixation type or source of the graft used was not found to influence union rates either. Sufficiently designed and powered prospective randomized controlled trials in this area are needed. Cite this article: Bone Joint J 2022;104-B(5):549–558


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 21 - 28
1 Jan 2023
Ndlovu S Naqshband M Masunda S Ndlovu K Chettiar K Anugraha A

Aims. Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform interpretation, has poor interobserver reliability, and fails to account for injuries to musculotendinous units and bone. The Ganga Hospital Open Injury Severity Score (GHOISS) was designed to address these concerns. The major aim of this review was to ascertain the evidence available on accuracy of the GHOISS in predicting successful limb salvage in patients with mangled limbs. Methods. We searched electronic data bases including PubMed, CENTRAL, EMBASE, CINAHL, Scopus, and Web of Science to identify studies that employed the GHOISS risk tool in managing complex limb injuries published from April 2006, when the score was introduced, until April 2021. Primary outcome was the measured sensitivity and specificity of the GHOISS risk tool for predicting amputation at a specified threshold score. Secondary outcomes included length of stay, need for plastic surgery, deep infection rate, time to fracture union, and functional outcome measures. Diagnostic test accuracy meta-analysis was performed using a random effects bivariate binomial model. Results. We identified 1,304 records, of which six prospective cohort studies and two retrospective cohort studies evaluating a total of 788 patients were deemed eligible for inclusion. A diagnostic test meta-analysis conducted on five cohort studies, with 474 participants, showed that GHOISS at a threshold score of 14 has a pooled sensitivity of 93.4% (95% confidence interval (CI) 78.4 to 98.2) and a specificity of 95% (95% CI 88.7 to 97.9) for predicting primary or secondary amputations in people with complex lower limb injuries. Conclusion. GHOISS is highly accurate in predicting success of limb salvage, and can inform management and predict secondary outcomes. However, there is a need for high-quality multicentre trials to confirm these findings and investigate the effectiveness of the score in children, and in predicting secondary amputations. Cite this article: Bone Joint J 2023;105-B(1):21–28


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 602 - 609
1 Jun 2023
Mistry D Ahmed U Aujla R Aslam N D’Alessandro P Malik S

Aims. In the UK, the agricultural, military, and construction sectors have stringent rules about the use of hearing protection due to the risk of noise-induced hearing loss. Orthopaedic staff may also be at risk due to the use of power tools. The UK Health and Safety Executive (HSE) have clear standards as to what are deemed acceptable occupational levels of noise on A-weighted and C-weighted scales. The aims of this review were to assess the current evidence on the testing of exposure to noise in orthopaedic operating theatres to see if it exceeds these regulations. Methods. A search of PubMed and EMBASE databases was conducted using PRISMA guidelines. The review was registered prospectively in PROSPERO. Studies which assessed the exposure to noise for orthopaedic staff in operating theatres were included. Data about the exposure to noise were extracted from these studies and compared with the A-weighted and C-weighted acceptable levels described in the HSE regulations. Results. A total of 15 studies were deemed eligible. These included a total of 386 orthopaedic operations and the use of 64 orthopaedic instruments. A total of 294 operations (76%) and 45 instruments (70%) exceeded the regulations on an A-weighted scale, and 22% (10 of 46) of operations exceeded the maximum C-weighted peak acceptable level of noise. Noise-induced hearing loss was reported in 28 of 55 orthopaedic staff members (50.9%). Conclusion. Safe levels of noise can be exceeded in orthopaedic operations, and when using orthopaedic instruments. Employers have clear policies about exposure to noise in the workplace but have yet to identify orthopaedic theatres as a potential at-risk area. Orthopaedic staff need education, monitoring, and protection, while employers should consider regular assessments of staff in orthopaedic theatres and offer methods to prevent noise-induced hearing loss. Cite this article: Bone Joint J 2023;105-B(6):602–609


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1457 - 1466
2 Nov 2020
Cha Y Yoo J Kim J Park C Ahn Y Choy W Ha Y Koo K

Aims. To evaluate the rate of dislocation following dual mobility total hip arthroplasty (DM-THA) in patients with displaced femoral neck fractures, and to compare rates of dislocation, surgical-site infection, reoperation, and one-year mortality between DM-THA and bipolar hemiarthroplasty (BHA). Methods. Studies were selected based on the following criteria: 1) study design (retrospective cohort studies, prospective cohort studies, retrospective comparative studies, prospective comparative studies, and randomized controlled studies (RCTs)); 2) study population (patients with femoral neck fracture); 3) intervention (DM-THA or BHA); and 4) outcomes (complications during postoperative follow-up and clinical results). Pooled meta-analysis was carried out to evaluate the dislocation rate after DM-THA and to compare outcomes between DM-THA and BHA. Results. A total of 17 studies (ten cohort studies on DM-THA and seven comparative studies of DM-THA and BHA) were selected. These studies included 2,793 patients (2,799 hips), made up of 2,263 DM-THA patients (2,269 hips) and 530 BHA patients (530 hips). In all, 16 studies were analyzed to evaluate dislocation rate after DM-THA. The cumulative dislocation rate was 4% (95% confidence interval (CI) 3 to 5). Seven studies were analyzed to compare the rates dislocation and surgical-site infection. The rate of dislocation was significantly lower in the DM-THA group than in the BHA group (risk ratio (RR) 0.3; 95% CI 0.17 to 0.53, p < 0.001, Z −4.11). There was no significant difference in the rate of surgical-site infection between the two groups (p = 0.580). Six studies reported all-cause reoperations. The rate of reoperation was significantly lower in the DM-THA group than in the BHA group (RR 0.5; 95% CI 0.32 to 0.78, p = 0.003, Z −3.01). Five studies reported one-year mortality. The mortality rate was significantly lower in the DM-THA group than in the BHA group (RR 0.58 95% CI 0.45 to 0.75, p < 0.0001, Z −4.2). Conclusion. While the evidence available consisted mainly of non-randomized studies, DM-THA appeared to be a viable option for patients with displaced fractures of the femoral neck, with better reported rates of dislocation, reoperation, and mortality than BHA. Cite this article: Bone Joint J 2020;102-B(11):1457–1466


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 487 - 495
1 May 2023
Boktor J Wong F Joseph VM Alshahwani A Banerjee P Morris K Lewis PM Ahuja S

Aims

The early diagnosis of cauda equina syndrome (CES) is crucial for a favourable outcome. Several studies have reported the use of an ultrasound scan of the bladder as an adjunct to assess the minimum post-void residual volume of urine (mPVR). However, variable mPVR values have been proposed as a threshold without consensus on a value for predicting CES among patients with relevant symptoms and signs. The aim of this study was to perform a meta-analysis and systematic review of the published evidence to identify a threshold mPVR value which would provide the highest diagnostic accuracy in patients in whom the diagnosis of CES is suspected.

Methods

The search strategy used electronic databases (PubMed, Medline, EMBASE, and AMED) for publications between January 1996 and November 2021. All studies that reported mPVR in patients in whom the diagnosis of CES was suspected, followed by MRI, were included.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1292 - 1303
1 Dec 2022
Polisetty TS Jain S Pang M Karnuta JM Vigdorchik JM Nawabi DH Wyles CC Ramkumar PN

Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered.

Cite this article: Bone Joint J 2022;104-B(12):1292–1303.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 247 - 253
1 Mar 2023
Pakarinen O Ponkilainen V Uimonen M Haapanen M Helenius I Kuitunen I

Aims

To analyze whether the addition of risk-based criteria to clinical examination-based selective ultrasound screening would increase the rates of early detected cases of developmental dysplasia of the hip (DDH) and decrease the rate of late detected cases.

Methods

A systematic review with meta-analysis was performed. The initial search was performed in the PubMed, Scopus, and Web of Science databases in November 2021. The following search terms were used: (hip) AND (ultrasound) AND (luxation or dysplasia) AND (newborn or neonate or congenital).


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1038 - 1044
1 Oct 2023
Walton TJ Huntley D Whitehouse SL Davies J Wilson MJ Hubble MJW Howell JR Kassam AM

Aims

The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision hip arthroplasty, and specifically to analyze the available data in order to quantify any associated reduction in the use of allogenic blood transfusion, and the volume which is used.

Methods

An electronic search of MEDLINE (PubMed), Embase, Scopus, and the Cochrane Library was completed from the date of their inception to 24 February 2022, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were patients aged > 18 years who underwent revision hip arthroplasty when cell salvage was used. Studies in which pre-donated red blood cells were used were excluded. A meta-analysis was also performed using a random effects model with significance set at p = 0.05.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 121 - 127
1 Feb 2024
Filtes P Sobol K Lin C Anil U Roberts T Pargas-Colina C Castañeda P

Aims

Perthes' disease (PD) is a relatively rare syndrome of idiopathic osteonecrosis of the proximal femoral epiphysis. Treatment for Perthes' disease is controversial due to the many options available, with no clear superiority of one treatment over another. Despite having few evidence-based approaches, many patients with Perthes' disease are managed surgically. Positive outcome reporting, defined as reporting a study variable producing statistically significant positive (beneficial) results, is a phenomenon that can be considered a proxy for the strength of science. This study aims to conduct a systematic literature review with the hypothesis that positive outcome reporting is frequent in studies on the treatment of Perthes' disease.

Methods

We conducted a systematic review of all available abstracts associated with manuscripts in English or with English translation between January 2000 and December 2021, dealing with the treatment of Perthes' disease. Data collection included various study characteristics, surgical versus non-surgical management, treatment modality, mean follow-up time, analysis methods, and clinical recommendations.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1140 - 1148
1 Nov 2023
Liukkonen R Vaajala M Mattila VM Reito A

Aims

The aim of this study was to report the pooled prevalence of post-traumatic osteoarthritis (PTOA) and examine whether the risk of developing PTOA after anterior cruciate ligament (ACL) injury has decreased in recent decades.

Methods

The PubMed and Web of Science databases were searched from 1 January 1980 to 11 May 2022. Patient series, observational studies, and clinical trials having reported the prevalence of radiologically confirmed PTOA after ACL injury, with at least a ten-year follow-up, were included. All studies were analyzed simultaneously, and separate analyses of the operative and nonoperative knees were performed. The prevalence of PTOA was calculated separately for each study, and pooled prevalence was reported with 95% confidence intervals (CIs) using either a fixed or random effects model. To examine the effect of the year of injury on the prevalence, a logit transformed meta-regression analysis was used with a maximum-likelihood estimator. Results from meta-regression analyses were reported with the unstandardized coefficient (β).


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 857 - 863
1 Aug 2023
Morgan C Li L Kasetti PR Varma R Liddle AD

Aims

As an increasing number of female surgeons are choosing orthopaedics, it is important to recognize the impact of pregnancy within this cohort. The aim of this review was to examine common themes and data surrounding pregnancy, parenthood, and fertility within orthopaedics.

Methods

A systematic review was conducted by searching Medline, Emcare, Embase, PsycINFO, OrthoSearch, and the Cochrane Library in November 2022. The Preferred Reporting Items for Systematic Reviews and Meta Analysis were adhered to. Original research papers that focused on pregnancy and/or parenthood within orthopaedic surgery were included for review.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 239 - 246
1 Mar 2023
Arshad Z Aslam A Al Shdefat S Khan R Jamil O Bhatia M

Aims

This systematic review aimed to summarize the full range of complications reported following ankle arthroscopy and the frequency at which they occur.

Methods

A computer-based search was performed in PubMed, Embase, Emcare, and ISI Web of Science. Two-stage title/abstract and full-text screening was performed independently by two reviewers. English-language original research studies reporting perioperative complications in a cohort of at least ten patients undergoing ankle arthroscopy were included. Complications were pooled across included studies in order to derive an overall complication rate. Quality assessment was performed using the Oxford Centre for Evidence-Based Medicine levels of evidence classification.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 7 - 15
1 Jan 2021
Farhan-Alanie MM Burnand HG Whitehouse MR

Aims. This study aimed to compare the effect of antibiotic-loaded bone cement (ALBC) versus plain bone cement (PBC) on revision rates for periprosthetic joint infection (PJI) and all-cause revisions following primary elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). Methods. MEDLINE, Embase, Web of Science, and Cochrane databases were systematically searched for studies comparing ALBC versus PBC, reporting on revision rates for PJI or all-cause revision following primary elective THA or TKA. A random-effects meta-analysis was performed. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID CRD42018107691). Results. Nine studies and one registry report were identified, enabling the inclusion of 371,977 THA and 671,246 TKA. Pooled analysis for THA demonstrated ALBC was protective against revision for PJI compared with PBC (relative risk (RR) 0.66, 95% confidence interval (CI) 0.56 to 0.77; p < 0.001), however, no differences were seen for all-cause revision rate (RR 0.62, 95% CI 0.35 to 1.09; p = 0.100). For TKA, there were no significant differences in revision rates for PJI or all causes between ALBC and PBC (RR 0.92, 95% CI 0.59 to 1.45; p = 0.730, and RR 0.73, 95% CI 0.53 to 1.02; p = 0.060, respectively). Conclusion. ALBC demonstrated a protective effect against revision for PJI compared with PBC in THA with no difference in all-cause revisions. No differences in revision rates for PJI and all-cause revision between ALBC and PBC for TKA were observed. Cite this article: Bone Joint J 2021;103-B(1):7–15


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims

This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA).

Methods

Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims

The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI.

Methods

We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified.


Aims

The aim of this study was to review the current evidence surrounding curve type and morphology on curve progression risk in adolescent idiopathic scoliosis (AIS).

Methods

A comprehensive search was conducted by two independent reviewers on PubMed, Embase, Medline, and Web of Science to obtain all published information on morphological predictors of AIS progression. Search items included ‘adolescent idiopathic scoliosis’, ‘progression’, and ‘imaging’. The inclusion and exclusion criteria were carefully defined. Risk of bias of studies was assessed with the Quality in Prognostic Studies tool, and level of evidence for each predictor was rated with the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach. In all, 6,286 publications were identified with 3,598 being subjected to secondary scrutiny. Ultimately, 26 publications (25 datasets) were included in this review.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 567 - 574
2 May 2022
Borton ZM Oakley BJ Clamp JA Birch NC Bateman AH

Aims

Cervical radiculopathy is a significant cause of pain and morbidity. For patients with severe and poorly controlled symptoms who may not be candidates for surgical management, treatment with transforaminal epidural steroid injections (CTFESI) has gained widespread acceptance. However, a paucity of high-quality evidence supporting their use balanced against perceived high risks of the procedure potentially undermines the confidence of clinicians who use the technique. We undertook a systematic review of the available literature regarding CTFESI to assess the clinical efficacy and complication rates of the procedure.

Methods

OVID, MEDLINE, and Embase database searches were performed independently by two authors who subsequently completed title, abstract, and full-text screening for inclusion against set criteria. Clinical outcomes and complication data were extracted, and a narrative synthesis presented.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 416 - 423
1 Apr 2022
Mourkus H Phillips NJ Rangan A Peach CA

Aims

The aim of this study was to investigate the outcome of periprosthetic fractures of the humerus and to assess the uniformity of the classifications used for these fractures (including those around elbow and/or shoulder arthroplasties) by performing a systematic review of the literature.

Methods

A systematic search was conducted using the National Institute for Health and Care Excellence Healthcare Databases Advance Search. For inclusion, studies had to report clinical outcomes following the management of periprosthetic fractures of the humerus. The protocol was registered on the PROSPERO database.